• 제목/요약/키워드: Long Bar

검색결과 273건 처리시간 0.025초

유전 알고리듬을 이용한 소형 고속스핀들 시스템의 바-피더 지지부의 위치 최적선정 (Optimum Bar-feeder Support Positions of a Miniature High Speed Spindle System by Genetic Algorithm)

  • 이재훈;김무수;박성훈;강재근;이시복
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.99-107
    • /
    • 2009
  • Since a long work piece influences the natural frequency of the entire system with a miniature high speed spindle, a bar-feeder is used for a long work piece to improve the vibration characteristics of a spindle system. Therefore, it is very important to design optimally support positions between a bar-feeder and a long work piece for a miniature high speed spindle system. The goal of the current paper is to present an optimization method for the design of support positions between a bar-feeder and a long work piece. This optimization method is effectively composed of the method of design of experiment (DOE), the artificial neural network (ANN) and the genetic algorithm (GA). First, finite element models which include a high speed spindle, a long work piece and the support conditions of a bar-feeder were generated from the orthogonal array of the DOE method, and then the results of natural vibration analysis using FEM were provided for the learning inputs of the neural network. Finally, the design of bar-feeder support positions was optimized by the genetic algorithm method using the neural network approximations.

송천 하구 사주의 지형 특성과 변화 과정 (Geomorphological Properties and Changes on River-Mouth Bar at Song-cheon River)

  • 이광률
    • 대한지리학회지
    • /
    • 제46권6호
    • /
    • pp.693-706
    • /
    • 2011
  • 본 연구는 경상북도 영덕군 동해안의 송천 하구 사주를 대상으로, 지형의 형태적 특성과 형성 시기를 파악하고, 장기적 및 단기적인 하구 사주의 변화 과정과 원인을 분석하였다. 사주의 해안선 부근 모래는 남에서 북으로 갈수록 입도가 점차 감소하여, 파랑과 연안류가 대체로 북쪽으로 이동하는 경향이 강한 것으로 보인다. 하구 사주와 인근 해안사구 모래의 절대연대는 약 100년 이내로서 지형의 변화가 매우 심하였다. 하구 사주 내의 입수구는 1971년부터 1995년까지 사주의 남쪽에 위치하였으나, 1995년부터 현재까지는 사주의 북쪽이나 중앙에 나타나고 있는데, 그 원인은 2000년 이후 바람과 해류의 북류 경향이 뚜렷해지면서 파랑과 연안류의 이동 방향이 변화된 결과로 판단된다. 단기적으로 볼 때, 주로 9월부터 3월 사이에 파랑과 바람의 작용으로 퇴적작용이 우세하여 사주의 고도가 상승하고 면적이 넓어지며 지형 기복이 단순해지고, 입수구의 위치와 사주의 형태 변화가 크게 나타났다.

계장화한 긴 바를 사용한 세라믹판의 충격 파괴 거동 (Impact Fracture Behavior of Ceramic Plates Instrumented Long Bar)

  • 신형섭;배영준;오상엽;김창욱;장순남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.561-566
    • /
    • 2001
  • A long bar impact test to alumina plates(AD 85 and AD 90) was carried out by using fabricated impact testing apparatus. The apparatus adopting a long bar of 2.1m in length made it possible to measure directly the applied impact force to the specimen during bar impact. The dimension of specimens was $33{\times}33mm$ and thickness was 3.4mm. Confinement of D2=18mm outer diameter and D1=10.5mm inner diameter was used to provide contact pressure to the specimen. Contact pressure of p=100 or 200MPa was applied to specimen before impact test. Damage caused in those cases were compared with the case of without contact pressure. The damage of specimen was different depending upon the pressure level of confinement. The existence of confinement had suppressed the development of radial cracks from the bottom of specimen and reduced the extent of damage as compared with cases without contact pressure(p=0MPa). Because the application of contact pressure to the specimen increased the apparent flexural stiffness of specimen during bar impact, it had produced the change of developed damage in the specimen; from the radial cracks to the local contact stress dominant damage. It would contribute to the improvement of the ballistic property in ceramic plates.

  • PDF

화학적 환경에 노출된 콘크리트 보강용 FRP 보강근의 장기 효과 (Long-Term Effect of Chemical Environments on FRP Reinforcing Bar for Concrete Reinforcement)

  • 박찬기;원종필;유정길
    • 콘크리트학회논문집
    • /
    • 제15권6호
    • /
    • pp.811-819
    • /
    • 2003
  • 철근의 부식은 철근콘크리트 구조물의 주요파괴 원인이다. 철근의 부식에 대한 문제점을 해결할 가능성이 있는 재료 중 FRP 보강근은 그 가능성이 높다. 그렇지만 FRP 보강근은 보강철근과 다른 파괴 매카니즘으로 의하여 현저하게 성능이 저하될 가능성을 가지고 있다. 이와 같은 환경에는 알칼리, 산, 염해 및 물과 수분 등이 있다. 따라서 본 연구에서는 FRP 보강근의 화학적 환경하에서의 내구성능을 평가하고자 하였으며 사용된 FRP 보강근은 2가지 종류의 CFRP 보강근 및 GFRP 보강근, 한가지 종류의 AFRP 보강근으로 알칼리용액, 산용액, 염해환경 및 중성용액에 노출시켰다. FRP 보강근의 역학적 특성 및 내구특성은 인장, 압축 및 전단시험을 통하여 평가하였으며 시험결과 FRP 보강근은 매우 혹독한 화학적 환경에서 우수한 내구성을 가지고 있음을 알 수 있었다.

CAD/CAM 시스템으로 제작한 Milled Bar를 이용한 하악 임플란트 피개의치 수복증례 (Rehabilitation using mandibular implant overdenture with CAD/CAM milled bar: A case report)

  • 반민희;양홍서;박상원;임현필;윤귀덕;신진호;박찬
    • 대한치과보철학회지
    • /
    • 제55권3호
    • /
    • pp.292-299
    • /
    • 2017
  • 무치악 환자에서 치아 상실 후 오랜 기간에 걸친 치조골 흡수는 의치의 사용을 어렵게 한다. 하악 무치악 환자에게 두 개 혹은 네 개의 임플란트를 식립하여 임플란트 피개의치를 이용하는 방식은 쉽게 접근할 수 있고, 의치의 유지, 지지와 안정을 크게 향상시킬 수 있는 방법이다. 임플란트 피개의치에 사용되는 어태치먼트 중에서 milled bar는 기성 bar보다 상부 구조물의 견고한 안정성과 충분한 유지력을 얻기 위해 사용할 수 있으며, 최근 CAD/CAM system의 발달과 함께 기공과정이 간소화되어 이용이 용이하게 되었다. 본 증례는 오랜 기간 상, 하악 총의치를 사용했던 환자에게 상악은 전통적인 방식으로 제작한 총의치와 하악에 네 개의 임플란트를 식립하여 CAD/CAM milled bar를 이용해 하악 임플란트 피개의치로 수복하여 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

폴리머 시멘트 슬러리 도장철근의 인발부착 특성 (Pullout Bond Characteristics of Polymer Cement Slurry Coated Rebars)

  • 김현기;김민호;장성주;김완기;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.117-122
    • /
    • 2001
  • Recently, epoxy-coated re-bar used to the structure partly and put to practical use step, but not economical and appeared to the defect of deterioration of long term bond strength between concrete. The method for complement the defect of epoxy coated re-bar, study of polymer cement slurry coated re-bar started and basic properties appeared to excellent, but study of bond properties embedded in concrete specimens insufficient until now. This study attempts to examination of using possibility for bond strength of polymer cement slurry coated re-bar between concrete specimens compare to ACI Code and KS Code through pull-out test of 15cm$\times$15cm$\times$15cm specimens with polymer cement slurry coated re-bar as polymer cement ratio 50%, 100%, 150%, coating thickness 250${\mu}{\textrm}{m}$, 440${\mu}{\textrm}{m}$ and curing age. In the results of this study, the bond strength of polymer cement slurry coated re-bar compare to plain re-bar, epoxy coated re-bar decreased St/BA-modified polymer cement slurry coated re-bar, but bond strength of PA-modified polymer cement slurry coated re-bar appeared to excellent results. The bond properties of polymer cement slurry coated re-bar between concrete will be obtain more precise results according to compressive strength change of concrete and re-bar diameter size.

  • PDF

콘크리트 보강용 FRP 리바의 개발 및 내구 특성 (Development and Durability Characteristics of FRP Reinforcing Bar for Concrete Structures)

  • 원종필;박찬기;윤종환;황금식;조용진
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.371-374
    • /
    • 2003
  • The corrosion of steel reinforcing bar(re-bar) has been the major cause of the reinforced concrete deterioration. FRP(Fiber-reinforced polymer) reinforcing bar has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. In this study, long-term durability performance of FRP re-bar were evaluated. The mechanical and durability properties of two type of CFRP- and GFRP re-bar were investigated; the FRP re-bars were subjected to alkaline solution, acid solution, salt solution and deionized water. The mechanical and durability properties were investigated by performing tensile and short beam tests. Experimental results confirmed the desirable resistance of FRP re-bar to aggressive chemical environment.

  • PDF

유한요소법을 이용한 세장비가 큰 가공 소재를 포함한 소형 고속 스핀들 시스템의 바-피더 지지조건에 따른 고유진동 특성 연구 (Natural vibration characteristics of the high speed spindle system with a long workpiece due to supporting conditions of bar-feeders based on using FEM analysis)

  • 이재훈;김무수;박성훈;이시복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2008년도 추계학술대회 논문집
    • /
    • pp.461-462
    • /
    • 2008
  • PDF

A New Method to Find Bars

  • Lee, Yun Hee;Ann, Hong Bae;Park, Myeong-Gu
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.40.1-40.1
    • /
    • 2014
  • We have classified barred galaxies for 418 RC3 sample galaxies within z < 0.01 from SDSS DR7 using the visual inspection, ellipse fitting method and Fourier analysis. We found the bar fraction to be ~60%, 43% and 70% for each method and that the ellipse fitting method tends to miss the bar when a large bulge hides the transition from bar to disk in early spirals. We also confirmed that the Fourier analysis cannot distinguish between a bar and spiral arm structure. These systematic difficulties may have produced the long-time controversy about bar fraction dependence on Hubble sequence, mass and color. We designed a new method to fine bars by analyzing the ratio map of bar strength in polar coordinates, which yields the bar fraction of ~27% and ~32% for SAB and SB, respectively. The consistency with visual inspection reaches around 70%, and roughly 90% of visual strong bar are classified as SAB and SB in our classification. Although our method also has a weakness that a large bulge lowers the value of bar strength, the missing bar fraction in early spirals is reduced to the level of ~1/4 compared to the ellipse fitting method. Our method can make up for the demerits of the previous automatic classifications and provide a quantitative bar classification that agrees with visual classification.

  • PDF

비전 기반 실시간 원거리 2차원 바코드 검출 시스템 (Vision-based Real-Time Two-dimensional Bar Code Detection System at Long Range)

  • 윤인용;김중규
    • 전자공학회논문지
    • /
    • 제52권9호
    • /
    • pp.89-95
    • /
    • 2015
  • 본 논문에서는 비전 기술을 기반으로 원거리에서 2차원 바코드를 검출 할 수 있는 실시간 시스템을 제안한다. 제안된 시스템은 2차원 바코드의 위치 심볼을 찾는 근거리 검출을 먼저 수행하고, 만약 검출이 안 될 경우 원거리 검출로 전환된다. 원거리 검출은 다음과 같은 순서로 진행된다. 먼저 에지 지도, 영상 이진화, CCL(connect component labeling)을 순차적으로 수행하여 관심 영역을 설정한다. 설정된 관심 영역을 Bilinear Interpolation을 이용하여 확대한 후, 근거리 검출과 마찬가지로 위치 심볼 패턴을 검출하여 2차원 바코드 영역을 결정한다. 마지막으로 검출된 패턴 정보를 활용하여 역 투영 변환을 적용하여 패턴을 정렬하게 된다. 실험 결과 제안된 시스템은 기존에 제안된 2차원 검출 알고리즘보다 약 2~3배정도 더 먼 거리의 바코드를 검출 할 수 있음을 보였고, 여러 개의 2차원 바코드 검출이 가능함을 보였다. 또한, 실내의 복잡한 환경에서도 강인한 검출 결과를 보였다.