• 제목/요약/키워드: Long Axis

검색결과 732건 처리시간 0.028초

Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture

  • Bowley, John Francis;Kaye, Elizabeth Krall;Garcia, Raul Isidro
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.278-286
    • /
    • 2017
  • PURPOSE. The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS. Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS. Low levels of vertical wall taper, ${\leq}10-degrees$, were needed to resist rotational displacement in all wall height categories; 2-to-6-degrees is generally considered ideal, with 7-to-10-degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION. The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form.

Analysis of the root position and angulation of maxillary premolars in alveolar bone using cone-beam computed tomography

  • Yun-Hoa, Jung;Bong-Hae, Cho;Jae-Joon, Hwang
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.365-373
    • /
    • 2022
  • Purpose: This study investigated whether the relationship between the maxillary sinus and the root of the maxillary premolar is correlated with the root position and whether there is a difference in the long axis angle of premolars and the buccal bone thickness according to the sinus-root relationship and root position. Materials and Methods: Cone-beam computed tomographic images of 587 maxillary first premolars and 580 second premolars from 303 patients were retrospectively reviewed. The maxillary sinus floor-root relationship was classified into 4 types, and the root position in the alveolar bone was evaluated as buccal, middle, or palatal. The long axis angle of the maxillary premolars in the alveolar bone and the buccal bone thickness were measured. The correlation between these parameters was analyzed. Results: The maxillary sinus floor-root relationship showed a statistically significant correlation with the root position in the alveolar bone. Most maxillary first premolars were buccally located, and more than half of the second premolars had their roots in the middle. The long axis angle of the premolars was significantly larger in buccal-positioned teeth than in middle-positioned teeth, and the buccal bone was thinner. Conclusion: When the root of the maxillary premolar was separated from the sinus floor, the premolar was often located on the buccal side. Most of the maxillary first premolars had a thinner buccal bone and larger inclination than the second premolars. It is recommended to evaluate the root position, sagittal angle and buccal bone thickness using CBCT for implant treatment planning.

Morphological Changes in the Mandibular Condyle Following Botulinum Toxin Injection into the Human Masseter Muscle

  • Younjung Park;Junghoon Hong;Hyok Park;Naoya Kakimoto;Seong Taek Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제48권1호
    • /
    • pp.16-24
    • /
    • 2023
  • Purpose: To determine the effects of botulinum toxin (BoNT) injection into the human masseter muscle on the morphology of the mandibular condyle bone using cone-beam computed tomography (CBCT). Methods: Twenty volunteers were randomly assigned to one of two groups. Group I received a single BoNT injection; Group II received two injections, with the second being administered 4 months after the first. CBCT scans of both temporomandibular joints (TMJs) were performed before and 6 months after the first injection. Bony changes in the cortical layers of the condyle heads were evaluated and the long and short axes of both mandibular condyles were measured. The thickness at the thinnest part of glenoid fossa was also quantitatively measured. Results: There was no significant difference between pre- and post-injection CBCT images. Furthermore, no changes in the cortical layers of the condyle heads were observed among the subjects who exhibited mild degenerative TMJ changes. The quantitative measurements (long axis, short axis, and the thickness of thinnest part of glenoid fossa roof) did not differ significantly between pre- and post-injection except for the long axis in Group I. Conclusions: Within the limitations of this study, it appears that BoNT injections into human masseter muscles do not alter the morphology of the mandibular condyle bone in healthy adults.

신생아 모발 표면을 둘러싸고 있는 비늘에 관한 주사전자현미경적 연구 (Scanning Electron Microscopic Study of Scales Surrounding the Surface of Newborn Hair)

  • 정희중;진현숙;장아영;장은주;장병수;김경숙
    • 융합정보논문지
    • /
    • 제10권5호
    • /
    • pp.216-223
    • /
    • 2020
  • 본 연구는 신생아 두피 모발의 기저부에서부터 말단부위까지의 외부형태와 모발 가로 직경 대비 모발 표면에 노출된 비늘의 장축 직경 비율을 주사전자현미경으로 관찰하였다. 신생아 모발은 두피에 인접한 부위에서 부터 모발의 끝부분으로 갈수록 완만하게 가늘어지는 것을 확인하였다. 본 연구에서 모발의 두께가 커질수록 노출된 비늘의 장축 직경 비율은 상대적으로 작아지는 것으로 확인되었지만 모발 표면의 노출된 비늘 장축 직경은 모발의 굵기에 관계없이 비슷한 길이로 나타났다. 결론적으로 가는 모발이나 굵은 모발 표면에 노출된 비늘의 장축 직경은 크게 변화하지 않는 것을 확인하였다.

Touchpad for Force and Location Sensing

  • Kim, Dong-Ki;Kim, Jong-Ho;Kwon, Hyun-Joon;Kwon, Young-Ha
    • ETRI Journal
    • /
    • 제32권5호
    • /
    • pp.722-728
    • /
    • 2010
  • This paper presents the design and fabrication model of a touchpad based on a contact-resistance-type force sensor. The touchpad works as a touch input device, which can sense contact location and contact force simultaneously. The touchpad is 40 mm wide and 40 mm long. The touchpad is fabricated by using a simple screen printing technique. The contact location is evaluated by the calibration setup, which has a load cell and three-axis stages. The location error is approximately 4 mm with respect to x-axis and y-axis directions. The force response of the fabricated touchpad is obtained at three points by loading and unloading of the probe. The touchpad can detect loads from 0 N to 2 N. The touchpad shows a hysteresis error rate of about 11% and uniformity error rate of about 3%.

A Tilt and Heading Estimation System for ROVs using Kalman Filters

  • Ha, Yun-Su;Ngo, Thanh-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권7호
    • /
    • pp.1068-1079
    • /
    • 2008
  • Tilt and heading angles information of a remotely operated vehicle (ROV) are very important in underwater navigation. This paper presents a low.cost tilt and heading estimation system. Three single.axis rate gyros, a tri-axis accelerometer, and a tri-axis magnetometer are used. Output signals coming from these sensors are fused by two Kalman filters. The first Kalman filter is used to estimate roll and pitch angles and the other is for heading angle estimation. By using this method, we have obtained tilt (roll and pitch angles) and heading information which are reliable over long period of time. Results from experiments have shown the performance of the presented system.

배율 타원 근사법을 실린더 렌즈의 굴절력 측정 (Measurement of the Power of a Cylindrical Lens with the Magnification Ellipse Fitting Method)

  • 고우석;예상헌;곽윤근;김수현
    • 한국정밀공학회지
    • /
    • 제25권2호
    • /
    • pp.43-48
    • /
    • 2008
  • This paper proposes a new method for measuring the power of spherical and cylindrical lens with 6 points light source, which is composed of a LED and six holes, and magnification ellipse fitting algorithm. Each measured diagonal length of 6 points light source is determined by the target lens power. After finding the center position of each light point with threshold method, 3 axis-diagonal lengths were calculated. The long axis and short axis power of cylindrical lens can be calculated by using magnification ellipse fitting algorithm with the magnification relationships between the initial diagonal lengths and the measured diagonal lengths changed by lens power.

홀로그래피를 이용한 분무 액적의 3차원 속도 측정 (Measurements of Three-Dimensional Droplet Velocities Using the Holographic System)

  • 오대진;추연준;강보선
    • 한국분무공학회지
    • /
    • 제6권4호
    • /
    • pp.31-38
    • /
    • 2001
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, the holographic panicle velocimetry system was used to measure the sizes and velocities of droplets formed by a commercial full cone spray nozzle. Uncertainty analysis was performed to identify the sources of all relevant errors and to evaluate their magnitude. The droplet velocities ranged from 10.3 to 13.3 m/s with average uncertainty of ${\pm}1.6m/s$, which is ${\pm}14%$ of the mean droplet velocity. Compared with relatively small uncertainties of velocity components in the normal direction to the optical axis, the uncertainty of the optical axis component is ${\pm}3.6m/s$. This is due to the long depth of field of droplet images in the optical axis, which is inherent feature of holographic system using forward-scattering object wave of particles.

  • PDF

3축선반에서의 스크류 가공을 위한 CAM 시스템 개발 (Development of a CAM System for 3-Axis NC Machining for Screws)

  • 이원규;안중환
    • 한국정밀공학회지
    • /
    • 제15권2호
    • /
    • pp.21-27
    • /
    • 1998
  • NC machining of large screw which is usually used as a part in an extruder for injection molding is done on 3-axis turning machine, and it is very time-consuming process. Not only in machining but in preparing part program for a NC machine, it requires very long time because the shape of the screw is not easy to model when using an existing general CAD/CAM software even though it is workstation level software. In addition, tool path generation procedure for NC turning for screw shape is also very tedious one because large amount of data for cutter location point must be produced and there is no specific CAM software for the machining. In this paper. development of a CAM system for screw machining which saves the role of CAD software by use of menu driven data input system for various screw shapes is introduced.

  • PDF

초정밀 3축 이송 스테이지의 개발 :2. 동특성 실험 및 성능 평가 (Development of a 3-axis fine positioning stage : Part 2. Experiments and performance evaluation)

  • 강중옥;김만달;백석;한창수;홍성욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1207-1210
    • /
    • 2003
  • This paper deals with experiments for dynamic characteristics and performance evaluation of the 3-axis fine positioning stage developed in [1]. The features of the developed fine positioning stage are the long stroke due to the magnetically preloaded PZT actuators, the minimum motion crosstalk due to the use of a ball contact mechanism and the compact design. The dynamic characteristics of the actuator and the stage are tested with the preload changed in order to validate the actuator and the stage design. Performance evaluation is also made for the PZT actuators as well as the stage positioning accuracy. Experimental results show that the developed stage is accurate enough to be used for nanometer positioning.

  • PDF