• 제목/요약/키워드: Locomotive

검색결과 272건 처리시간 0.034초

센서 데이터를 이용한 전기 기관차의 이상 상태 요인분석 (Failure Analysis to Derive the Causes of Abnormal Condition of Electric Locomotive Subsystem)

  • 소민섭;전홍배;신종호
    • 산업경영시스템학회지
    • /
    • 제41권2호
    • /
    • pp.84-94
    • /
    • 2018
  • In recent years, the diminishing of operation and maintenance cost using advanced maintenance technology is attracting many companies' attention. Especially, the heavy machinery industry regards it as a crucial problem since a failure of heavy machinery requires high cost and long downtime. To improve the current maintenance process, the heavy machinery industry tries to develop a methodology to predict failure in advance and to find its causes using usage data. A better analysis of failure causes requires more data so that various kinds of sensor are attached to machines and abundant amount of product usage data is collected through the sensor network. However, the systemic analysis of the collected product usage data is still in its infant stage. Many previous works have focused on failure occurrence as statistical data for reliability analysis. There have been less works to apply product usage data into root cause analysis of product failure. The product usage data collected while failures occur should be considered failure cause analysis. To do this, this study proposes a methodology to apply product usage data into failure cause analysis. The proposed methodology in this study is composed of several steps to transform product usage into failure causes. Various statistical analysis combined with product usage data such as multinomial logistic regression, T-test, and so on are used for the root cause analysis. The proposed methodology is applied to field data coming from operated locomotive and the analysis result shows its effectiveness.

고속열차 산천 전장품 발열특성 측정 (Measurement of Thermal Characteristics of Electric Unit for Sancheon High-Speed Railcar)

  • 박원희;윤수환;박춘수
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.3672-3679
    • /
    • 2015
  • 열차 운행에 따른 전장품들의 발열을 예측하기 위해 동력차 내 벽면온도 및 외부 유출 온도 및 풍속, 외부로부터 유입되는 유입 공기의 유입 온도 및 속도를 측정하였다. 이를 위하여 적외선카메라를 이용하여 고속열차 내부의 전장품 및 벽 표면의 온도를 측정하였다. 또한 전장품에서 발생하는 열은 고속열차 천장에 설치된 덕트를 통하여 외부로 배출된다. 배출되는 공기의 온도 및 속도를 측정하였고, 외부에서 동력차 내부로 들어오는 유입공기의 온도 및 속도도 측정하였다. 또한 부착형 온도센서를 이용하여 동력차 내부의 벽 및 전장품 표면에서의 온도를 측정하였다. 측정된 결과를 이용하여 열차 주행에 따른 전장품의 발열 특성을 분석하였다.

디젤전기기관차의 공압제동 영향인자 및 특성 분석 (Analysis of pneumatic braking component effects and characteristics of a diesel electric locomotive)

  • 최돈범;김민수
    • 한국산학기술학회논문지
    • /
    • 제19권11호
    • /
    • pp.541-549
    • /
    • 2018
  • 본 연구에서는 국내 화물 및 여객차량들을 견인하는 디젤전기 기관차의 제동에 따른 동적 거동을 분석하기 위하여 제동장치에 영향을 미치는 마찰계수, 제동압력, 주행저항 등을 시험하였다. 마찰계수는 UIC 541-4를 참고로 Dynamo 시험을 수행하였으며 시험결과는 다변량 회귀분석을 통해 제동하중, 제동초기 속도와의 관계를 분석하여 제시하였다. 제동압력은 상용제동과 비상제동으로 구분하였으며, 제동밸브와 배관의 특성을 반영하기 위하여 시간에 따른 제동압력 변화를 대상 차량에서 측정하였다. 차량에 작용하는 외력을 반영하기 위하여 EN 14067-4의 타행시험을 수행하고 2차 다항식 형태의 주행저항을 제시하였다. 도출한 주행저항을 동일 차종에 대하여 각 국가별로 사용하고 있는 주행저항들과 비교하였다. 차량의 재원, 마찰계수, 제동압력, 주행저항을 바탕으로 직선 평탄 선로를 주행하는 디젤전기기관차의 동적 거동을 EN 14531-1에서 제시된 시간적분을 이용하여 해석하였다. 해석 결과는 상용제동과 비상제동에 대하여 각각 차량의 속도이력 시험결과와 비교 검증하였으며 상당히 합리적인 결과를 도출하였다. 본 연구의 결과들은 철도차량들을 연결하여 운행하는 열차의 동적 거동해석에 활용할 수 있을 뿐 아니라 차량 설계에서 제동에 영향을 미치는 다양한 파라미터들을 분석하고 성능향상의 기초자료로 활용할 수 있을 것으로 기대된다.

KTX 차량의 주행안정성 평가를 위한 노상과 PSC 교량 상의 윤하중분포 동적해석 연구 (A Study of Dynamic Analysis of Wheel Force Spectrum between Road and PSC Bridge tracks for the KTX Safety Evaluation)

  • 이동준;오순택;심영우;윤준관;김한수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.793-799
    • /
    • 2011
  • A comprehensive analysis of wheel force spectrum is conducted to provide the KTX safety evaluation with structural behaviour of Pre-Stressed Concrete (PSC) box bridge due to various high speeds. The wheel spectrum for KTX locomotive running over road and PSC bridge tracks is compared using irregular track responses with numerical models of 170m approach road track and 40m span length of PSC box bridge The high-speed railway locomotive is used as 38-degree of freedom system. Three displacements (vertical, lateral, and longitudinal) and three rotational components (pitching, rolling, and yawing) for one car-body and two bogies are considered in the 38-degree of freedom model. Three dimensional frame element of finite element method (FEM) is used to model of the simply supported PSC box bridge. The irregulation of rail-way is derived using the experiential spectrum density function under assumption of twelve level tracks conditions based on the normal probability procedure. The dynamic analyses by Runge-Kutta method which are able to analyze the high frequency wheel force spectrum. A dynamic behaviour of KTX due to high speeds until 450km/h developing speed with relative time is analysed and compared the characteristics running over the road and PSC box bridge tracks. Finally, the KTX integrated evaluation method of safety between high speed train and bridge is presented.

  • PDF

디더 운동이 캡슐형 내시경의 마찰계수 감소에 미치는 영향 (Influence of Dither Motion on the Friction Coefficient of a Capsule-type Endoscope)

  • 홍예선;최민준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1068-1073
    • /
    • 2005
  • Development of a locomotive mechanism for the capsule type endoscopes will largely enhance the ability to diagnose disease of digestive organs. In connection with it, most of the researches have focused on an installable locomotive mechanism in the capsule. In this paper, it is introduced that the movement of a capsule type endoscope in digestive organ can be manipulated by magnetic force produced outside human body. Since the magnetic force is provided by permanent magnets, no additional power supply to the capsule is required. Using a robotic manipulator for locating the external magnet, the capsule motion control system can cover the whole human digestive organs. This study is particularly concentrated on dither motion effect to improve the mobility of capsule type endoscope. It was experimentally found out that the friction coefficient between the capsule and digestive organ can be remarkably reduced by superposing yawing or rolling dither motion on the translatory motion. In this paper, the experimental results obtained while the direction, amplitude and frequency of sinusoidal dither motion were changed are reported.

  • PDF

8200호대 전기기관차 보조전원장치 개발품의 신뢰도 기반 수명주기비용 분석 (Life Cycle Cost Analysis of Auxiliary Power Unit Developments for 8200 Series Electric Locomotive Based on Reliability)

  • 이계승;김완일;창윤우;김재문
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1523-1529
    • /
    • 2018
  • Electric vehicles that are currently in operation are being produced domestically. Therefore, there is no great difficulty in receiving or repairing the failed parts or in the overall repair. On the other hand, most of the electric locomotives are manufactured by introducing the parts and technology of foreign vehicle manufacturers. In this paper, conducted a study about life cycle cost analysis of developed auxiliary power unit in 8200 series electric locomotive and suggested cost down method. This confirms the economic benefits of the developed products of the auxiliary power supply compared to the existing products. In addition, a sensitivity analysis of MTBF was conducted to suggest a life cycle cost down method.

Controllable Movement of the Azobenzene Linked Crown Ether Conjugated Liposome

  • Seo, Eun-Seok;Kim, Soo-Hyun;Kim, Jin-Seok;Kim, Byung-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1158-1162
    • /
    • 2005
  • Drug delivery systems have been developed to reduce the side toxicity of drugs by localizing them in the site of action. But it depends on the circulation of the blood and it doesn't have the function of locomotive mechanism of itself for searching for the region of disease. However, this problem could be solved by nanobot which have the locomotive function. So, we mimic the movement of cell that can move in a human body. In this paper, to polymerize the encapsulated actin within the liposome, electroporation technique is employed. In order to optimize polymerization and depolymerization of the liposome, we compare the time of polymerization and depolymerization by concentration of crown ether. we synthesis the liposome which contain azobenzene Linked crown Ether conjugated Actin protein. Azobenze linked crown ether holds the K+ ion by exposure of UV light and this disturbs the actin polymerization. In result, UV light could control the liposome growth. Finally, we could develop the liposome robot and control the growth and degeneration of the liposome by external stimuli such s UV light. The merit of the controlling by UV light doesn't need to inject proteins which induce polymerization and depolymerization of actin protein.

  • PDF

철도 차량 운전원의 소음노출 특성 (Exposure to Noise on Railroad Operators)

  • 이상윤;최상준
    • 한국환경보건학회지
    • /
    • 제34권2호
    • /
    • pp.153-160
    • /
    • 2008
  • Personal noise exposure was assessed in railroad operators working in 40 operation units including the Gyeongbu line, Honam line, and Janghang line between 2004 and 2006. 8-hour TWA were assessed based on the MOL (Ministry of Labor) guideline on noise evaluation, and 17% of these measurements exceeded 85 dBA while 70% were over 80 dBA. When the ACGIH TLV is adopted, 40% of measurements were over TLV (85 dBA). The noise exposure risk of railroad operators was higher for diesel locomotive operation and longer operational distances; in addition, the risk was higher for passenger car operation compared to freight car driving. Given that in Korea, over the past 30 years diesel locomotives have provided most of the railway's motive power and that hearing protective equipment is not likely to be used by workers during operation, railroad operators are at a high risk of noise-induced hearing loss. The result of audiometric test among 568 railroad operators showed that 32.6% of those tested had a hearing threshold shift of more than 40 dB. In conclusion, this study calls for more fundamental measures including noise control countermeasures within the operation areas, development of equipment that generates less noise and adopting limitation on the operation distance for a work shift.

Number of Steps and Time to Accomplish Turning During Timed Up and Go Test in Community-Dwelling Elderlies With and Without Idiopathic Parkinson Disease

  • Choi, Bong-sam;Lim, Woo-taek
    • 한국전문물리치료학회지
    • /
    • 제23권4호
    • /
    • pp.47-54
    • /
    • 2016
  • Background: Losing balance during locomotive actions becomes an increasing threat to both the community-dwelling elderly and elderly with Parkinson disease (PD). Those with PD may be at a high risk of fall due to particular characteristics during the turn. Turning around during locomotive actions may be one of problematic factors causing losing balance. Objects: This study is part of a larger study, which in part aims to identify turning strategies, to compare the strategies in the elderly with and without idiopathic PD aged 51 years and older and to distinguish whether the turning strategies can predict the elderly at risk of falls. Methods: A total of 22 community-dwelling elderlies (10 elderlies with idiopathic PD and 12 healthy elderlies) were investigated for the turning strategies during the timed up and go test. Results: There were some significant differences between the two groups during turning (p<.05). The idiopathic PD group had a tendency of challenging on taking more number of steps, more time to accomplish and staggering more for the turn relative to the control group. Conclusion: Taking more number of steps and more time to turn may be useful for distinguishing the characteristics of PD from that of the healthy elderly in turning strategy.

다중 위상차를 갖는 조합형 캠을 이용한 다족형 이동 메커니즘 (Locomotion Mechanism Using a Combination Cam with Multi-Phases)

  • 김경대;정연구;김병규;박종오
    • 대한기계학회논문집A
    • /
    • 제26권12호
    • /
    • pp.2598-2604
    • /
    • 2002
  • Robots that can move along the narrow and rough tube are very important as the request for the inspection increases. It is necessary for the inspection robots to have a capability to move successfully at even overturned situation and have a simple mechanism to reduce the unexpected failure possibility fer the successful completion of the given mission. Through this paper, the authors propose a novel and simple mechanism using a combination cam device to generate the locomotive motion of multi-legs. This robot uses one DC motor and one combination cam shaft to generate the locomotive motion and can move rough tubes without failure even at the overturned situation. The robot also shows enough fragging force fer the connected line that is very important for a wired inspection robot. Kinematics analysis to design the specification of the robot will be followed and several applications show this robot's potential capabilities.