• Title/Summary/Keyword: Long endurance

Search Result 201, Processing Time 0.022 seconds

A Study on the Development of Low-Altitude and Long-Endurance Solar-Powered UAV from Korea Aerospace University (2) - Flight Control and Guidance of Solar Powered UAV - (한국항공대학교 저고도 장기체공 태양광 무인기 개발에 관한 연구 (2) - 태양광 무인기 비행제어 및 유도항법 -)

  • Kim, Taerim;Kim, Doyoung;Jeong, Jaebaek;Moon, Seokmin;Kim, Yongrae;Bae, Jae-Sung;Park, Sanghyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.7
    • /
    • pp.479-487
    • /
    • 2022
  • This paper presents the control and guidance algorithm of a KAU-SPUAV(Korea Aerospace University - Solar Powered Unmanned Aerial Vehicle) which is designed and developed in Korea Aerospace University. Aerodynamic coefficients are calculated using the vortex-lattice method and applied to the aircraft's six degrees of freedom equation. In addition, the thrust and torque coefficients of the propeller are calculated using the blade element theory. An altitude controller using thrust was used for longitudinal control of KAU-SPUAV to glide efficiently when it comes across the upwind. Also describes wind estimation technic for considering wind effect during flight. Finally, introduce some guidance laws for endurance, mission and coping with strong headwinds and autonomous landing.

A Study on NDT Techniques for Evaluation of Corrosion in Multi-layered Conductive Structures of Urban Railroad Car of the paper (도시철도차량의 다층 구조물 부식 측정을 위한 비파괴 기법 연구)

  • Lee, Chan-Woo;Chung, Jung-Duk;Song, Sung-Jin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2691-2696
    • /
    • 2011
  • THE CARBODY AND BOGIE FRAME OF AN URBAN RAILWAY VEHICLE CONSIST OF MULTI-LAYERED WELDING STRUCTURE. IN KOREA ENDURANCE LIMIT OF AN URBAN RAILWAY VEHICLE IS STSTED IN THE RULE OF MANAGING URBAN RAILWAY VEHICLE UNDER THE LAW OF URBAN RAILWAY. IN KOREA AN URBAN RAILWAY VEHICLE IS DESIGNED AND MADE TO KEEP ITS QUALITY OVER 25 YEARS. WHEN THE RAILWAY VEHICLE BECOMES 25 YEARS OLD, CORROSION OF CARBODY AND UNDER FRAME OF A RAILWAY VEHICLE IS EVALUATED ACCORDING TO THE NON-DESTRUCTIVE TESTING. IT CAN BE USED AS LONG AS 40 YEARS. IT IS STATED IN THE ARTICLE 4 'THE METHOD AND STANDARDS OF PRECISE DIAGNOSIS' UNDER THE RULE OF MANAGING RAILWAY VEHICLE IN KOREA. SO, IN THIS STUDY, WE HAVE INVESTIGATED PERFORMANCE OF PULSED EDDY CURRENT TESTING METHOD BY MEASURING THICKNESS VARIATION OF FABRICATE OF CARBODY AND UNDER FRAME FOR URBAN RAILROAD CAR. AND THEM, THE PROCESS OF EVALUATING REMAINING LIFE ACCORDING TO TESTING OF CORROSION AMOUNT IS INTRODUCED.

  • PDF

A STUDY ON THE LOW REYNOLDS NUMBER AIRFOILS FOR THE DESIGN OF THREE DIMENSIONAL WING (3차원 날개 설계를 위한 저레이놀즈수 에어포일에 대한 연구)

  • Jung, K.J.;Lee, J.;Kwon, J.H.;Kang, I.M.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.90-96
    • /
    • 2009
  • In this study, a generic airfoil designed by the inverse method was evaluated with several candidate airfoils as a first step. Each airfoil was compared with respect to aerodynamic performance to meet the requirement of HALE(high altitude long endurance) aircraft. The second step was to optimize the candidate airfoil using the couple of optimization formulations to down select an optimum airfoil. For the analysis of low Reynolds number 2D flow, Drela's MSES was used. After comparing the aerodynamic results, the best airfoil was chosen to construct the baseline 3D wing. The Navier-Stokes code was used to evaluate the overall aerodynamic performance of designed wing with other wings. The results show that the designed wing has the best performance compared with other wings.

  • PDF

Numerical Study on Heat Transfer of Air-cooling PEMFC in HALE UAV (고고도 무인기 내부의 공랭식 PEMFC 열전달 전산 해석 연구)

  • SONG, MYEONGHO;KIM, KYOUNGYOUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.150-155
    • /
    • 2017
  • Proper cooling of PEM fuel cell stack is essential for the high-performance operation of fuel cell system. Insufficient cooling of the stack can cause significant damage to components due to overheating and also can decrease cell performance by dehydration of the polymer electrolyte. In the present study, we performed a computational analysis to assess the condition of the cooling system to secure the proper temperature in fuel cell stack system for high altitude long endurance (HALE) unmanned aerial vehicle (UAV).

Experimental Study on Slenderness Effects in Concrete-Filled Glass Fiber Reinforced Polymer Composite Columns (콘크리트 충전 유리섬유 복합소재 기둥의 세장비 특성에 관한 실험적 연구)

  • Choi, Sok-Hwan;Lee, Sung-Woo;Sohn, Ki-Hoon;Lee, Myung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.585-590
    • /
    • 2001
  • The structural characteristics of concrete-filled glass fiber reinforced polymer tubes were studied. The concept of concrete-filled composite columns was introduced to overcome the corrosion problems associated with steel and concrete piles under severe environments. Other benefits of composite columns include low maintenance cost, high earthquake resistance, and long expected endurance period. Several experiments were conducted; 1) compression test for short-length composite columns, 2) uniaxial compression tests on a total of 7 columns with various slenderness ratios. Short-length columns give higher strength and ductility revealing high confinement action in concrete. Failure strengths, failure patterns, confinement effects, and stress-strains relations were analyzed for slender columns. Current study will show the feasibility of concrete-filled glass fiber reinforced polymer composite columns in corrosive environments, and will provide an experimental database for columns that are externally reinforced by multidirectional fibers.

  • PDF

A Study on Unmaned Underwater Vehicle Operational Performance Analysis for Mine Search Operation (무인잠수정 기뢰 탐색 효과도 분석)

  • Hwang, A-Rom;Kim, Moon-Hwan;Lee, Sim-Yong;Yoon, Jae-Moon;Kim, Chan-Ki
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.781-787
    • /
    • 2011
  • Mine countermeasure missions(MCMs) may induce the loss of human and ship because of the covert of mine. In recent years, unmanned underwater vehicles(UUVs) have emerged as viable technical solution for conductimg underwater search, surveillance, and clearance operations in support of mine countermeasure missions because of her autonomy and long time endurance capability. This paper introduces a technical approach to mine countermeasure mission effectiveness analysis and presents some simulation-based analysis results for engineering of the UUV system definition which could be support analysis of alternatives for system definition and design.

Reliability Assessment on the Indoor Vacuum Circuit Breaker Used in Distribution System (배전급 옥내용 진공차단기의 신뢰성평가)

  • Kim, Min-Kyu;Kim, Maeng-Hyun;Shin, Young-June
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.160-163
    • /
    • 2003
  • This paper represent a test method for the reliability assessment on the indoor vacuum circuit breakers used in the distribution system by an accelerated life test. In order to guarantee the lifetime in service of the vacuum circuit breaker, additional test methods are suggested. Multiple closing-opening operation test under no load condition as a mechanical endurance test and a check of the quality in the vacuum interrupter are adopted to assure the long-term reliability of the vacuum circuit breaker.

  • PDF

Basic Study of Degradation Test for Magnetic Contactors and Reliability Centered Maintenance

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.441-444
    • /
    • 2007
  • The mechanical endurance is the critical characteristic of Magnetic contactors (MCs), which are widely used in such industrial equipments as elevators, cranes, and factory control rooms in order to close and open the control circuit. Testing time, however, is so long in most cases that some method of reducing the testing period is required. Therefore, the degradation test by the detected vibration of MCs is developed to reduce the testing time in this work. The degradation test data are analyzed and the prediction model is provided. Also, the possibility of this technology for Reliability Centered Maintenance (RCM) will be shown. This will reduce the period of the product development and raise the reliability of the equipment in power distribution.

A study on the fire risk analysis on the railway tunnel and subway area (철도터널 및 지하구간에서의 화재사고 위험성 분석 연구)

  • Wang Jong Bae;Hong Seon Ho;Kim Sang Ahm;Park Ok Jeong
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.271-276
    • /
    • 2003
  • In this paper, various hazard factors are reviewed on the train fire accident in railway tunnel and subway. In case studies of systematic risk evaluation on the tunnel fire accident, we have learned the critical fire safety points for accident prevention and damage reduction such as fire-endurance of infrastructure, mortality of heat & toxic smoke, emergency situation control and management of escape requirements etc.. These hazard analysis study will contribute for improving the railway fire-safety and establishing the long-tenn safety management plan.

  • PDF

The Present State of UAV Propulsion and Forecast of Next Generation UAV Propulsion (UAV 추진기관의 현황 및 차세대 UAV 추진기관의 개발 전망)

  • Lee, Dong-Hun;Paeng, Ki-Suk;Kim, Yu-Il;Par, Poo-Min;Choi, Seong-Man;Huh, Hwan-Il
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.557-560
    • /
    • 2009
  • The characteristics and present state of UAV engine which is operating currently were studied and advantages/disadvantages of UAV engines were also analyzed. Forecast of next generation UAV engine development trend was presented and the performance demand of gas turbine engine for UAV were suggested.

  • PDF