• Title/Summary/Keyword: Locking plate

Search Result 164, Processing Time 0.027 seconds

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.

A co-rotational 8-node assumed strain element for large displacement elasto-plastic analysis of plates and shells

  • Kim, K.D.
    • Structural Engineering and Mechanics
    • /
    • v.15 no.2
    • /
    • pp.199-223
    • /
    • 2003
  • The formulation of a non-linear shear deformable shell element is presented for the solution of stability problems of stiffened plates and shells. The formulation of the geometrical stiffness presented here is exactly defined on the midsurface and is efficient for analyzing stability problems of thick plates and shells by incorporating bending moment and transverse shear resultant force. As a result of the explicit integration of the tangent stiffness matrix, this formulation is computationally very efficient in incremental nonlinear analysis. The element is free of both membrane and shear locking behaviour by using the assumed strain method such that the element performs very well in the thin shells. By using six degrees of freedom per node, the present element can model stiffened plate and shell structures. The formulation includes large displacement effects and elasto-plastic material behaviour. The material is assumed to be isotropic and elasto-plastic obeying Von Mises's yield condition and its associated flow rules. The results showed good agreement with references and computational efficiency.

Femoral Periprosthetic Fractures after Total Knee Arthroplasty: New Surgically Oriented Classification with a Review of Current Treatments

  • Rhee, Seung Joon;Cho, Jae Young;Choi, Yoon Young;Sawaguchi, Takeshi;Suh, Jeung Tak
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.284-292
    • /
    • 2018
  • Purpose: As the number of total knee arthroplasties (TKAs) increases, the incidence of femoral periprosthetic fractures after TKA is also increasing. This review aimed to suggest a new surgically oriented classification system for femoral periprosthetic fractures. Methods: We investigated the classifications, and current treatment trends for femoral periprosthetic fractures after TKA by means of a thorough review of the relevant literature. Results: Numerous studies reported good results of surgical treatment with modern fixatives including locking compression plates and retrograde intramedullary nails. However, few classifications of femoral periprosthetic fractures reflect the recent developments in surgical treatment. Conclusions: We recommend that surgical management be considered the first-line treatment for femoral periprosthetic fractures after TKA. Our new classification will help in deciding the surgical treatment option for femoral periprosthetic fractures after TKA.

Adult Proximal Humeral Locking Plate Is a Good Alternative Option in the Treatment of Adolescent Subtrochanteric Femur Fractures: A Case Series and Literature Review

  • Ceyhun Caglar;Serhat Akcaalan;Merve Bozer;Mustafa Akkaya
    • Hip & pelvis
    • /
    • v.34 no.4
    • /
    • pp.245-254
    • /
    • 2022
  • Purpose: Management of pediatric subtrochanteric femur fractures (SFFs) is difficult. The aim of this study was to evaluate the outcomes of adolescent SFFs treated with adult proximal humeral locking plates (PHLPs). Materials and Methods: A retrospective analysis of 18 adolescents (11 male, 7 female) with a diagnosis of SFF who underwent internal fixation with a PHLP was conducted. Data regarding injury mechanism, fracture pattern, and time to union were recorded for all patients. In addition, a clinical and functional evaluation of patients was performed using the Harris hip score (HHS), Iowa hip score (IHS), modified Merle d'Aubigne-Postel score (MMAPS), Flynn criteria, and hip range of motion (ROM). Results: The mean age of the patients was 12.72±2.05 years (range, 10-16 years). Radiological observation was performed for evaluation of five different injury mechanisms and different fracture patterns in patients. The mean postoperative HHS was 92.27±5.61, the mean IHS was 90.88±6.46, and the mean MMAPS was 17.22±0.94. According to the Flynn criteria, excellent results were achieved in 14 cases and satisfactory results were obtained in four cases. Measurements of the patients' mean hip ROM values were as follows: 17.77±3.52° in extension, 115.27±6.74° in flexion, 43.05±3.48° in abduction, 27.50±4.28° in adduction, 42.22±4.60° in internal rotation, and 42.22±3.91° in external rotation. Conclusion: Surgery performed on adolescent patients using an adult PHLP showed good, safe results. Therefore, it should be considered as an alternative option.

Simulation of Woody Leaf Netted Venation Based on Optimization Technique (최적화기법에 의한 나뭇잎 그물맥 시뮬레이션)

  • Chen, Lei;Li, Weizheng;Jang, Gang Won;Baek, Tae Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.323-329
    • /
    • 2013
  • This study attempts to simulate the structure of a woody leaf netted venation system by using topology optimization techniques. Based on finite element method (FEM) analysis of an incompressible fluid, a topology optimal design is applied to those woody leaf netted venation models. To solve the transverse shear locking problem of a thin plate caused by the Mindlin-Reissner plate model where a leaf netted venation is assumed to be a thin plate, a P1-nonconforming element and selective reduced integration are employed. Topology optimal design is applied to multiple physical domains. Combined with the Darcy-Stokes flow problems and extended to the optimal design of fluid channels, the multiple physical models of the flow system are analyzed and venation patterns of leafs are simulated. The calculated optimal shapes are compared with the natural shapes of woody leaf venation patterns. This interdisciplinary approach may improve our understanding of the leaf venation system.

Fatigue Characterization of Glass/Polypropylene Composite Bone Plates Locked with an Artificial Tibia under Moisture Environment (인조골에 체결된 유리섬유/폴리프로필렌 복합재료 고정판의 수분 환경 피로 특성)

  • Han, Min-Gu;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.26 no.5
    • /
    • pp.328-333
    • /
    • 2013
  • In this study, bone plate made of glass/polypropylene composite material which was applied to an artificial bone was tested to check the service ability under fatigue loading. To check serviceability of composite bone plates fatigue test was carried out considering changes in the moisture absorption rate, locking position of screws and loading condition. Test results showed that all the tested specimens had the fatigue life more than one million cycles which was much higher fatigue life than the expected value of 650,000 cycles. Screw position was not critical impact on the deformation of the fracture site. In this paper, the mechanical performance of the glass/polypropylene composite was verified by fatigue test under various water absorption conditions, and this result may give useful information on the design of composite bone plate.

Ultrasonographic Diagnosis of Extensor Tenosynovitis Caused by Dorsal Screw Prominence after Volar Plate Fixation of Distal Radius Fracture: Case Report (원위 요골 골절의 수장측 금속판 고정술 후 발생한 신전건 활막염에 대한 초음파를 이용한 진단: 증례 보고)

  • Lim, Tae Kang;Kim, Sang Yeol;Kang, Hong Je;Hah, Dae Ho
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.6 no.2
    • /
    • pp.60-64
    • /
    • 2013
  • After volar locking plating of distal radius fracture, complications arising from unrecognized dorsally prominent screws penetrating the extensor compartments are increasingly reported. However, standard radiography and fluoroscopy may not adequately visualize screw lengths, because of complex shape of dorsal cortex of the distal radius. We presented case of ultrasonography diagnosis of extensor tenosynovitis caused by dorsal screw prominence after volar plate fixation of distal radius fracture.

  • PDF

Clinical and Radiological Outcomes of Acute Acromioclavicular Joint Dislocation: Comparison of Hook Plate Fixation with Single Tight Rope Technique

  • Lee, Sung Hyun;Kim, Jeong Woo;Kook, Seng Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.153-161
    • /
    • 2017
  • Background: This study was conducted to compare the clinical and radiological outcomes of the locking hook plate fixation (HP) technique and the single tight rope (TR) technique applied for acute high-grade acromioclavicular (AC) joint separations. Methods: Between 2009 and 2014, 135 consecutive patients with acute AC joint separation Rockwood types III, IV, and V were subjected to surgical reconstruction. One hundred fourteen patients (84.4%) were available for retrospective evaluation. Of them, 62 and 52 were treated using the single TR group and clavicular HP group techniques, respectively. The visual analogue scale, Constant, American Shoulder and Elbow Surgeons (ASES), and Taft scores were used for clinical assessment. Postoperative shoulder range of motion was also assessed. An anteroposterior radiograph of the coracoclavicular distance (CCD) was obtained to evaluate the radiographic signs of recurrence. Results: The TR group patients had better Constant, ASES, and Taft scores than the HP group patients. The loss of reduction in terms of the CCD did not differ between groups. Subacromial osteolysis was observed in 34.6% of the cases in the HP group. However, there were no significant differences in the clinical outcomes between the patients with and without osteolysis in the HP group. Subcoracoid osteolysis, drill tunnel widening, and metal displacement were observed in 3.2%, 22.6%, and 4.8% of the cases in the TR group, respectively. Conclusions: The single TR technique was relatively more effective at treating acute high-grade AC joint injuries than the HP fixation technique (level of evidence: therapeutic; retrospective comparative study, Level III).

Morphometric Variations in the Volar Aspect of the Distal Radius

  • Kwon, Bong Cheol;Lee, Joon Kyu;Lee, Suk Yoon;Hwang, Jae Yeun;Seo, Jang-Hyeon
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.462-467
    • /
    • 2018
  • Background: Significant discrepancy exists between anatomical plate designs and the anatomy of the native distal radius, which may be attributable to considerable morphometric variations in the volar aspect of the distal radius. We aimed to evaluate the degree of variability in the morphometry of the distal radius and identify factors associated with this variability. Methods: We measured the volar surface angle (VSA) of the intermediate and lateral columns and the volar surface width (VSW) in the distal radius from three-dimensional computed tomography scans acquired from 81 cadaveric forearms. These morphometric parameters were compared between the lateral and intermediate columns, between males and females, and between Koreans and Caucasians. Caucasian morphometric data were obtained and pooled from the previous studies. The coefficient of variation was used to assess the variability of the parameters and Cohen's d to estimate the effect size of the difference between groups. Results: The average VSA of the lateral column was $22^{\circ}{\pm}6^{\circ}$, and that of the intermediate column was $29^{\circ}{\pm}8^{\circ}$ in Koreans (p < 0.001). The variability was high for both VSAs. The VSA of the intermediate column was significantly larger in males than in females (p < 0.001) and in Caucasians than in Koreans (p < 0.001). The average VSW of distal radius was $30{\pm}3mm$ at the watershed line, and it became narrower proximally. The VSW was significantly larger in males than in females (p < 0.001) and in Koreans than in Caucasians (p < 0.001). The effect sizes of the difference for the VSA and VSW between sexes, races and columns were medium to large. Conclusions: Considerable variability exists in the morphometry of the volar distal radius, with sex, race, and column as contributing factors. These results suggest that surgeons should carefully choose an anatomical volar locking plate with appropriate angulation characteristics for each patient to achieve patient-specific alignment of the distal radius.

The Treatment of Humerus Shaft Simple Fracture by MIPO Technique (상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료)

  • Ko, Sang-Hun;Lee, Sun-Ho;Cho, Bum-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the clinical and radiological outcomes of treatment of humerus shaft simple fracture by minimally invasive percutaneous osteosynthesis (MIPO) technique using locking compression plate (LCP). Materials and Methods: Six patients who were operated for humerus shaft simple fracture from August 2010 to May 2011 were enrolled for this study. We checked the cause of injury and the accompanying injuries and evaluated the operation time, the clinical and radiological period of union, postoperative range of motion of the shoulder and elbow joint, pain, activities in daily living, radiologic alignment, and other complications. Results: The clinical period of bone union was 7.2 weeks on average, and the radiologic period of bone union was 8 weeks on average. Follow-up period was more than 12 months in all cases. The angulation through postoperative alignment was 2.8 degrees in AP view and 2 degrees in lateral view. The postoperative range of motion was 167 degrees in forward flexion, 50 degrees in external rotation, and thoracic vertebra 12 level in internal rotation. The average value of visual analogue scale (VAS) was 1.2 and that of KSS was 91.3. The American Shoulder and Elbow Surgeons' score (ASES) was 26.5 and the UCLA score was 31.5. Conclusion: MIPO technique for the humerus shaft simple fracture showed good functional and radiological outcomes and may be considered as one of the treatment options for humerus shaft simple fracture.