• Title/Summary/Keyword: Locking Part

Search Result 50, Processing Time 0.02 seconds

Design of Low Voltage 1.8V, Wide Range 50∼500MHz Delay Locked Loop for DDR SDRAM (DDR SDRAM을 위한 저전압 1.8V 광대역 50∼500MHz Delay Locked Loop의 설계)

  • Koo, In-Jae;Chung, Kang-Min
    • The KIPS Transactions:PartA
    • /
    • v.10A no.3
    • /
    • pp.247-254
    • /
    • 2003
  • This paper describes a Delay Locked Loop (DLL) with low supply voltage and wide lock range for Synchronous DRAM which employs Double Data Rate (DDR) technique for faster data transmission. To obtain high resolution and fast lock-on time, a new type of phase detector is designed. The new counter and lock indicator structure are suggested based on the Dual-clock dual-data Flip Flop (DCDD FF). The DCDD FF reduces the size of counter and lock indicator by about 70%. The delay line is composed of coarse and fine units. By the use of fast phase detector, the coarse delay line can detect minute phase difference of 0.2 nsec and below. Aided further by the new type of 3-step vernier fine delay line, this DLL circuit achieves unprecedented timing resolution of 25psec. This DLL spans wide locking range from 500MHz to 500MHz and generates high-speed clocks with fast lock-on time of less than 5 clocks. When designed using 0.25 um CMOS technology with 1.8V supply voltage, the circuit consumes 32mA at 500MHz locked condition. This circuit can be also used for other applications as well, such as synchronization of high frequency communication systems.

Database Construction for Design of the Components Software by Using an Incremental Update Propagation

  • Oh, Am-Suk;Kwon, Oh-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.4
    • /
    • pp.583-593
    • /
    • 2003
  • Engineering design applications require the support of long transactions in cooperative environments. The problem of the existing copy/update/merge approaches is that the partial effects of a committed transaction may be not part of the merged version. This paper introduces a new cooperative transaction model, which allows updates to be progressively notified or propagated into other transactions accessing the same object. To support incremental update propagation and notification, we use the term dynamic dependency to define the intertransaction dependency relationships among all the objects checked out from the public database. Consistency in multiple copies of the same object is achieved by a two-phase delta-merge protocol. Our model provides a synchronization of cooperative updates performed in several workspaces without using locking mechanisms.

  • PDF

A Lubrication Analysis between the Piston and Cylinder in Hydraulic Piston Pumps Part 1: The effect of piston shape (유압 피스톤 펌프의 피스톤과 실린더 사이의 윤활해석 (제1보:피스톤 형상에 의한 영향))

  • 박태조;전병수
    • Tribology and Lubricants
    • /
    • v.14 no.1
    • /
    • pp.64-69
    • /
    • 1998
  • A numerical analysis is carried out to study the effect of piston shape on the lubrication characteristics between the cylinder and piston in hydraulic piston pumps. The results showed that the shape of piston affect significantly the pressure distribution in the clearance, the lateral force acting on the piston and leakage flow through the clearance. Partially tapered piston is more effective than any other piston shapes because it reduces the possibility of hydraulic locking and improves the volumetric efficiency of the pump.

Strength Analysis for Compressed Coil Spring in the Gage - Adjustable Wheelset System (궤간 가변 윤축의 압축스프링에 대한 강도해석)

  • Kim, Chul-Su;Ahn, Seung-Ho;Chung, Kwang-Woo;Jang, Seung-Ho;Jang, Kook-Jin;Kim, Jung-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1012-1017
    • /
    • 2007
  • To reduce the cost and the time of transport in Eurasian railroad networks such as TKR(Trans-Korea Railway), TCR(Trans-China Railway) and TSR(Trans-Siberia Railway) owing to the problem of different track gauges (narrow/standard/broad gauge), it is important to develop the gauge - adjustable wheelset system to adapt easily to these gauges. Moreover, this system accomplishes periodically a conversion operation from the gauge variable segment between different gauge. Gauge adjustable compression coil spring during conversion process accomplishes repetitively a central role for operation mechanism between flange and locking part. Therefore, to assure the safety of the gauge-adjustment wheelset system, it is necessary to stress analysis of the optimized spring in the system. In this study, it was performed to optimal design of the spring for stress analysis by using the genetic algorithm.

  • PDF

A Study on Safety Evaluation of Wheel Using Roller Rig Tester (주행시험기를 이용한 차륜의 안전성 평가에 관한 연구)

  • Ham, Young Sam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.7
    • /
    • pp.591-595
    • /
    • 2015
  • The roller rig tester for safety performance evaluation of wheel derailment is a test facility which can give the test load condition to the test wheel, similar to the actual dynamic condition in actual running condition. This study describes the evaluation result on the durability of the resilient wheel equipped with the ring damper and the damping material, and installed in the half part of a full scaled bogie in combination with the primary spring when it rotates under the dynamic condition. The evaluation result on durability of resilient wheel after load test of 2 million cycles shows that the safety of wheel is not affected by the applied load in visual inspection and nondestructive test, however, in the bolt used for fastening the ring damper to the wheel the loosening was found. Accordingly the use of self-locking nut and washer is recommended.

DPLL System Development using 100GHz Band Gunn VCO (100GHz 대역 Gunn VCO를 이용한 DPLL 시스템 개발연구)

  • Lee, Chang-Hoon;Kim, K.D.;Chung, M.H.;Kim, H.R.
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.210-215
    • /
    • 2006
  • In this paper, we develop the PLL system of the local oscillator system using Gunn oscillator VCO for millimeter wave band receiving system. The local oscillator system consists of the $86{\sim}115GHz$ Gunn. diode oscillator part, the RF processing part including the diplexer and the harmonic mixer, and the DPLL system including Gunn modulator and controller. Based on this configuration, we verify the frequency and power stability of the developed local oscillator system. We developed system which applied to DPLL technique instead of the existing analog PLL method to accomplish this purpose. The developed system for this purpose is tested the frequency and power stability for a long time to confirm performance. Since we confirmed this system that had frequency characteristic of within ${\pm}10Hz$, very fine output drift power characteristic of $0.2{\sim}0.3dBm$ and about 200MHz locking range, it verified suitable for cosmic radio receiving system through the test result.

Tribological Failure Examples Involving Hydraulic Unit, Sensor, Computer of Anti-lock Brake System in Passenger Cars (승용차 ABS의 하이드로릭 유닛, 센서, 컴퓨터에 관련된 트라이볼로지적인 고장사례 고찰)

  • Lee, IlKwon;Han, JaeOh;Lee, JongHo;Lee, YoungSuk;Kim, ChooHa
    • Tribology and Lubricants
    • /
    • v.30 no.3
    • /
    • pp.183-188
    • /
    • 2014
  • In this paper, we present our analysis of tribological failure examples for an anti-lock brake system(ABS) in a car. The study range of this paper is to improve the quality of ABS system by analyzing with sensor, computer, actuator and oil lines. In the first example, the brake leak from hydraulic supply line in a caliper on the rear left side of the ABS hydraulic modulator. This produces the sponge phenomenon, where the car does not brake even when the driver operates the brake pedal. The hydraulic unit operating ABS is actuator that play role regulating drive condition according with the oil pressure supplied with wheel of a car. In the second example, the service man does not completely tighten the fixed bolt after repairing the car. This causes the ABS warning lamp to light up as the ABS wheel speed sensor cannot detect whether the ABS has been activated. In the third example, the ABS electronic control unit is separated from the soldered part of the inner circuit board. Consequently, the ABS fails in control because the ABS motor pump receives no-signal for the hydraulic unit. The wheel speed sensor has to large durability because of giving signal of acting condition to computer by detected the acceleration and deceleration of wheel of a car. In the fourth example, the ABS warning lamp lights up of when cracks propagate in the circuit board soldering part. The circuit of this computer is very important part for input and output the operating signal of system. Such failures can aggravate the durability of the ABS. Thus, the ABS needs to be optimized to eliminate malfunction phenomenon.

Development of Three-Dimensional Fracture Strain Surface in Average Stress Triaxiaility and Average Normalized Lode Parameter Domain for Arctic High Tensile Steel: Part II Formulation of Fracture Strain Surface (극한지용 고장력강의 평균 응력 삼축비 및 평균 정규 로드 파라메터를 고려한 3차원 파단 변형률 평면 개발: 제2부 파단 변형률 평면의 정식화)

  • Chong, Joonmo;Park, Sung-Ju;Kim, Younghun
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.454-462
    • /
    • 2015
  • An extended study was conducted on the fracture criterion by Choung et al. (2011; 2012) and Choung and Nam (2013), and the results are presented in two parts. The theoretical background of the fracture and the results of new experimental studies were reported in Part I, and three-dimensional fracture surface formulations and verifications are reported in Part II. How the corrected true stress can be processed from the extrapolated true stress is first introduced. Numerical simulations using the corrected true stress were conducted for pure shear, shear-tension, and pure compression tests. The numerical results perfectly coincided with test results, except for the pure shear simulations, where volume locking appeared to prevent a load reduction. The average stress triaxialities, average normalized lode parameters, and equivalent plastic strain at fracture initiation were extracted from numerical simulations to formulate a new three-dimensional fracture strain surface. A series of extra tests with asymmetric notch specimens was performed to check the validity of the newly developed fracture strain surface. Then, a new user-subroutine was developed to calculate and transfer the two fracture parameters to commercial finite element code. Simulation results based on the user-subroutine were in good agreement with the test results.

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Design & Implementation of DRM System for End-to-end Content Protection (End-to-end 콘텐츠 보호를 위한 DRM 시스템 설계 및 구현)

  • Jeong Yeon-Jeong;Yoon Ki-Song
    • The KIPS Transactions:PartC
    • /
    • v.13C no.1 s.104
    • /
    • pp.35-44
    • /
    • 2006
  • Current technologies on digital rights management (DRM) have focused on security and encryption as a means of solving the issue of unauthorized copying, that is, locking the content and limiting its distribution to only purchasers. But, illegal content copy should be protected not only from purchasers but also from other principals such as media distributors and content providers. In this paper, we designed and implemented end-to-end digital lights management system that can cover a content protection on the overall value-chains of content distribution. Proposed system provides content protection and secure management of digital rights in creator, provider, and distributor like in purchaser. Accordingly it can provide an environment protecting each principal's digital rights and prohibiting illegal usage of content.