• Title/Summary/Keyword: Long Distance

Search Result 2,174, Processing Time 0.027 seconds

Modification of the Cox-Maze Procedure for Atrial Fibrillation with Large Left Atrium ; Development of Surgical Technique to Increase the Left Atrial Contractility (좌심방 확장을 동반한 심방세동에 대한 Cox-Maze 수술법의 변형 -수술후 좌심방 수축력의 증진을 위한 수술법의 개량-)

  • 강창현;김기봉;손대원
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.249-254
    • /
    • 1999
  • Background: Recovery of the left atrial contractile function after the Cox-Maze procedure is related to the size of the left atrium. We have postulated that if too wide area of the atrium were isolated electrically, then the atrial contractile function would be impaired postoperatively. We have modified the Cox-Maze procedure to dissect each pair of the pulmonary veins separately instead of the conventional pulmonary vein encircling incision, and compared the atrial contractile function after each procedure. Material and Method: From February 1995 to October 1997, 55 cases of the Cox-Maze procedure were performed in mitral valvular heart disease. We excluded the cases that did not covert to sinus rhythm. The patient groups were divided according to the interpulmonary vein distance(IPVD) and the procedure performed. Group I was IPVD under 6.5 cm(n=30), group II was IPVD over 6.5cm and the conventional Cox-Maze III procedure was performed(n=16), and group III was IPVD over 6.5cm and the modified Cox-Maze procedure was performed(n=9). Result: Atrial contractile function was evaluated by the echocardiography follow-up between 6 months to 12 months. The right atrial contractile function recovered gradually, the recovery rate after long-term follow-up was 90% in group I, 81% in group II, and 100% in group III(p>0/05). In the left atrium the recovery rate was 63% in group I, 31% in group II(p=0.03), and 66% in group III(p>0.05). Conclusion: The modified Cox-Maze procedure may have beneficial effects on the recovery of the left atrial contractile function, however, there are no statistically significant values. Therefore, further evaluation of this procedure is necessary.

  • PDF

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

The Status of Studies on Historical Wall Relics in the Jeju Area and the Strategic Direction for Their Preservation and Maintenance (제주도 지역 성곽 유산 연구 현황과 보존·정비 방향)

  • Byun, Seong-hun
    • Korean Journal of Heritage: History & Science
    • /
    • v.52 no.1
    • /
    • pp.64-81
    • /
    • 2019
  • Jeju Island is located at a strategic position, making it an important waypoint on the sea routes of East Asia. As a result, the island suffered many foreign invasions throughout history. Especially, it is widely known that Japanese pirates frequently invaded the island as the island was located on their way as they were sailing to China. Therefore, they built various defensive structures across the island. Fortresses, where a small number of defenders may fend off an enemy, were built in multiple places on the island. This was a strategy for the island to defend itself, as it was almost impossible to get prompt support in an emergency from the mainland due to the long distance. Fortresses, or walled cities, were the center of politics, culture, and economy of many areas. Therefore, they are a valuable resource to study the history and geographical characteristics of a place. For this reason, studies on fortresses started quite early on. However, studies on such relics in Jeju Island began very late. The research on fortresses was launched during the Japanese occupation for most mainland areas. However, studies on the relics on Jeju Island began as late as the 1970s. This was because scholars did not understand the importance of the city walls and fortresses on Jeju Island, and there were no researchers who specialized in city walls or fortresses on the island, as well. As archeological research on Jeju Island began to gain momentum, the studies on city walls and fortresses saw progress; however, these studies are still of an elementary level. In this study, the author summarized the status of studies on the city walls and fortress relics in Jeju Island and their preservation/maintenance status by era. According to the findings of this study, there were two Corean-era city wall/fortress relics and thirteen from the Chosun era., The researcher analyzed and presented the status of studies and the current condition of the relics. The status of attached structures was also documented.Furthermore, a short review of the maintenance work performed so far was provided. Also, the researcher mentioned the problems that accompanied the maintenance process of these relics, along with suggestions for improvement that could be referred to in future restoration/maintenance projects.

A Study on the Place-Cognition Characteristics of Historic Cultural Streets in Deoksugung Doldam-gil (덕수궁 돌담길의 역사문화가로 장소 인식 특성에 관한 연구)

  • Yang, Yoo-sun;Son, Yong-hoon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.3
    • /
    • pp.60-70
    • /
    • 2019
  • Today, Deoksugung Doldam-gil, which is a well-known area in Seoul, has become a mixed place as many places reaching a critical age have been converted into parks. However, the previous research on the Deoksugung Doldam-gil was deficient in that the user, an essential variable, was not considered when assessing the place. Based on that, this study aims to analyze and interpret the perception of the places in Deoksugung Doldam-gil and to analyze factors to further enrich the place to visitors. According to the research, the representative idea of Deoksugung Doldam-gil is "the distance you want to go" and that has influencing factors, such as vehicle restrictions and the improvement of the walking environment. The analysis of classifying the variables that make up the perception of the place, physical environments, activities and meanings showed high awareness in, "streets of green (3.95)" and "stone walls of curves (3.88)." In the category of activities, "walking activities in the inner city (4.01)" and "love and romance (3.57)" were high. These results seem to reflect the spatial characteristics of the streets and the familiar image of the place were important. Five factors were extracted from the factor analysis to provide a more detailed understanding of the place perception, the correlation between each factor, and the place atmosphere of Deoksugung Doldam-gil. These factors confirmed a high correlation between 'green landscape' and 'historicity.' This can be attributed to the fact that the analysis reflects vital space, visual experience, and free walking conditions to be important, and these variables are present in urban parks. It also indicates the long-accumulated image and behavior near the site of Deoksugung Palace, including the historical and cultural heritage. It was confirmed that the factors related to the cognitive perception of Deoksugung Doldam-gil and the formation of the atmosphere of the place were strongly recognized. It found that there was a need to reflect the value and importance of 'green' in the future as culture or in the use of preservation and management related to heritage. This study presented a direction to be noted from the perspective of a user's place awareness, but considered only a fraction of the variables that affect the multidimensional sense of place and location recognition, and thus must be supplemented in the future.

Analysis of PM2.5 Concentration and Contribution Characteristics in South Korea according to Seasonal Weather Patternsin East Asia: Focusing on the Intensive Measurement Periodsin 2015 (동아시아 지역의 계절별 기상패턴에 따른 우리나라 PM2.5 농도 및 기여도 특성 분석: 2015년 집중측정 기간을 중심으로)

  • Nam, Ki-Pyo;Lee, Dae-Gyun;Jang, Lim-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.3
    • /
    • pp.183-200
    • /
    • 2019
  • In this study, the characteristics of seasonal $PM_{2.5}$ behavior in South Korea and other Northeast Asian regions were analyzed by using the $PM_{2.5}$ ground measurement data, weather data, WRF and CMAQ models. Analysis of seasonal $PM_{2.5}$ behavior in Northeast Asia showed that $PM_{2.5}$ concentration at 6 IMS sites in South Korea was increased by long-distance transport and atmospheric congestion, or decreased by clean air inflow due to seasonal weather characteristics. As a result of analysis by applying BFM to air quality model, the contribution from foreign countries dominantly influenced the $PM_{2.5}$ concentrations of Baengnyeongdo due to the low self-emission and geographical location. In the case of urban areas with high self-emissions such as Seoul and Ulsan, the $PM_{2.5}$ contribution from overseas was relatively low compared to other regions, but the standard deviation of the season was relatively high. This study is expected to improve the understanding of the air pollutant phenomenon by analyzing the characteristics of $PM_{2.5}$ behavior in Northeast Asia according to the seasonal weather condition change. At the same time, this study can be used to establish the air quality policy in the future, knowing that the contribution of $PM_{2.5}$ concentration to the domestic and overseas can be different depending on the regional emission characteristics.

Tracing the Drift Ice Using the Particle Tracking Method in the Arctic Ocean (북극해에서 입자추적 방법을 이용한 유빙 추적 연구)

  • Park, GwangSeob;Kim, Hyun-Cheol;Lee, Taehee;Son, Young Baek
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_2
    • /
    • pp.1299-1310
    • /
    • 2018
  • In this study, we analyzed distribution and movement trends using in-situ observations and particle tracking methods to understand the movement of the drift ice in the Arctic Ocean. The in-situ movement data of the drift ice in the Arctic Ocean used ITP (Ice-Tethered Profiler) provided by NOAA (National Oceanic and Atmospheric Administration) from 2009 to 2018, which was analyzed with the location and speed for each year. Particle tracking simulates the movement of the drift ice using daily current and wind data provided by HYCOM (Hybrid Coordinate Ocean Model) and ECMWF (European Centre for Medium-Range Weather Forecasts, 2009-2017). In order to simulate the movement of the drift ice throughout the Arctic Ocean, ITP data, a field observation data, were used as input to calculate the relationship between the current and wind and follow up the Lagrangian particle tracking. Particle tracking simulations were conducted with two experiments taking into account the effects of current and the combined effects of current and wind, most of which were reproduced in the same way as in-situ observations, given the effects of currents and winds. The movement of the drift ice in the Arctic Ocean was reproduced using a wind-imposed equation, which analyzed the movement of the drift ice in a particular year. In 2010, the Arctic Ocean Index (AOI) was a negative year, with particles clearly moving along the Beaufort Gyre, resulting in relatively large movements in Beaufort Sea. On the other hand, in 2017 AOI was a positive year, with most particles not affected by Gyre, resulting in relatively low speed and distance. Around the pole, the speed of the drift ice is lower in 2017 than 2010. From seasonal characteristics in 2010 and 2017, the movement of the drift ice increase in winter 2010 (0.22 m/s) and decrease to spring 2010 (0.16 m/s). In the case of 2017, the movement is increased in summer (0.22 m/s) and decreased to spring time (0.13 m/s). As a result, the particle tracking method will be appropriate to understand long-term drift ice movement trends by linking them with satellite data in place of limited field observations.

Study on Standardization of the Environmental Impact Evaluation Method of Extremely Low Frequency Magnetic Fields near High Voltage Overhead Transmission Lines (고압 가공송전선로의 극저주파자기장 환경영향평가 방법 표준화에 관한 연구)

  • Park, Sung-Ae;Jung, Joonsig;Choi, Taebong;Jeong, Minjoo;Kim, Bu-Kyung;Lee, Jongchun
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.658-673
    • /
    • 2018
  • Social conflicts with extremely low frequency magnetic field(ELF-MF) exposures are expected to exacerbate due to continued increase in electric power demand and construction of high voltage transmission lines(HVTL). However, in current environmental impact assessment(EIA) act, specific guidelines have not been included concretely about EIA of ELF-MF. Therefore, this study conducted a standardization study on EIA method through case analysis, field measurement, and expert consultation of the EIA for the ELF-MF near HVTL which is the main cause of exposures. The status of the EIA of the ELF-MF and the problem to be improved are derived and the EIA method which can solve it is suggested. The main contents of the study is that the physical characteristics of the ELF-MF affected by distance and powerload should be considered at all stages of EIA(survey of the current situation - Prediction of the impacts - preparation of mitigation plan ? post EIA planning). Based on this study, we also suggested the 'Measurement method for extremely low frequency magnetic field on transmission line' and 'Table for extremely low frequency magnetic field measurement record on transmission line'. The results of this study can be applied to the EIA that minimizes the damage and conflict to the construction of transmission line and derives rational measures at the present time when the human hazard to long term exposure of the ELF-MF is unclear.

Research on an aristocratic officer's travels in the mid Chosun Korea by analysing Yu Hee-chun's diary (일기(日記)를 이용한 조선중기 양반관료의 여행 연구)

  • Jung, Chi-Young
    • Journal of Korean Historical Folklife
    • /
    • no.26
    • /
    • pp.71-106
    • /
    • 2008
  • The objective of this research is to reconstruct an aristocratic officer's travels by analysing Yu, hee-chun's diary, Miamilgi. Yu had kept his diary for eighty three months, from October 1567 to May 1577, and there were twenty six times of travel logs which are analysed in this research. As a result of the analysis, his travels can be divided into official travels and private travels. Sixteen times of official travels were comprised of inspection tours for parishes as a superintendent of Jeonra province, trips to supervise maintenance works of royal tombs and to worship the tombs, to carry out the sanjae (rituals in the mountains) as a second minister of the ministry of rites. It was difficult for him to have private travels as he continually served as a royal officer. He had got only 10 times of private travels during the eighty three months for maintaining the ancestor's tomb and worshiping the ancestors, for recuperating himself and his wife, and for constructing his new house. All of these travels were long-distance ones. In terms of his travel routes, he frequently used royal main trunks, e.g. 'Haenamro' (from Seoul to Damyang), which were maintained by the royal government. The main reason of his frequent using of trunk lines was that convenience facilities such as the royal post stations (Yeok) and royal inns (Won) were equipped well in these roads so it was easy to get horse change services and lodging and boarding. The fact that main trunks were chiefly straight lines and the shortest way was rather secondary reason. On the other hand, when he was a superintendent of Junra province, he had four times of round inspection on all parishes of Junra province, following the tour routs covering all over the province. As he was incumbent royal officer, he started his travel by getting a permission from the king. Simultaneously, he made ready some travel items. Among the items, horse was most important one for the journey. After finishing all the preparing processes before the departure, he had special farewell ceremony for the King, Sookbae, and had a small party with his friends called Jeonbeul. Main transportation means for his travel was horse, and many kinds of horses such as royal government's horse, Yeokma, local government's horse, Swema, as well as his private one were used. Additionally, he used a palanquin while he was doing inspection trip as a superintendent of Junra province. Yu was incumbent officer so he mostly lodged in local government guest houses. If he could not find out any local guest house, he was lodged in royal inn, and in his relatives houses or irregularly in buddhist temples. Most meals were supplied by local royal governments. The activities in his journeys were varied on his travel objectives. In his private journey, it was the main activities that maintaining ancestor's tombs and having a memorial service. During the trip, he visited his relatives. His official trips, on the other hand, had a regularity. Main activities were dealing with public works, and visiting Hyanggyo (country public school). However in the midway, he visited his relatives and had a journey to scenic places.

A Study on Termite Monitoring Method Using Magnetic Sensors and IoT(Internet of Things) (자력센서와 IoT(사물인터넷)를 활용한 흰개미 모니터링 방법 연구)

  • Go, Hyeongsun;Choe, Byunghak
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.1
    • /
    • pp.206-219
    • /
    • 2021
  • The warming of the climate is increasing the damage caused by termites to wooden buildings, cultural properties and houses. A group removal system can be installed around the building to detect and remove termite damage; however, if the site is not visited regularly, every one to two months, you cannot observe whether termites have spread within, and it is difficult to take prompt effective action. In addition, since the system is installed and operated in an exposed state for a long period of time, it may be ineffective or damaged, resulting in a loss of function. Furthermore if the system is installed near a cultural site, it may affect the aesthetic environment of the site. In this study, we created a detection system that uses wood, cellulose, magnets, and magnetic sensors to determine whether termites have entered the area. The data was then transferred to a low power LoRa Network which displayed the results without the necessity of visiting the site. The wood was made in the shape of a pile, and holes were made from the top to the bottom to make it easier for termites to enter and produce a cellulose sample. The cellulose sample was made in a cylindrical shape with a magnet wrapped in cellulose and inserted into the top of a hole in the wood. Then, the upper part of the wood pile was covered with a stopper to prevent foreign matter from entering. It also served to block external factors such as light and rainfall, and to create an environment where termites could add cellulose samples. When the cellulose was added by the termites, a space was created around the magnet, causing the magnet to either fall or tilt. The magnetic sensor inside the stopper was fixed on the top of the cellulose sample and measured the change in the distance between the magnet and the sensor according to the movement of the magnet. In outdoor experiments, 11 cellulose samples were inserted into the wood detection system and the termite inflow was confirmed through the movement of the magnet without visiting the site within 5 to 17 days. When making further improvements to the function and operation of the system it in the future, it is possible to confirm that termites have invaded without visiting the site. Then it is also possible to reduce damage and fruiting due to product exposure, and which would improve the condition and appearance of cultural properties.