• Title/Summary/Keyword: Long Span

Search Result 1,123, Processing Time 0.022 seconds

Behavior Character Analysis of Super Long Suspension Bridge using GNSS (GNSS를 활용한 초장대 현수교의 거동 특성 분석)

  • Park, Je-Sung;Hong, Seunghwan;Kim, Mi-Kyeong;Kim, Tai-Hoon;Sohn, Hong-Gyoo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.5_2
    • /
    • pp.831-840
    • /
    • 2019
  • Recently, the span length of long-span bridges is getting longer. As a result, it has been suggested that a new concept called 'super long-span bridge'. In case of super long span bridges, the structure is being complicated and the importance of structural stability is being emphasized. However, until recently, the most commonly used sensors (dual axis clinometer, anemometer, strain gauge, etc.) have got limit about the bridge monitoring. Consequently, we researched the application of a Global Navigation Satellite System (GNSS) to improve the limit of the existing sensors. In this study, the dual axis clinometer, the anemometer and the strain gauge together with the GNSS were used to analyze the behavior of a super-long suspension bridge. Also, we propose the detailed method of bridge monitoring using the GNSS. This study consisted of three steps. First step calculated the absolute coordinates of the towers and the longitudinal axis direction of the study bridge using the GNSS. In second step, through the analysis of the long-term behavior in shortly after construction, we calculated the permanent displacement and evaluated the stability of main towers. Third step analyzed the behavior of bridge by the wind direction and was numerically indicated. Consequently, the bridge measurement using the GNSS appeared that the acquired data is able to easy processing according to the analysis purpose. If we will use together the existing measurement sensors with the GNSS on the maintenance of the super long-span bridge, we figure each error of measurement data and improve the monitoring system through calibration. As a result, we acquire the accurate displacement of bridge and figure the behavior of bridge. Consequently, we identified that it is able to construct the effective monitoring system.

Large eddy simulation of wind loads on a long-span spatial lattice roof

  • Li, Chao;Li, Q.S.;Huang, S.H.;Fu, J.Y.;Xiao, Y.Q.
    • Wind and Structures
    • /
    • v.13 no.1
    • /
    • pp.57-82
    • /
    • 2010
  • The 486m-long roof of Shenzhen Citizens Centre is one of the world's longest spatial lattice roof structures. A comprehensive numerical study of wind effects on the long-span structure is presented in this paper. The discretizing and synthesizing of random flow generation technique (DSRFG) recently proposed by two of the authors (Huang and Li 2008) was adopted to produce a spatially correlated turbulent inflow field for the simulation study. The distributions and characteristics of wind loads on the roof were numerically evaluated by Computational Fluid Dynamics (CFD) methods, in which Large Eddy Simulation (LES) and Reynolds Averaged Navier-Stokes Equations (RANS) Model were employed. The main objective of this study is to explore a useful approach for estimations of wind effects on complex curved roof by CFD techniques. In parallel with the numerical investigation, simultaneous pressure measurements on the entire roof were made in a boundary layer wind tunnel to determine mean, fluctuating and peak pressure coefficient distributions, and spectra, spatial correlation coefficients and probability characteristics of pressure fluctuations. Numerical results were then compared with these experimentally determined data for validating the numerical methods. The comparative study demonstrated that the LES integrated with the DSRFG technique could provide satisfactory prediction of wind effects on the long-span roof with complex shape, especially on separation zones along leading eaves where the worst negative wind-induced pressures commonly occur. The recommended LES and inflow turbulence generation technique as well as associated numerical treatments are useful for structural engineers to assess wind effects on a long-span roof at its design stage.

Structural Health Monitoring System of Long-Span Bridges in Korea

  • Chang, Sung-Pil
    • Corrosion Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.39-46
    • /
    • 2004
  • Development and application of structural health monitoring system in Korea have become active since the early 1990's. In earlier applications, health monitoring systems were installed in several existing bridges in order to collect initial field data by full scale load capacity test for design verification and subsequently monitor long-term performance and durability of the bridge as part of an inspection and maintenance program. Recently, modem and integrated monitoring systems have been introduced in most of the newly constructed long-span bridges since the design stage. This paper outlines the progresses and applications of monitoring systems in Korea for both existing and newly constructed bridges and describes their aims and characteristics.

Effects of Partially Earth Anchored Cable System on Safety Improvement for a Long-span Cable-stayed Bridge under Seismic and Wind Load (장경간 사장교에 적용된 일부타정식 케이블 시스템의 지진하중과 풍하중 안전성 향상 효과 분석)

  • Won, Jeong-Hun;Lee, Hyung Do
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.97-103
    • /
    • 2016
  • This study investigates effects of partially earth anchored cable system on the structural safety for a long-span cable-stayed bridge under dynamic loads such as seismic and wind load. For a three span cable-stayed bridge with a main span length of 810 m, two models are analyzed and compared; one is a bridge model with a self anchored cable system, the other is a bridge model with a partially earth anchored cable system. By performing multi-mode spectrum analysis for a prescribed seismic load and multi-mode buffeting analysis for a fluctuating wind component, the structural response of two models are compared. From results, the partially earth anchored cable system reduce the maximum pylon moment by 66% since earth anchored cables affect the natural frequencies of girder vertical modes and pylon longitudinal modes. In addition, the girder axial forces are decreased, specially the decrement of the axial force is large in seismic load, while girder moment is slightly increased. Thus, the partially earth anchored cable system is effective system not only on reduction of girder axial forces but also improvement of structural safety of a cable-stayed bridge under dynamic loads such as seismic and wind loads.

The Development of Structural System of Long-span Greenhouse Using the Pre-Engineering Building System (선설계기법을 이용한 장경간 유리온실 구조시스템 개발)

  • Oh, Myoung-Ho;Kim, Yong-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Rural facilities need to be changed to be industrialized and long span structures due to accelerating aging of the rural population. In this study, the optimized structure was developed by applying Pre-Engineered Building System using the tapered member to make that the Korea standard green house has a long span. When considering design load, reasonable values were adapted by reviewing existing design codes. As a result, applying pre-engineered building system was efficient in structural system that has span longer than 16 m. And it was concluded that the increase with the longitudinal span from 4 m to 12 m was more efficient in aspect of steel amount.

A Study on Seismic Capacity Assessment of Long-Span Suspension Bridges by Construction Methods Considering Earthquake Characteristics (지진특성을 고려한 장경간 현수교량의 시공방안별 내진성능 평가에 관한 연구)

  • Han, Sung Ho;Jang, Sun Jae;Lim, Nam Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.2A
    • /
    • pp.93-102
    • /
    • 2010
  • The numerical analysis and safety assessment by construction stages were considered the essential examination particular in order to solving the unstability of long-span bridges in the middle a construction. When estimating structural response characteristics by the construction stage analysis of long-span bridges, the influence of the near-field ground motion (NFGM) would be evaluated as a critical factor for the seismic design because it indicates clearly different aspects from the existing input earthquake motion data. Therefore, this study re-examined the response aspect of long-span bridges considering NFGM characteristics based on the response spectrum result, and advanced the presented numerical analysis program by the related research for conducting the construction stage analysis and reliability assessment of long-span bridges efficiently. The excellency of various construction schemes was assessed using the time history analysis result of critical member considering NFGM characteristics. For evaluating quantitative safety level, the reliability analysis was conducted considering the influence of external uncertainties included in random variables, and presented the safety index and failure probability of the critical construction stage by NFGM characteristics. In addition, the reliability result was examined the influence of internal uncertainties using monte carlo simulation (MCS), and assessed the distribution aspect of the essential analysis result. It is expected that this study will provide the basic information for the construction safety improvement when performing seismic design of long-span bridges considering NFGM characteristics.

Flutter stability of a long-span suspension bridge during erection

  • Han, Yan;Liu, Shuqian;Cai, C.S.;Li, Chunguang
    • Wind and Structures
    • /
    • v.21 no.1
    • /
    • pp.41-61
    • /
    • 2015
  • The flutter stability of long-span suspension bridges during erection can be more problematic and more susceptible to be influenced by many factors than in the final state. As described in this paper, numerical flutter stability analyses were performed for the construction process of Zhongdu Bridge over Yangtze River using the commercial FE package ANSYS. The effect of the initial wind attack angle, the sequence of deck erection, the stiffness reduction of stiffening girders, the structural damping, and the cross cables are discussed in detail. It was found that the non-symmetrical sequence of deck erection was confirmed to be aerodynamically favourable for the deck erection of long-span suspension bridges and the best erection sequence should be investigated in the design phase. While the initial wind attack angle of $-3^{\circ}$ is advantageous for the aerodynamic stability, $+3^{\circ}$ is disadvantageous compared with the initial wind attack angle of $0^{\circ}$ during the deck erection. The stiffness reduction of the stiffening girders has a slight effect on the flutter wind speed of the suspension bridge during erection, but structural damping has a great impact on it, especially for the early erection stages.

Flutter suppression of long-span suspension bridge with truss girder

  • Wang, Kai;Liao, Haili;Li, Mingshui
    • Wind and Structures
    • /
    • v.23 no.5
    • /
    • pp.405-420
    • /
    • 2016
  • Section model wind tunnel test is currently the main technique to investigate the flutter performance of long-span bridges. Further study about applying the wind tunnel test results to the aerodynamic optimization is still needed. Systematical parameters and test principle of the bridge section model are determined by using three long-span steel truss suspension bridges. The flutter critical wind at different attack angles is obtained through section model flutter test. Under the most unfavorable working condition, tests to investigate the effects that upper central stabilized plate, lower central stabilized plate and horizontal stabilized plate have on the flutter performance of the main beam were conducted. According to the test results, the optimal aerodynamic measure was chosen to meet the requirements of the bridge wind resistance in consideration of safety, economy and aesthetics. At last the credibility of the results is confirmed by full bridge aerodynamic elastic model test. That the flutter reduced wind speed of long-span steel truss suspension bridges stays approximately between 4 to 5 is concluded as a reference for the investigation of the flutter performance of future similar steel truss girder suspension bridges.

The influence of vehicles on the flutter stability of a long-span suspension bridge

  • Han, Yan;Liu, Shuqian;Cai, C.S.;Zhang, Jianren;Chen, Suren;He, Xuhui
    • Wind and Structures
    • /
    • v.20 no.2
    • /
    • pp.275-292
    • /
    • 2015
  • The presence of traffic on a slender long-span bridge deck will modify the cross-section profile of the bridge, which may influence the flutter derivatives and in turn, the critical flutter wind velocity of the bridge. Studies on the influence of vehicles on the flutter derivatives and the critical flutter wind velocity of bridges are rather rare as compared to the investigations on the coupled buffeting vibration of the wind-vehicle-bridge system. A typical streamlined cross-section for long-span bridges is adopted for both experimental and analytical studies. The scaled bridge section model with vehicle models distributed on the bridge deck considering different traffic flow scenarios has been tested in the wind tunnel. The flutter derivatives of the modified bridge cross section have been identified using forced vibration method and the results suggest that the influence of vehicles on the flutter derivatives of the typical streamlined cross-section cannot be ignored. Based on the identified flutter derivatives, the influence of vehicles on the flutter stability of the bridge is investigated. The results show that the effect of vehicles on the flutter wind velocity is obvious.

POD-based representation of the alongwind Equivalent Static Force for long-span bridges

  • Fiore, Alessandra;Monaco, Pietro
    • Wind and Structures
    • /
    • v.12 no.3
    • /
    • pp.239-257
    • /
    • 2009
  • This paper develops and discusses a method by which it is possible to evaluate the Equivalent Static Force (ESF) of wind in the case of long-span bridges. Attention is focused on the alongwind direction. The study herein carried out deals with the classical problems of determining the maximum effects due to the alongwind action and the corresponding ESFs. The mean value of the maximum alongwind displacement of the deck is firstly obtained both by the spectral analysis and the Gust Response Factor (GRF) technique. Successively, in order to derive the other wind-induced effects acting on the deck, the Gust Effect Factor (GEF) technique is extended to long-span bridges. By adopting the GRF technique, it is possible to define the ESF that applied on the structure produces the maximum alongwind displacement. Nevertheless the application of the ESF so obtained does not furnish the correct maximum values of other wind-induced effects acting on the deck such as bending moments or shears. Based on this observation, a new technique is proposed which allows to define an ESF able to simultaneously reproduce the maximum alongwind effects of the bridge deck. The proposed technique is based on the GEF and the POD techniques and represents a valid instrument of research for the understanding of the wind excitation mechanism.