• 제목/요약/키워드: Long pulse

검색결과 444건 처리시간 0.024초

Monitoring of a CFRP-Stiffened Panel Manufactured by VaRTM Using Fiber-Optic Sensors

  • Takeda, Shin-Ichi;Mizutani, Tadahito;Nishi, Takafumi;Uota, Naoki;Hirano, Yoshiyasu;Iwahori, Yutaka;Nagao, Yosuke;Takeda, Nobuo
    • Advanced Composite Materials
    • /
    • 제17권2호
    • /
    • pp.125-137
    • /
    • 2008
  • FBG (Fiber Bragg Grating) sensors and optical fibers were embedded into CFRP dry preforms before resin impregnation in VaRTM (Vacuum-assisted Resin Transfer Molding). The embedding location was the interface between the skin and the stringer in a CFRP-stiffened panel. The reflection spectra of the FBG sensors monitored the strain and temperature changes during all the molding processes. The internal residual strains of the CFRP panel could be evaluated during both the curing time and the post-curing time. The temperature changes indicated the differences between the dry preform and the outside of the vacuum bagging. After the molding, four-point bending was applied to the panel for the verification of its structural integrity and the sensor capabilities. The optical fibers were then used for the newly-developed PPP-BOTDA (Pulse-PrePump Brillouin Optical Time Domain Analysis) system. The long-range distributed strain and temperature can be measured by this system, whose spatial resolution is 100 mm. The strain changes from the FBGs and the PPP-BOTDA agreed well with those from the conventional strain gages and FE analysis in the CFRP panel. Therefore, the fiber-optic sensors and its system were very effective for the evaluation of the VaRTM composite structures.

Effects of Paroxetine on a Human Ether-a-go-go-related Gene (hERG) K+ Channel Expressed in Xenopus Oocytes and on Cardiac Action Potential

  • Hong, Hee-Kyung;Hwang, Soobeen;Jo, Su-Hyun
    • International Journal of Oral Biology
    • /
    • 제43권1호
    • /
    • pp.43-51
    • /
    • 2018
  • $K^+$ channels are key components of the primary and secondary basolateral $Cl^-$ pump systems, which are important for secretion from the salivary glands. Paroxetine is a selective serotonin reuptake inhibitor (SSRI) for psychiatric disorders that can induce QT prolongation, which may lead to torsades de pointes. We studied the effects of paroxetine on a human $K^+$ channel, human ether-a-go-go-related gene (hERG), expressed in Xenopus oocytes and on action potential in guinea pig ventricular myocytes. The hERG encodes the pore-forming subunits of the rapidly-activating delayed rectifier $K^+$ channel ($I_{Kr}$) in the heart. Mutations in hERG reduce $I_{Kr}$ and cause type 2 long QT syndrome (LQT2), a disorder that predisposes individuals to life-threatening arrhythmias. Paroxetine induced concentration-dependent decreases in the current amplitude at the end of the voltage steps and hERG tail currents. The inhibition was concentration-dependent and time-dependent, but voltage-independent during each voltage pulse. In guinea pig ventricular myocytes held at $36^{\circ}C$, treatment with $0.4{\mu}M$ paroxetine for 5 min decreased the action potential duration at 90% of repolarization ($APD_{90}$) by 4.3%. Our results suggest that paroxetine is a blocker of the hERG channels, providing a molecular mechanism for the arrhythmogenic side effects of clinical administration of paroxetine.

최소자승법을 이용한 다수 베타 방출 핵종 혼합물의 방사능 분석 (Radioassay of Multiple Beta-Labeled Mixtures using Least-Square Method)

  • 선광일;남욱원;공경남;김창규;이동명;이상국
    • Journal of Radiation Protection and Research
    • /
    • 제26권4호
    • /
    • pp.375-384
    • /
    • 2001
  • 베타선 스펙트럼의 최대 에너지가 확실하게 구별되는 2개의 핵종만을 포함하는 혼합시료의 경우에는 최대 에너지가 다르다는 점을 이용하여 손쉽게 각 핵종의 방사능 값을 측정할 수 있다. 그러나 3개 이상의 베타 방출 핵종이 포함된 혼합물에 대해서는 각 핵종의 스펙트럼이 서로 겹치기 때문에 이러한 방법으로 구해진 방사능 값은 신뢰도가 떨어지게 된다. 따라서, 본 연구에서는 최소자승법을 이용하여 혼합물의 중첩된 베타선 스펙트럼을 각각 분리 정량분석 할 수 있는 방법을 제시하였다. 또한, 실제로 4개의 베타 방출 핵종($^3H,\;^{14}C,\;^{36}Cl\;^{90}Sr$)이 혼합된 시료를 조제하여 본 분석법을 검증한 결과 참고치(Reference value)와 분석치가 7% 이내에서 잘 일치함을 보였다.

  • PDF

고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향 (Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique)

  • 조승연;김태희;장인성;홍웅기;이준호
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

스위치 캐패시터형 공진 DC-링크를 사용한 3상 전류형 소프트 스위칭 PWM 컨버터 (Three-phase current-fed soft-switching type resonant DC-link snubber converter with switched capacitor)

  • 김주용;서기영;이현우;문상필;김영문
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2005
  • A This paper presents a novel three-phase current-fed Pulse Width Modulation converter with switched- capacitor type resonant DC link commutation circuit operating PWM pattern strategy under a design consideration of low-pass filter, which can operate on the basis of the principle of zero current soft-switching commutation. In the first place, the steady-state operating principle of this converter with a new resonant DC link snubber circuit is described in connection with the equivalent operation circuit, together with the practical design procedure of the switched-capacitor type resonant DC link circuit is discussed from a theoretical viewpoint on the basis of a design example for high-power applications. The actively delayed time correction method to compensate distorted currents due to a relatively long resonant commutation time is newly implemented in the open loop control scheme so as to acquire the new optimum PWM pattern. Finally, the experiment or set-up in laboratory system or this converter is concretely demonstrated herein to confirm a zero current soft-switching commutation of this converter. The comparative evaluations between current-fed hard switching PWM and soft-switching PWM converters are carried out from a viewpoint of their PWM converter characteristics.

  • PDF

$SF_{6}$가스와 절연지의 절연계에서 가스압력에 따른 부분방전 현상(II) (Partial Discharge Phenomena with $SF_{6}$ Gas Pressures in Insulation Consisted of Insulation Paper and $SF_{6}$ Gas(II))

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권9호
    • /
    • pp.430-435
    • /
    • 2002
  • The $SF_{6}$ gas insulated power equipments have the insulation systems which are composed of $SF_{6}$ gas and insulation paper. It is repored that their insulation abilities are influenced by the $SF_{6}$ gas gaps in those insulation systems and gas pressures. This paper describes partial discharge phenomena with $SF_{6}$ gas pressures in insulation system of $SF_{6}$ gas-insulation paper Specimens of $SF_{6}$ gas-insulation paper were prepared and aramid paper was used as insulation paper. Partial discharge inception voltages(PDIV) and breakdown voltages for the existence of $SF_{6}$ gas gaps were measured by short term tests with gas pressures. Also, average PD quantities and pulse counts, life times of each specimens were calculated from the results of long term aging tests with gas pressures. It was found that the $SF_{6}$ gas gaps decrease increasing rates of PDIV and brealdown voltages according to gas pressure increase and the insulation breakdown caused by the smaller PD quantities than 1[pC] at the high gas pressure of 300kPa is due to the increase of energy density with increase of gas pressure.

사춘기 조숙증의 기전 및 치료의 최신 지견 (Recent Advance in Pathogenesis and Treatment of Precocious Precocity)

  • 박미정
    • 한국발생생물학회지:발생과생식
    • /
    • 제10권4호
    • /
    • pp.215-225
    • /
    • 2006
  • 사춘기 조숙증은 여아에서 8세 이전에 유방 발육이 있거나 남아에서 9세 이전에 고환이 4 mL 이상 커지는 것으로 정의되는데 최근 사춘기 발현 연령이 점차 낮아지고 있다. 사춘기를 시작하는 gonadotrophin releasing hormone(GnRH)의 활성화에는 흥분성 및 억제성 아미노산, 성장인자, 전사조절인자, 아디포카인 등 많은 인자들이 복합적으로 작용한다. 특발성 사춘기 조숙증의 원인으로서 유전인자, 영양상태(특히 체지방 증가), 환경호르몬 노출 등 여러 가지 원인이 추정되고 있다. 사춘기 조숙증은 정서적 스트레스뿐 아니라 성장판의 조기폐쇄로 인한 저신장을 초래할 수 있다. 사춘기 조숙증은 진성 성조숙증과 가성 성조숙증으로 분류할 수 있으며 gonadotrophin이 활성화되는 진성 성조숙증에서는 적절한 시기에 GnRH 길항제를 치료하였을 때 사춘기 지연 및 최종 성인 신장을 호전시키는 것으로 보고되고 있으나 그 효과 및 장기적 부작용에 대해서는 좀더 연구가 필요하리라 사료된다.

  • PDF

복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구 (A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography)

  • 김정민;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

폐동맥-쇄골하동맥 문합시의 폐동맥 변화에 관한 실험적 연구 (Pulmonary Vascular Changes in Systemic Pulmonary Anastomosis:An Experimental Study)

  • 박영관
    • Journal of Chest Surgery
    • /
    • 제3권2호
    • /
    • pp.91-106
    • /
    • 1970
  • Two groups of left pulmonary-subclavian artery anastomosis were done in 26 adult mongorel dogs. For the first group. the distal end of the subclnvian artery was nnastomosed to the side of the left pulmonary artery, and for the second group, the subclavian end wns anastomosed to the proximal end of the left lower lobe pulmonary artery. Among them, 6 died of bleeding or anesthetic failure during the day of operation, 10 survived 1 to 106 days and the other 10 were sacrificed at various interval. To investigate the relationship between hemodynamic stress and temporal evolution of the pulmonary vascular lesions. the pulmona try and femoral artery pressures, arteriogram and pathohistological specimens were obtained. The following results were obtained. 1. The postoperative pulmonary artery pressures were within normal limits except 2 dogs in the first group, but in nil 12 dogs of the second group, they were in moderate to maked pulmonary hypertension level. 2 After subclavian pulmonary anastomosis, both groups dogs showed increased femond artery pulse pressure. 3. The pulmonary vascular changes were more severe and appeared earlier in the second group dogs compared with the first group.4. The earliest vascular changes appeared in the media of the small muscular arteries and arterioles. 5. Various vascular chaDges were produced in 2 or 3 months. Thereafter, the changes were stationary. 6. Among the first group, two long-term servivors (No. 705 & 713) which had normal pulmonary artery pressure under the anesthesia, also showed various vascular changes as other pulmonary hypertensive dogs. 7. In the early stage medial hypertrophy. interruptio~l of elastic lamellae were found in the small muscular arteries and arterioles, which were followed by intimal proliferation and thrombosis. These findings may suggest some evidences of trauma to the vessels. 8. Pulmonary arteriograms showed irregularity of the intima of the large and medium sized arteries, abrupt ending of some of the small arteries and narrowing of the anastomosis.

  • PDF

저 준위 액체섬광계수기를 이용한 섬광체 종류에 따른 222Rn 농도 변화 연구 (Study on Concentration Variation of 222Rn for Various Scintillators Using Low-Level Liquid Scintillation Counter)

  • 전재완;이득희;김진섭
    • 한국방사선학회논문지
    • /
    • 제13권6호
    • /
    • pp.847-856
    • /
    • 2019
  • 오늘날 경제의 발전과 함께 여러 가지 환경 문제가 발생했다. 자연스레 사람들은 환경에 대한 관심이 높아졌으며 특히 식수에 대한 안전성과 오염도 조사에 대한 중요성이 부각되고 있다. 우리나라 국민들이 식수로 이용하는 지하수에서 우라늄 및 222Rn 이 다수 지역에서 검출되고 있다. 따라서 이 연구는 지하수 내포함된 222Rn 농도를 측정하는데 보다 정확한 측정을 위한 방법을 알아보고자 한다. 실험은 알파, 베타 펄스의 분석이 용이한 펄스파형분석 기능을 가진 저 준위 액체섬광계수기를 이용하여 실험하였다. 지하수 시료와 혼합하는 섬광체의 조제, 유효기간은 시간이 지날수록 검출값은 낮아지고, 에너지 스펙트럼도 낮은 쪽으로 channel 이동이 있었다. 섬광체의 구입시기가 오래 될수록, 개봉한 후 방치시간이 지날수록 검출값이 낮아짐을 확인했다. 사용목적이 다른 섬광체를 사용했을 경우 channel 이동으로 에너지를 확인할 수 있다.