• Title/Summary/Keyword: Long Axis

Search Result 732, Processing Time 0.03 seconds

A COMPARATIVE STUDY OF THE 1-PIECE AND 2-PIECE CONICAL ABUTMENT JOINT: THE STRENGTH AND THE FATIGUE RESISTANCE

  • Kwon, Taek-Ka;Yang, Jae-Ho;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.780-786
    • /
    • 2007
  • Statement of problem. The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the interface between components has been shown to have a profound influence on the stability of screw joints. Purpose. The Purpose of this study was to compare the strength and the fatigue resistance of 1-piece and 2-piece abutment connected to oral implant, utilizing an internal conical interface. Material and methods. Twenty $Implatium^{(R)}$ tapered implants were embedded to the top of the fixture in acrylic resin blocks. Ten $Combi^{(R)}$(1-piece) and $Dual^{(R)}$(2-piece) abutments of the same dimension were assembled to the implant, respectively. The assembled units were mounted in a testing machine. A load was applied perpendicular to the long axis of the assemblies and the loading points was at the distance of 7mm from the block surface. Half of 1-piece and 2-piece abutment-implant units were tested for the evaluation of the bending strength, and the others were cyclically loaded for the evaluation of the fatigue resistance until plastic deformation occurred. Nonparametric statistical analysis was performed for the results. Results. Mean plastic and maximum bending moment were $1,900{\pm}18Nmm,\;3,609{\pm}106Nmm$ for the 1-piece abutment, and $1,250{\pm}31Nmm,\;2,688{\pm}166Nmm$ for the 2-piece abutment, respectively. Mean cycles and standard deviation when implant-abutment joint showed a first plastic deformation were $238,610{\pm}44,891$. cycles for the 1-piece abutment and $9,476{\pm}3,541$ cycles for the 2-piece abutment. A 1-piece abutment showed significantly higher value than a 2-piece abutment in the first plastic bending moment (p<.05), maximum bending moment (p<.05) and fatigue strength (p<.05). Conclusion. Both 1-piece and 2-piece conical abutment had high strength and fatigue resistance and this suggests long-term durability without mechanical complication. However, the 1-piece conical abutment was more stable than the 2-piece conical abutment in the strength and the fatigue resistance.

Minimum Design Thickness of Prestressed Concrete Deck Slabs for Composite Two-Girder Bridges (강합성 2거더교 프리스트레스트 바닥판의 설계 최소두께)

  • Hwang, Hoon Hee;Joh, Changbin;Kwark, Jong Won;Lee, Yong Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.183-190
    • /
    • 2006
  • Minimizing the self weight of long-span deck slabs is one of the key factors for the practical and economic design of a composite two-girder bridge. In this paper, the minimum design thickness and rebar details of prestressed concrete deck slabs for composite two-girder bridges with girder span length from 4 m to 12 m are studied based on the safety and serviceability. The bridge deck slab with minimum thickness is designed as a one-way slab considering orthotropic behavior. Then fatigue safety of the deck slab is examined. Serviceability requirements for the deck slab such as deflection and crack width limits are also examined. The result shows that rebars with diameter less than 16 mm is recommended for the improved fatigue behavior, and, for the deck slab with span length longer than 8 m, the deflection limit governs the minimum design thickness. The result also shows that, for the deck slab with span length longer than 4 m, the distribution rebar requirement in the current Korea Highway Bridge Design Code is not sufficient to maintain the structural continuity in bridge axis as expected from the deck slab with span length shorter than 3 m.

Ecology of the Black Soldier Fly, Hermetia illucens (Diptera: Stratmyidae) in Korea (국내 서식하는 아메리카동애등에(Hermetia illucens)의 생태 특성)

  • Kim, Jong-Gill;Choi, Young-Cheol;Choi, Ji-Young;Kim, Won-Tae;Jeong, Gil-Sang;Park, Kwan-Ho;Hwang, Sock-Jo
    • Korean journal of applied entomology
    • /
    • v.47 no.4
    • /
    • pp.337-343
    • /
    • 2008
  • This study was conducted to investigate the distribution pattern, ecological characteristics and life cycle of the Black Soldier Fly (Hermetia illucens, BSF). The BSF was widely distributed throughout Korea. The insect was mainly found in the vicinity of and in cattle sheds, manure sheds, living waste dump grounds, and food waste dump grounds. Developmental characteristics of the BSF are as follows: the egg was long oval shaped of 887 ${\mu}m$ in the major axis and 190 ${\mu}m$ in the minor axis; it weighed 24 ${\mu}g$. Female oviposited ca. 1,000 eggs on average; eggs hatched in 81 hours under laboratory condition ($27^{\circ}C$, 60% R.H.). The duration of the larval stage was approximately $15{\sim}20$ days. The size of the last instar larvae was 21 mm. The cuticle of the pupae gradually acquired red-brown color and the size of them was 19 mm. The pupal stage was shorter for females (16 days) than males (15 days). Adults were sized about $13{\sim}20$ mm long and black-colored. The life span of adult insects was $5{\sim}8$ days for the first generation (June${\sim}$July), $7{\sim}10$ days for the second generation (Aug.${\sim}$Sept.), and $13{\sim}18$ days for the third generation (Sept.${\sim}$Oct.). Mating started on the next day of emergence and actively occurred at the third day after emergence. Mating mostly occurred between 10:00 and 16:00 during which light intensity is highest. Egg-laying started on the third day and was most frequent from the fourth to the sixth day after emergence. Similar to mating time, females oviposited mostly between 10:00 and 16:00.

Diagnostic Accuracy of Rest T1-201/Stress Tc-99m-MIBI Myocardial SPECT in the Diagnosis of Coronary Artery Disease (휴식 T1-201/부하 Tc-99m MIBI 심근 SPECT의 관상동맥질환 진단 정확성)

  • Yeo, Jeong-Seok;Lee, Dong-Soo;Kang, Keon-Wook;Sohn, Dae-Won;Oh, Byung-Hee;Lee, Myung-Mook;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.112-117
    • /
    • 1996
  • Objective: Standard stress/rest Tc-99m MIBI and T1-201 myocardial perfusion study have some limitations such as stress/rest image overlap for Tc-99m-MIBI, low energy for T1-201 and long period of study time for two separate studies. Separate acquisition rest T1-201/stress Tc-99m MIBI dual isotope study is a potentially efficient myocardial perfusion imaging protocol that combines the high resolution of Tc-99m for stress perfusion assessment and T1-201 for viability assessment. This study assessed the usefulness and diagnostic accuracy for this new approach. Methods: We tried to evaluate sensitivity and specificity of dual isotope separate acquisition protocol in 67 patients. Immediately after resting T1-201 SPECT data was acquired, dipyridamole stress Tc-99m MIBI myocardial perfusion study was performed. Visual analysis was carried out qualitatively with 0 to 3 scoring system for 17 segments of left ventricle in the reconstructed horizontal long axis and short axis slices. Results: Total study was completed within 3 hours. In angiographic correlation, dual isotope SPECT demonstrated high sensitivity(85%) and in a small group of patients, high specificity was also observed (100%). Conclusion: Combined thallium-201/stress Tc-99m MIBI SPECT displayed similiar diagnostic accuracy to protocol using stress/rest Tc-99m MIBI SPECT. This protocol was completed in shorter period than the previous protocols and therefore enhance laboratory throughput and patients convenience.

  • PDF

Immunohistochemical and Ultrastructural Characterization of the Choline Acetyltransferase-immunoreactive Nerve Cells in the Diagonal Band of Broca of the Rat Basal Forebrains (흰쥐의 전뇌 기저부 대각 Broca대에서 Choline Acetyltransferase 면역반응 신경세포에 대한 면역조직화학 및 미세구조)

  • Back, Seung-Keun;Chung, Young-Wha
    • Applied Microscopy
    • /
    • v.29 no.3
    • /
    • pp.383-403
    • /
    • 1999
  • This study was performed to investigate the immunohistochemical and ultrastructural characterization of the choline acetyltransferase (ChAT)-immunoreactive nerve cells in the diagonal band of Broca of the rat basal forebrains, utilizing techniques of immunohistochemical and immunocytochemical microscopy. The ChAT-immunoreactivities were shown within neuronal cell bodies and processes by the light micoscope. According to cell shape and ratio of long axis vs short axis of cell body, the ChAT-immunoreaclive nerve cells in both vertical and horizontal limbs of the diagonal band of Broca were classified into 6 types. at the light microscopic level; round, oval, elongated, fusiform, triangular and polygonal types. As a result of the electron microscopic observation, the ChAT-immunoreactivated products appeared on the outer nuclear envelope, membranes of rough endoplasmic reticula (rER), free ribosomes and polysomes. Each cell type was subdivided into subtype I and II according to the several criteria such as volume of cell body, nuclear size relative to the cytoplasm, kinds and distribution of cell organelles and numbers and sorts of synapses. The subtype I of immnunoreactive nerve cells had large cell body and a small nucleus showing shallow indentations of nuclear evelope. In this subtype I with abundant cytoplasm, rER were well differentiated. Their long cisternae were parallelly ditributed and lamellated. One or two lamellar bodies and nematosomes were observed. The subtype II cell had small cell body and a large nucleus with deep indentations of nuclear envelope. In this subtype II with small cytoplasm, the rER were irregularly distributed and the lamellar body and nematosome were not found. A few axosomatic synapses in the subtype I and II were shown to be symmetric or asymmetric. The ratios of the symmetric synapse to the asymmetric one were investigated to be 1 : 2 and 1 : 4 in the subtype I and II, respectively. The axodendritic ones were almost asymmetric. But, the fusiform and triangular immunoreactive nerve cells were shown only to be subtype I. According to observations in this study, it is considered that the ultrastructural characterization in the 2 subtypes of each cell type may reflect the differences of the metabolic activities and projecting distances to the target cells.

  • PDF

A study on the change of head posture and hyoid bone position before and after rapid maxillary expansions (상악골 급속확장술식 전후 두경부 자세와 설골위치의 변화에 관한 연구)

  • Bae, Hyeon-Cheol;Lee, Jin-Woo;Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.569-584
    • /
    • 1997
  • The present study assessed the effects of Rapid Maxillary Expansion on head posture and hyoid bone position. For this study, 32 Angle's class III patients - hellman 3c $\~$ adult stage, mean age 12y9m - were selected and divided into two groups, A,B according to craniocervical angulation. Craniocervical angulation Increased in Group A and decreased in Group B after the therapy. And 23 Angle's class I persons $\~$ same hellman stage, mean age 12y7m $\~$ were selected (or the control group. Cephalometric analysis of skeletal pattern, pharyngeal space, head posture, hyoid bone position was performed. The results were as follows, 1. Comparison of skeletal pattern and pharyngeal space 1) All two groups(A,B) had Mandibular plane inclined inferiorly and no pharyngeal space change was obseved after RME therapy 2) Skeletal pattern and pharyngeal space of Group A, B were normal before and after treatment. 2. Comparison of head posture 1) Craniocervical angulation of Group A was increased after treatment. That of Group B was decreased and mandibular plane was inclined inferiorly after treatment. 2) Before treatment, craniocervical inclination was normal in Group A but larger than normal in Group B. After treatment, all two groups(A, B) had normal craniocervical angulation. 3. Comparison of hyoid bone position 1) After treatment, long axis of hyoid in Group A, B was not changed. Antero- posteriorly, hyoid position was changed posteriorly in Group A but no change was founded in Group B after treatment. Vertically, hyoid bone position were not changed in two groups except increase in APHFH in Group A after treatment 2) Long axis of hyoid bone was normal in Group A, B before and after treatment. Anteroposteriorly, hyoid bone position was more anterior than Group B, C before treatment but all the position of two groups had normal position after treatment. Vertical position of hyoid bone was normal in all two groups before and after treatment.

  • PDF

Patient's Selection for Extracorporeal Shock Wave Lithotripsy for Treatment of Common Bile Duct Stones Resistant to Endoscopic Extraction (체외충격파쇄석술 적용을 위한 총담관결석의 선택)

  • Lee, Won-Hong;Son, Soon-Yong;Kim, Chang-Bok;Park, Cheon-Kyoo;Kang, Seong-Ho;Ryu, Meung-Sun;Lee, Yong-Moon
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.105-110
    • /
    • 2005
  • Background/Aim : Common bile duct (CBD) stones may cause jaundice, cholangitis, or pancreatitis. Extracorporeal shock wave lithotripsy (ESWL) may be needed whenever endoscopic procedure are failed to extract common bile duct stones. The aim of this study is to provide the standard for patient's best choice on ESWL for treatment of CBD stones resistant to endoscopic extraction. Materials and Methods : Fourty-six patients failed in endoscopic stone extraction including mechanical lithotripsy were treated by ESWL. In all patients, endoscopic sphincterotomy and nasobiliary drainage tube was done before ESWL using the ultrasonography for stone localization with a spark-gap type lithotriptor. Patients were sedated with an intravenous injection of 50 mg of Demerol. None were treated under general anesthesia. Results : Overall complete clearance rate of CBD stone was 89.1% (41/46). In 82.6% of the patients, the stones were extracted endoscopically after ESWL, and spontaneous passage was observed in 6.5%. In the clearance rate after ESWL, there were no noticeable differences with regard to number (single: 82.8%, two or three: 100%, more than three: 100%) and size of the stone (less than 33mm: 92.9%, 33 mm or larger: 83.3%), whereas there were significant differences with regard to the ratio of sum of long-axis length of the all stones to sum of long-axis length of the CBD excluding stone (1:2.4, 1:2.1) and diameter of the largest stone to diameter of CBD excluding stone (1:0.9, 1:0.4) for patients with complete clearance compared with those without. Conclusion : We propose that stones without the fragments are travelable sufficient space in CBD or extractable sufficient diameter of CBD regardless of stone size and number should be treated by other technique to prevent time and cost consuming, such as percutaneous transhepatic cholangioscopylithotomy.

  • PDF

An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera (동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰)

  • Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.75-79
    • /
    • 2019
  • Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

CT Evaluation of Long-Term Changes in Common Bile Duct Diameter after Cholecystectomy (담낭 절제술 후 총담관 직경의 장기 변화에 대한 CT 평가)

  • Sung Hee Ahn;Chansik An;Seung-seob Kim;Sumi Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.581-595
    • /
    • 2024
  • Purpose The present study aimed to investigate the frequency and extent of compensatory common bile duct (CBD) dilatation after cholecystectomy, assess the time between cholecystectomy and CBD dilatation, and identify potentially useful CT findings suggestive of obstructive CBD dilatation. Materials and Methods This retrospective study included 121 patients without biliary obstruction who underwent multiple CT scans before and after cholecystectomy at a single center between 2009 and 2011. The maximum short-axis diameters of the CBD and intrahepatic duct (IHD) were measured on each CT scan. In addition, the clinical and CT findings of 11 patients who were initially excluded from the study because of CBD stones or periampullary tumors were examined to identify distinguishing features between obstructive and non-obstructive CBD dilatation after cholecystectomy. Results The mean (standard deviation) short-axis maximum CBD diameter of 121 patients was 5.6 (± 1.9) mm in the axial plane before cholecystectomy but increased to 7.9 (± 2.6) mm after cholecystectomy (p < 0.001). Of the 106 patients with a pre-cholecystectomy axial CBD diameter of < 8 mm, 39 (36.8%) showed CBD dilatation of ≥ 8 mm after cholecystectomy. Six of the 17 patients with long-term (> 2 years) serial follow-up CT scans (35.3%) eventually showed a significant (> 1.5-fold) increase in the axial CBD diameter, all within two years after cholecystectomy. Of the 121 patients without obstruction or related symptoms, only one patient (0.1%) showed IHD dilatation > 3 mm after cholecystectomy. In contrast, all 11 patients with CBD obstruction had abdominal pain and abnormal laboratory indices, and 81.8% (9/11) had significant dilatation of the IHD and CBD. Conclusion Compensatory non-obstructive CBD dilatation commonly occurs after cholecystectomy to a similar extent as obstructive dilatation. However, the presence of relevant symptoms, significant IHD dilatation, or further CBD dilatation 2-3 years after cholecystectomy should raise suspicion of CBD obstruction.

Changes in atlas position with Class ll activator treatment in Class II malocclusion patients (II급 부정교합자에서 액티베이터 사용에 따른 atlas의 위치 변화에 관한 연구)

  • Cho, Moon-Ki;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.44-55
    • /
    • 2007
  • Objective: Previous studies have reported that morphological features of the first cervical vertebra (atlas) have been associated with mandibular growth direction. The purpose of this study was to show the possible positional and morphological changes of the Atlas from activator treatment in Class II malocclusion patients. Methods: Lateral cephalometric radiograph tracings were made at initial, middle and final stages of treatment. Angular and linear measurements of skeletal and morphological features were measured on the anatomical landmarks and reference planes. Results: The skeletal effects of activator treatment on Class II malocclusion patients were evident on ramal height, body length, effective body length, ANB, and overjet. Clockwise rotation of the long axis of the Atlas was found in Group 1, but there was no inclination change of the Atlas in groups 2 and 3. There was no significant correlation between anterior and posterior positions of the atlas or morphological change in all groups. - except for posterior movements of the Atlas found in group 1. Conclusion: Clockwise rotation of the atlas axis resulted from activator treatment in Cl II malocclusion patients. Change in atlas axis can be thought of as an indicator for success of activator treatment.