• Title/Summary/Keyword: Long vehicle tunnel

Search Result 38, Processing Time 0.03 seconds

Worldwide Trends in the Research Topics for the Vehicle Tunnel Ventilation (도로터널 환기관련 연구동향)

  • 이창우
    • Tunnel and Underground Space
    • /
    • v.12 no.3
    • /
    • pp.152-157
    • /
    • 2002
  • Optimal design of the long tunnels with large cross sections essential for the effective development of the limited land in Korea becomes more and more difficult owing to the constantly changing social, economic, environmental and technological factors. Deficiency of the domestic research works till now on the elementary topics on tunnel ventilation retards progress on developing the key technologies urgently required for designing and managing the long and large tunnels. This paper aims at identifying the subjects on which research must be carried out for the construction and management of vehicle tunnels in Korea by means of scrutinizing the contents of the publications since 1991 at the International Symposium on Aerodynamic and Ventilation of Vehicle Tunnels, the only international conference on the tunnel ventilation.

Flow Analysis Using 1 and 3 Dimensional Hybrid Mesh For Ultra-High Speed Vehicle Inside A Long Distance Tunnel (1-3차원 혼합격자를 이용한 장거리 터널 내 고속 운송체 유동해석)

  • Kim, Tae-Kyung;Choi, Joong-Keun;Kwon, Hyeok-Bin;Kim, Kyu-Hong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.107-118
    • /
    • 2011
  • This paper performs flow analysis of ultra-high speed vehicle inside the long distance tunnel. One and three dimensional hybrid mesh was used for describing moving motion and flow analysis of an vehicle inside a long distance tunnel which over 20 km. Flow analysis and aerodynamic drag measuring were performed by three dimensional mesh: around vehicle, and pressure waves of a tunnel was measured by one dimensional mesh: the other region where rare changing of flow pattern.

  • PDF

Development of 1-3 Dimensional Hybrid Mesh Method for Flow Analysis of the Ultra-High Speed Vehicle Inside a Long Distance Tunnel (장거리 터널 내 고속 운송체의 유동 해석을 위한 1-3차원 혼합격자 기법개발)

  • Choi, Joong-Keun;Kim, Tae-Kyung;Kwon, Hyeok-Bin;Kim, Kyu-Hong
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.119-127
    • /
    • 2011
  • This paper shows development of 1-3 dimensional hybrid mesh method to analysis flow induced by ultra-high speed vehicle inside a long distance tunnel. For three-dimensional analysis of the tunnel system many meshes are required. However it is not efficient to calculate the whole tunnel system in three-dimension. Therefore in this paper, three-dimension meshes was used to describe stations, shafts and around vehicle, and one-dimension meshes was used to describe the tunnel except these three sections. And unsteady flow analysis of the ultra-high speed vehicle was performed with UDFs in commercial software, Ansys vr. 12.0.

  • PDF

A Numerical Analysis of Hydrogen Diffusion for Hydrogen Leakage from a Fuel Cell Vehicle in a Long Road Tunnel (장대터널에서 수소연료전지 차량의 수소 누출에 대한 수소 거동의 수치해석 연구)

  • Choi, Jongrak;Hur, Nahmkeon;Lee, Moonkyu;Chang, Hyungjin;Lee, Kwangbum;Yong, Geejoong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.588-597
    • /
    • 2012
  • In the present study, the dispersion characteristics of hydrogen leakage from a Fuel Cell Vehicle (FCV) were analyzed by numerical simulation in order to assess the risk of a hydrogen leakage incident in a long road tunnel. In order to implement the worst case of hydrogen leakage, the FCV was located at the center of a tunnel, and hydrogen was completely discharged within 63 seconds. The Leakage velocity of hydrogen was adopted sub-sonic speed because that the assumption of the blockage effect of secondary device inside a vehicle. The temporal and spatial evaluation of the hydrogen concentration as well as the flammable region in a road tunnel was reported according to change of ventilation operating conditions. The hydrogen was blended by supply air form a ventilation fan, however, the hydrogen was discharged to outside in the exhaust air. It is observed that the efficiency way to eliminate of hydrogen is supply air operating condition under the hazardous hydrogen leaking incident. The present numerical analysis can be provided useful information of ventilation under the hydrogen leaking situation.

The Way for improvement of facility to strengthen accessibility of the site for fire department (소방대의 현장접근성 강화를 위한 설비의 개선방안)

  • Oh, Taek-Hum;Sung, Ja-Man;Pak, Chan-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

The study on the operation of fire fighting vehicle for a long railway tunnel (장대터널용 소방차량의 운용에 관한 연구)

  • Kwon, Tae-Soon;Park, Won-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.516-521
    • /
    • 2016
  • In this study, we investigated the operation of railroad fire fighting vehicles against fires on trains in a long railway tunnel. In recent years, long railway tunnels (more than 10 km in length) have been built and the number of such tunnels, such as the Geumjeong tunnel (20.3 km in length) on the Gyeongbu high speed line, Solan tunnel (16.7 km in length) on the Yeongdong line and Yulhyeon tunnel (50.3 km in length) on the Suseo high speed line which is scheduled to be opened in the second half of 2016, is increasing. Significant damage is to be expected, due to the increased evacuation time and limited accessibility of fire services when the train is stopped by an urgent fire in the tunnel. Special fire fighting vehicles capable of running on rails have been developed and operated in overseas advanced countries. Therefore, a fire-response system using Unimog vehicles, which can run on road and rail, instead of road vehicles, is necessary. The characteristics of the railway tunnel and thermal environmental change caused by a train fire in a tunnel were analyzed in this study. Also, the operational requirements of the railroad fire fighting vehicles were evaluated by taking into account the specifications of the railroad fire fighting vehicles under development.

A case study for prediction of the natural ventilation force in a local long vehicle tunnel (장대도로터널의 자연환기력 예측 사례연구)

  • Lee, Chang-Woo;Kim, Sang-Hyun;Gil, Se-Won;Cho, Woo-Chul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.395-401
    • /
    • 2009
  • One of the key design factors for the ventilation and safety system at extra long tunnel is the airflow velocity induced by the natural ventilation force. Despite of the importance, it has not been widely studied due to the complicated influencing variables and the relationship among them is difficult to quantify. At this moment none of the countries in the world defines its specific value on verified ground. It is also the case in Korea. The recent worldwide disasters by tunnel fires and demands for better air quality inside tunnel by users require the optimization of the tunnel ventilation system. This indicates why the natural ventilation force is necessary to be thoroughly studied. This paper aims at predicting the natural ventilation force at a 11 km-long tunnel which is in the stage of detailed design and will be the longest vehicle tunnel in Korea. The concept of barometric barrier which can provide the maximum possible natural ventilation force generated by the topographic effect on the external wind is applied to estimate the effect of wind pressure and the chimney effect caused by the in and outside temperature difference is also analyzed.

A Study on the Principal Factors of Rail Tunnel Cross-Section Design due to High Speed (고속화에 따른 철도터널의 단면규모 결정요소에 대한 고찰)

  • Ryu, Dong-Hun;Lee, Hyeon-Jeong;Han, Sang-Yeon;Shin, Hyon-Il;Jung, Byung-Ryul;Song, Chung-Ryul
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1487-1501
    • /
    • 2011
  • Recently, fast-growing up railway transportations. Because, regional traffic congestion problem solving and a period of rapid expansion to meet the demand of industries. In addition the government also suggest to new paradigm for the future 'Low Carbon, Green Growth' is presented as a new national vision. To meet the social needs and the time demands, Last of the railway increase very long tunnels and huge deep tunnels. Especially this trend accelerated high speed up in the tunnel, the revision of design criteria and research challenges are being actively improved. Mainly in the tunnel cross-section was under the control of the vehicle train speed 150km/hr by the construction of the vehicle cross-section of the tunnel. More than 200km/hr rail tunnel depending on the vehicle's speed caused the tunnel to the pressure fluctuations will be governed by the aerodynamic changes. Considering the economy to ensure the optimum cross-section of the railway tunnel to the description scheme is selected cross-section of the railway tunnel to determine the size domestic or international railway tunnel for the elements((based on fast Algorithm design criteria, the center line spacing, streetcar line, cross-sectional shape, sectoral issues, such as interface and aerodynamics) based on design practices and to review results. In this study, to propose guidelines depending on the size of a railway tunnel cross section for the size of the determining reasonable factors when designing the railway tunnel and cost-effective standards guidelines.

  • PDF

A Case Study for the 1st Double-level Tunnel for Light vehicle in Urban Area in Korea (국내 최초 소형차 전용 도심지 대심도 복층터널 설계 사례)

  • Kim, Gyoung-Hun;Choi, Jun-Dong;Jun, Duk-Chan;Shin, Il-Jae;Sim, Dong-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1302-1313
    • /
    • 2010
  • The west express way is notorious for extremely heavy traffic area in the west of Seoul, South Korea. Hence, the city government recently initiated a new underground BTO (Build-Transfer-Operate) road project to solve traffic congestion and a high construction cost. The proposed underground express road being designed is the first double-level tunnel ever designed in South Korea and using Conventional tunnelling method (NATM). A total length of tunnel for light vehicles is 10.91km long including both open cut structures and concrete lining with middle-deck in bored tunnel. There are also 4 ventilation shafts for ventilation and evacuation on emergency. Many design issues had been aroused during the preliminary design phase and detail design phase is currently going on. This paper discusses design focuses including excavation methods, ground water issues, a deck slab installation, and a construction cost etc. for the double level road tunnel design of urban area.

  • PDF

Experimental Study on the Interval of Emergency Exits in Long Traffic Tunnels (장대 교통터널의 피난연락갱 설치 간격에 관한 실험적 연구)

  • Yoo Yongho;Yoon Sungwook;Kim Jin;Yoon Chanhoon
    • Tunnel and Underground Space
    • /
    • v.15 no.1 s.54
    • /
    • pp.61-70
    • /
    • 2005
  • The objective of this study was to analyze the smoke movement for the case of fire and to determine the interval between emergency exits in long tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was constructed by acrylic tubes and tests were carried out systematically. From the strong relationship between CO propagation time and distance through the tunnel, it was found that the optimal escaping time was 6 minutes in case of 20MW fire. But, regarding passengers' psychological state under fire, another one minute of delay time should be considered. Therefore, the total escaping time should be estimated by 5 minutes. The interval between the emergency exits for vehicle passengers was calculated by 250 m with respect to the 5 minute of escaping time.