• Title/Summary/Keyword: Locking plate

Search Result 163, Processing Time 0.023 seconds

Geometrically Nonlinear Analysis of Higher Order Plate Bending Finite Element (고차 판 유한요소의 기하학적 비선형 해석)

  • Shin, Young Shik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.3
    • /
    • pp.1-10
    • /
    • 1988
  • A higher order plate bending finite element using cubic in-plane displacement profiles is proposed for geometrically nonlinear analysis of thin and thick plates. The higher order plate bending element has been derived from the three dimensional plate-like continuum by discretization of the equations of motion by Galerkin weighted residual method, together with enforcing higher order plate assumptions. Total Lagrangian formulation has been used for geometrically nonlinear analysis of plates and consistent linearization by Newton-Raphson method has been performed to solve the nonlinear equations. The element characteristics have been computed by, selective reduced integration technique using Gauss quadrature to avoid shear locking phenomenon in case of extremely thin plates. Several numerical examples were solved with FEAP macro program to demonstrate versatility and accuracy of the present higher order plate bending element.

  • PDF

Development of 4-node Plate Bending Element using Nonconforming Displacement Modes (비적합 변위모드를 이용한 4절점 평판휨요소의 개발)

  • 박용명;최창근
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.179-188
    • /
    • 1997
  • A 4-node element for efficient finite element analysis of plate bending is presented in this paper. This element is formulated based on Mindlin plate theory to take account of shear deformation. To overcome the overestimation of shear stiffness in thin Mindlin plate element, especially in the lower order element, five nonconforming displacement modes are added to the original displacement fields. The proposed nonconforming element does not possess spurious zero-energy mode and does not show shear locking phenomena in very thin plate even for distorted mesh shapes. It was recognized from benchmark numerical tests that the displacement converges to the analytical solutions rapidly and the stress distributions are very smooth. The element also provides good results for the case of high aspect ratio.

  • PDF

Operative Treatment of Fractures of the Midshaft Clavicle using Locking Compression Plate (Locking Compression Plate를 이용한 전위성 쇄골 간부 골절의 수술적 치료)

  • Chung, Nam-Sik;Hong, Ki-Do;Ha, Sung-Sik;Park, Sung-Joon;Kang, Jung-Ho;Sim, Jae-Cheon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.63-68
    • /
    • 2006
  • Purpose: To assess the effectiveness of the Locking compression plate (LCP) after open reduction for the treatment of the displaced clavicular shaft fracture, the clinical and radiologic outcome of the patients who were managed with the LCP for internal fixation after open reduction has been analyzed. Materials and Methods: We reviewed 26 cases with a displaced clavicular shaft fracture treated by internal fixation using Locking compression plate after open reduction between May 2003 and November 2004. The patients were followed up for at least six months period, and final postoperative outcome was evaluated using clinical results based on Kang's criteria, radiologic signs of fusion. Results: All fractures united by an average of 9.3 weeks without delayed union and showed fast recovery of motion fraction and shoulder function. In addition,24 cases without the fractures of proximal humerus recovered to normal range of shoulder notion within 2.9 weeks. Clinically, according to Kang's criteria, the outcome was good or better in 22 patients. The complications included shoulder joint dysfunction in two cases and keloid formation in one case, and no other complications were observed. Conclusion: The internal fixation using LCP for the treatment of displaced clavicular shaft fracture is a safe, reliable method of treatment, with few complications, and offers rapid recovery of shoulder joint function and bone union.

  • PDF

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.

Clinical Comparison of Two Types of Hook Plate in Surgical Treatment of Acromioclavicular Dislocation - AO Hook Plate and Wolter Plate - (견봉 쇄골 관절 탈구의 수술적 치료에서 두 가지 갈고리 금속판의 임상적 비교 - AO Hook Plate와 Wolter Plate -)

  • Choi, Jea-Yeol;Kim, Eugene;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Se-Jin;Lee, Seung-Hee;Lee, Jae-Wook;Choi, Kyu-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • Objective: To evaluate if acromial locking in hook plate is necessary for surgical treatment of acromioclavicular dislocation by compare Wolter plate and AO hook plate. Methods: Seventy one patients who have Rockwood type III to V acromioclavicular joint dislocation treated with AO hook plate and Wolter plate were involved. Among them, 39 patients were treated with Wolter hook plate and 32 patients with AO hook plate. The Constant-Murley score and the range of motion of shoulder joint were measured on postoperative 1st ,$3^{rd}$, $6^{th}$ and $12^{th}$ months, and the radiological complications involving plate and bone were investigated. Results: Constant-Murley score of postoperative one year were $83.2{\pm}6.8$ in AO hook plate group and $85.2{\pm}5.3$ in Wolter plate group without statistical difference (p<0.05). Faster recover of forward elevation and external rotation were examined in Wolter plate group at first and third months after surgery than those of AO hook plate group, but there were no significant difference between after six months or later after surgery. Four cases of loosen or broken screws and one case of pull-out of plate were found in Wolter plate group. Seven cases of subacromial bony erosion and one periprosthetic fracture were found in AO hook plate group. Conclusion: Although clinical outcomes of both two methods were same, no matter if acromial locking system was or not. More radiological complication of plate and bone were found in AO hook plate than that of Wolter plate. However also had disadvantage like larger incision during surgery.

Load Sharing Mechanism Across Graft-Bone Interface in Static Cervical Locking Plate Fixation

  • Han, In-Ho;Kuh, Sung-Uk;Chin, Dong-Kyu;Jin, Byung-Ho;Cho, Yang-Eun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.4
    • /
    • pp.213-218
    • /
    • 2009
  • Objective : This study is a retrospective clinical study over more than 4 years of follow up to understand the mechanism of load sharing across the graft-bone interface in the static locking plate (SLP) fixation compared with non-locking plate (NLP). Methods : Orion locking plates and Top non-locking plates were used for SLP fixation in 29 patients and NLP fixation in 24 patients, respectively. Successful interbody fusion was estimated by dynamic X-ray films. The checking parameters were as follows : screw angle (SA) between upper and lower screw, anterior and posterior height of fusion segment between upper and lower endplate (AH & PH), and upper and lower distance from vertebral endplate to the end of plate (UD & LD). Each follow-up value of AH and PH were compared to initial values. Contributions of upper and lower collapse to whole segment collapse were estimated. Results : Successful intervertebral bone fusion rate was 100% in the SLP group and 92% in the NLP group. The follow-up mean value of SA in SLP group was not significantly changed compared with initial value, but follow-up mean value of SA in NLP group decreased more than those in SLP group (p=0.0067). Statistical analysis did not show a significant difference in the change in AH and PH between SLP and NLP groups (p>0.05). Follow-up AH of NLP group showed more collapse than PH of same group (p=0.04). The upper portion of the vertebral body collapsed more than the lower portion in the SLP fixation (p=0.00058). Conclusion : The fused segments with SLP had successful bone fusion without change in initial screw angle, which was not observed in NLP fixation. It suggests that there was enough load sharing across bone-graft interface in SLP fixation.

Metastatic Pathologic Fractures in Lower Extremities Treated with the Locking Plate (잠김 금속판을 이용한 하지의 전이성 병적 골절에 대한 치료)

  • Seo, Chang-Young;Jung, Sung-Taek
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.2
    • /
    • pp.80-86
    • /
    • 2010
  • Purpose: The skeleton is commonly affected by metastatic cancer. The purpose of this study was to evaluate the results of treating metastatic pathologic fractures in lower extremities using locking plates. Materials and Methods: Between 2004 and 2010, we evaluated 12 patients (13 cases) of metastatic pathologic fractures in lower extremities, treated with the locking plate. Mean patient age was 62.2 years (range, 50-81 years), the locations of the fractures were; proximal femur in 2 cases, femoral mid-shaft in 3, distal femur in 3, proximal tibia in 4, and distal tibia in 1 case. The interval to wheelchair ambulation, pain relief and complications were evaluated. Additionally, we assessed operation time and postoperative blood loss. Results: Mean time from operation to wheelchair ambulation was 3.2 days (range, 1-6 days). Mean VAS scores improved from a preoperative score of 8.1 points (range, 7-9 points) to a score of 2.7 points (range, 2-4 points) at 1 week postoperatively. No early complications associated with surgery were encountered. Mean operation time was 88.4 minutes (range, 70-105 minutes), and mean postoperative blood loss was 246.5 ml (range, 130-320 ml). Conclusion: Internal fixation of metastatic pathologic fractures using a locking plate in the lower extremity can be an effective treatment option in the meta- or diaphyseal area of long bones with massive bony destruction or poor bone stock by offering early ambulation, pain relief and low postoperative complications.

Coracoclavicular Ligament Suture Augmentation with Anatomical Locking Plate Fixation for Distal Clavicle Fracture

  • Lim, Tae Kang;Shon, Min Soo;Ryu, Hyung Gon;Seo, Jae Sung;Park, Jae Hyun;Ko, Young;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.175-180
    • /
    • 2014
  • Background: For Neer type IIB fracture of distal clavicle with coracoclavicular ligament injury, various surgical treatments have been used in literatures. However, there was no consensus on the optimal treatment. The aim of this study is to report the clinical and radiological results of open reduction and internal fixation of unstable distal clavicle fracture and suture augmentation of disrupted coracoclavicular ligament. Methods: A prospective study was performed in 23 patients with Neer type IIB distal clavicle fracture in Seoul Medical Center, Eulji Hospital, and National Medical Center. Firstly, suture anchors are inserted in the base of coracoid process and preliminary reduction was achieved by tie-off of three suture limbs around the clavicle. Then, the final fixation was completed with anatomical locking plate. Bony union and the distance between coracoclavicular ligaments were evaluated. Clinical results and complications including stiffness and secondary procedures were evaluated. Results: Bony union was achieved in all cases except one (22 of 23). At mean 14.9 months, no significant difference in the mean coracoclavicular distance was observed compared to uninjured shoulder ($8.2{\pm}7.9mm$ versus $7.3{\pm}3.4mm$, p=0.14). Pain visual analogue scale, American Shoulder and Elbow Surgeons score, Constant score, and Disabilities of the Arm, Shoulder and Hand score were 0.5, 83.4, 78.5, and 6.2, respectively. Revision surgery was performed in one case of nonunion. Four patients who complained of skin irritation underwent implant removal. Conclusions: In cases of an unstable distal clavicle fracture with coracoclavicular ligament disruption, satisfactory clinical results were obtained by locking plate fixation and coracoclavicular ligament suture augmentation concurrently.

Minimally Invasive Percutaneous Plate Osteosynthesis via a Deltoid-splitting Approach with Strut Allograft for the Treatment of Displaced 3- or 4-part Proximal Humeral Fractures

  • Noh, Young-Min;Kim, Dong Ryul;Kim, Chul-Hong;Lee, Seung Yup
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.4
    • /
    • pp.220-226
    • /
    • 2018
  • Background: This study introduces a surgical technique with good clinical outcome useful in the treatment of osteoporotic displaced 3- or 4-part proximal humeral fractures. Methods: From May 2014 to February 2016, 16 patients with displaced 3- or 4-part proximal humeral fractures were treated by application of a locking plate with an endosteal strut allograft via a deltoid splitting approach with a minimum follow-up of 12 months. The allograft was inserted through a fractured gap of the greater tuberosity to support the humeral head and then fixed by a locking plate with meticulous soft tissue dissection to protect the axillary nerve. Surgical outcomes were evaluated by the American Shoulder and Elbow Surgeons (ASES) and visual analogue scale (VAS) scores, radiological imaging, and clinical examination. Fixation failure on radiographs was defined as a >$5^{\circ}$ loss of neck shaft angle (NSA) compared to that on an immediate postoperative radiograph. Avascular necrosis (AVN) of the humeral head was also evaluated. Results: In all cases, complete union was achieved. The ASES and VAS scores were improved to $85.4{\pm}2.1$ and $3.2{\pm}1.3$, respectively. Twelve patients (75.0%) had greater than a $5^{\circ}$ change in NSA; the average NSA change was $3.8^{\circ}$. Five patients (31.3%) had unsatisfactory ranges of motion exhibiting a <$100^{\circ}$ active forward flexion. No axillary nerve injuries or AVN were observed at the last follow-up. One patient was converted to reverse total arthroplasty due to severe pain and functional deficit. Conclusions: Minimally invasive fixation via a locking compression plate and an endosteal fibula strut allograft in Neer classification 3-or 4-part fractures with severe osteoporosis in elderly patients can achieve good clinical results.