• Title/Summary/Keyword: Log-Structure

Search Result 351, Processing Time 0.029 seconds

Collapsibility Using Raindrop Plot (RAINDROP PLOT을 이용한 차원축소)

  • Hong C. S.;Kim B. J.;Park J. Y.
    • The Korean Journal of Applied Statistics
    • /
    • v.18 no.2
    • /
    • pp.471-485
    • /
    • 2005
  • For categorical data analysis, the collapsibility were explained with the odds ratio (cross-product ratio). When these theories with these odds ratios are applied to real $2{\times}2{\times}K$ contingency tables, it is impossible to decide whether data are collapsible. Among graphical methods to represent odds ratios, Contour plot which is developed by Doi, Nakamura and Yamamoto (2001) could explain the structure of these data, but cannot decide on the collapsibility. In this paper, by using the Raindrop plot proposed by Barrowman and Myers (2003), we suggest an alternative method which can not only explain the structure of data, but also decide on the collapsibility.

Earthquake risk assessment of seismically isolated extradosed bridges with lead rubber bearings

  • Kim, Dookie;Yi, Jin-Hak;Seo, Hyeong-Yeol;Chang, Chunho
    • Structural Engineering and Mechanics
    • /
    • v.29 no.6
    • /
    • pp.689-707
    • /
    • 2008
  • This study presents a method to evaluate the seismic risk of an extradosed bridge with seismic isolators of lead rubber bearings (LRBs), and also to show the effectiveness of the LRB isolators on the extradosed bridge, which is one of the relatively flexible and lightly damped structures in terms of seismic risk. Initially, the seismic vulnerability of a structure is evaluated, and then the seismic hazard of a specific site is rated using an earthquake data set and seismic hazard maps in Korea. Then, the seismic risk of the structure is assessed. The nonlinear seismic analyses are carried out to consider plastic deformation of bridge columns and the nonlinear characteristics of soil foundation. To describe the nonlinear behaviour of a column, the ductility demand is adopted, and the moment-curvature relation of a column is assumed to be bilinear hysteretic. The fragility curves are represented as a log-normal distribution function for column damage, movement of superstructure, and cable yielding. And the seismic hazard at a specific site is estimated using the available seismic hazard maps. The results show that in seismically-isolated extradosed bridges under earthquakes, the effectiveness of the isolators is much more noticeable in the columns than the cables and girders.

A Design for a Hyperledger Fabric Blockchain-Based Patch-Management System

  • Song, Kyoung-Tack;Kim, Shee-Ihn;Kim, Seung-Hee
    • Journal of Information Processing Systems
    • /
    • v.16 no.2
    • /
    • pp.301-317
    • /
    • 2020
  • An enterprise patch-management system (PMS) typically supplies a single point of failure (SPOF) of centralization structure. However, a Blockchain system offers features of decentralization, transaction integrity, user certification, and a smart chaincode. This study proposes a Hyperledger Fabric Blockchain-based distributed patch-management system and verifies its technological feasibility through prototyping, so that all participating users can be protected from various threats. In particular, by adopting a private chain for patch file set management, it is designed as a Blockchain system that can enhance security, log management, latest status supervision and monitoring functions. In addition, it uses a Hyperledger Fabric that owns a practical Byzantine fault tolerant consensus algorithm, and implements the functions of upload patch file set, download patch file set, and audit patch file history, which are major features of PMS, as a smart contract (chaincode), and verified this operation. The distributed ledger structure of Blockchain-based PMS can be a solution for distributor and client authentication and forgery problems, SPOF problem, and distribution record reliability problem. It not only presents an alternative to dealing with central management server loads and failures, but it also provides a higher level of security and availability.

A Case of Seasonal Affective Disorder with Hypersomnia -Polysomnographic Findings Before and After Light Therapy- (과수면을 수반한 계절성 정동장애 1례 -광치료 전후의 수면다원검사 소견을 중심으로-)

  • Joe, Sook-Haeng;Kim, Leen;Suh, Kwang-Yoon
    • Sleep Medicine and Psychophysiology
    • /
    • v.5 no.2
    • /
    • pp.202-209
    • /
    • 1998
  • Authors report the findings of nocturnal polysomnography and multiple sleep latency test(MSLT) before and after morning light treatment in a winter depressive patient with hypersomnia. On polysomnographic recordings, the sleep pattern of this case before light treatment was similar to that of narcolepsy exhibited, sleep onset REM period(SOREMP). After treatment, the shortened REM latency changed to normal condition, but, deep sleep percentage did not changed, and stage 4 sleep percentage was decreased. Depressive symptoms were improved on clinical interview with Hamilton Depressive Rating Scale. Sleep log showed shortened sleep latency and reduced sleep duration. These findings suggest that although light treatment could alter the sleep structure in seasonal affective disorder with hypersomnia, it does not necessarily imply that antidepressant response of light treatment is result of change of sleep structure.

  • PDF

EFFECTS OF COLLISIONAL DE-EXCITATION ON THE RESONANCE DOUBLET FLUX RATIOS IN SYMBIOTIC STARS AND PLANETARY NEBULAE

  • Kang, Eun-Ha;Lee, Hee-Won
    • Journal of The Korean Astronomical Society
    • /
    • v.41 no.3
    • /
    • pp.49-58
    • /
    • 2008
  • Resonance doublets including O VI 1032, 1038, NV 1239, 1243 and C IV 1548, 1551 constitute prominent emission lines in symbiotic stars and planetary nebulae. Spectroscopic studies of symbiotic stars and planetary nebulae from UV space telescopes show various line ratios of these doublets deviating from the theoretical ratio of 2:1. Using a Monte Carlo technique, we investigate the collisional de-excitation effect in these emission nebulae. We consider an emission nebula around the hot component of a symbiotic star characterized by the collisional de-excitation probability $p_{coll}\;{\sim}\;10^{-3}\;-\;10^{-4}$ per each resonance scattering, and the line center optical depths for major resonance doublets in the range ${\tau}_0\;{\sim}\;10^2\;-\;10^5$. We find that various line ratios are obtained when the product $p_{coll}{\tau}_0$ is of order unity. Our Monte Carlo calculations show that the flux ratio can be approximately fitted by a linear function of ${\log}{\tau}_0$ when ${\tau}_0p_{coll}\;{\sim}\;1$. It is briefly discussed that this corresponds to the range relevant to the emission nebulae of symbiotic stars.

Correlation between the Trend toward Higher Temperature and Land Cover Structure in Haeundae District of Busan in Summer (부산시 해운대구의 하기 도시 고온화 현상과 토지피복 구성과의 상관관계)

  • Yoon, Seong-Hwan;Kim, Seong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.19-27
    • /
    • 2008
  • This study aims at examining the correlation between air temperature and urban structure such as land cover. For this, it measured summer air temperature by using data log type thermometer installed the inside of instrument screen, in the 9 points of elementary school in Haeundae, Busan. The accomplished results of this study are followings. 1) As altitude goes up 100m, air temperature drops to $0.6{\sim}1.0^{\circ}C$. 2) As building coverage ratio increases 10%, air temperature increases $0.3{\sim}0.4^{\circ}C$. 3) As floor space index increases 100%, air temperature increases $0.4{\sim}0.5^{\circ}C$. 4) As artificial coverage ratio increases 10%, air temperature increases $0.1{\sim}0.2^{\circ}C$. 5) As natural coverage ratio increases 10%, air temperature decreases $0.1{\sim}0.2^{\circ}C$.

Reliability testing of InGaAs Waveguide Photodiodes for 40-Gbps Optical Receiver Applications (40-Gbps급 InGaAs 도파로형 포토다이오드의 신뢰성 실험)

  • Joo, Han-Sung;Ko, Young-Don;Yun, Il-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.13-16
    • /
    • 2004
  • The reliability of 1.550m-wavelength InGaAs mesa waveguide photodiodes(WGPDs), which developed for 40-Gbps optical receiver applications, fabricated by metal organic chemical vapor deposition is investigated. Reliability is examined by both high-temperature storage tests and the accelerated life tests by monitoring dark current and breakdown voltage. The median device lifetime and the activation energy of the degradation mechanism are computed for WGPD test structures. From the accelerated life test results, the activation energy of the degradation mechanism and median lifetime of these devices in room temperature are extracted from the log-normal failure model by using average lifetime and the standard deviation of that lifetime in each test temperature. It is found that the WGPD structure yields devices with the median lifetime of much longer than $10^6$ h at practical use conditions. Consequently, this WGPD structure has sufficient characteristics for practical 40-Gbps optical receiver modules.

  • PDF

Study on Correlation between Large Earthquake-Induced Underground Structure Uplift and Geological Settings (대지진에 의한 지하구조물 부상과 지질학적 특성의 상관성 연구)

  • Kang, Gi-Chun;Kim, Ji-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.9-16
    • /
    • 2016
  • During the 2004 Niigata-ken Chuetsu, Japan, earthquake, more than 1,450 underground structures, known as sewer manhole, were uplifted up to 1.5m in Nagaoka and Ojiya city. The uplift damage can be a serious matter because they not only hinder the flow of wastewater systems, as a part of lifeline systems, but also disturb traffic flows. For restoration works, an open-cut investigation of damaged wastewater system was conducted by the Nagaoka city government. The results from the investigation compiled valuable data sets for buried pipeline damage due to earthquakes. In the present study, the factors affecting the uplift amount of the underground structure is investigated by using the data sets which include locations of damaged sections and inclination of pipeline before and after the earthquake and the SPT borehole logs in the affected area. Correlation analysis between the underground structure uplift and the geological settings in the affected area revealed that ground water depth and original subsoil, including thickness of clay layer, SPT N-value and fill thickness are the key parameters for the uplift phenomenon.

The Study of Restoring Silsangsa Wooden Pagoda (실상사 목탑의 복원 연구)

  • Kim, Kyeong-Pyo
    • Journal of architectural history
    • /
    • v.16 no.6
    • /
    • pp.7-26
    • /
    • 2007
  • This article is about restoring the wooden pagoda which located in Silsangsa Temple after historical research. The process of this study, first of all, the theoretical study was considered about similar examples of wooden pagoda and gilt-bronze pagoda in Gorye period and wooden pagoda in contemporary period. After that, the study was established by the present condition of Silsangsa wooden pagoda site, the characteristic of Silsangsa wooden pagoda, the form of arrangement, the scale and height. Finally, considering those studies, the wooden pagoda designed in detail. This restoring design tried to follow the inference in that time. Moreover, the design tried to involve the elements of characteristic of region and Silsangsa wooden pagoda. Therefore, the research establish period of Silsangsa wooden pagoda in Gorye period. Locally, it considered both elements of Silla and Baeckje. The arrange form of restoring wooden pagoda was freestyle arrangement that had two main building of a temple and one middle pagoda. The idea of structure was to establish of double Core system. This system inferred from the system of building structure in ancient wooden pagoda and middle and modern age of multistory wooden construction. According to measurement of foundation stone, the scale of restoring wooden pagoda followed the skill of Tang-scale. The connection structure of each floor followed laminated structure which was the general form of log frame in that time. After study of foundation's condition, the present writer deseeded to have restoring the wooden pagoda 9 stories tall. The final aim was to depend on the structural intuition of the present writer, the writer tried to restore beautiful wooden pagoda according to in those days which is solution for contradiction of unclear point. So, it could be make out a plane of restoring wooden pagoda.

  • PDF

Decomposition Analysis of Energy Use for Water Supply: From the Water-Energy Nexus Perspective (물 공급을 위한 에너지 사용 요인분해 분석: Water-Energy Nexus 관점에서)

  • Yoo, Jae-Ho;Jo, Yeon Hee;Kim, Hana;Jeon, Eui Chan
    • Journal of Korean Society on Water Environment
    • /
    • v.38 no.5
    • /
    • pp.240-246
    • /
    • 2022
  • Water and energy are inextricably linked and referred to as 'Water-Energy Nexus'. Recently, this topic has been drawing a lot of attention from various studies due to the exacerbated water availability. Korea's water and energy consumption has been increasing consistently, which calls for better management. This paper aims to identify changes in electricity consumption in relation to water intake and purification processes. Using Log Mean Divisia Index (LMDI) Decomposition Analysis method, this study attributes the changes to major factors such as; Total population (population effect), household/population (structure effect), GDP/household (economic effect), and water-related energy use/GDP (unit effect). The population effect, structure effect, and economic effect contributed to an increase in water-related electricity consumption, while the unit effect contributed to a decrease. As of 2019, the economic effect increased the water supply sector's electricity consumption by 534 GWh, the population effect increased by 73 GWh, and the structure effect increased by 243 GWh. In contrast, the unit effect decreased the electricity consumption by -461 GWh. We would like to make the following suggestions based on the findings of this study; first, the unit effect must be improved by increasing the energy efficiency of water intake and purification plants and installing renewable energy power generation facilities. Second, the structure effect is expected to increase over time, and to mitigate it, water consumption must be reduced through water conservation policies and the improvement of water facilities. Finally, the findings of this study are expected to be used as foundational data for integrated water and energy management.