• 제목/요약/키워드: Locking

검색결과 993건 처리시간 0.028초

A Fast-Locking Fractional-N PLL with Multiple Charge Pumps and Capacitance Scaling Scheme (Capacitance Scaling 구조와 여러 개의 전하 펌프를 이용한 고속의 ${\Sigma}{\Delta}$ Fractional-N PLL)

  • Kwon, Tae-Ha
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제43권10호
    • /
    • pp.90-96
    • /
    • 2006
  • A novel ${\Sigma}{\Delta}$ fractional-N PLL architecture for fast locking and fractional spur suppressing is proposed based on the capacitance scaling scheme. It changes the effective capacitance of loop filter (LF) by increasing and decreasing current to the capacitor via different paths with multiple charge pumps. The effective capacitance of loop filter (LF) can be scaled up/down depending on operating status while keeping LF capacitors small enough to be integrated into a single PLL chip. Fractional spurs suppressing have been achieved by reducing the magnitude of charge pump current when the PLL is in-lock without degrading fast locking characteristic. It has been simulated by HSPICE in a CMOS $0.35{\mu}m$ process, and shows flat locking time is less than $8{\mu}s$ with the small size of LF capacitors, 200pF and 17pF, and $2.8k{\Omega}$ resistor.

The Outcomes of Proximal Humerus Fractures with Medial Metaphyseal Disruption Treated with Fibular Allograft Augmentation and Locking Plate

  • Kim, Doo Sup;Yoon, Yeo Seung;Kang, Sang Kyu;Jin, Han Bin;Lee, Dong Woo
    • Clinics in Shoulder and Elbow
    • /
    • 제20권2호
    • /
    • pp.90-94
    • /
    • 2017
  • Background: Proximal humerus fracture is considered to be the third most common fracture for patients aged 65 years or older. Conservative treatment has been known to treat most of humerus fracture. However, fractures with severe displacement or dislocation may require surgical treatment. Intramedullary fibular allograft with a locking plate is frequently used in patients accompanying medial metaphyseal disruption. In this study, author intends to evaluate clinical and imaging results based on patients who underwent surgical treatment using fibular allograft with a locking plate. Methods: This study is conducted prospectively at Wonju Severance Christian Hospital, targeting patients who previously underwent surgical treatment using open reduction and intramedullary fibular allograft with a locking plate between 2011 and 2015. A total of 26 patients were evaluated on the following: postoperational clinical assessment measuring Constant score, American Shoulder and Elbow Society (ASES) score, and the Disabilities of the Arm, Shoulder and Hand (DASH) score. Postoperational imaging assessments are evaluated via measuring the neck-shaft angle. The study subject were Neer classification type 3, 4 proximal humerus fracture cases with disrupted medial hinge and having cortical comminution in the region of the surgical neck. Results: The average period of progression was 22.5 months, and the average age of patients was 72.6 years. At the final follow-up, the average Constant, average ASES, and average DASH scores were 80.1, 78.5, and 20.6 respectively. The average neck-shaft angle was $127.5^{\circ}$. Conclusions: In conclusion, fibular allograft augmentation with a locking plate showed satisfying results in both clinical and imaging studies.

Design and Implementation of Real-Time Static Locking Protocol for Main-memory Database Systems (주기억장치 데이타베이스 시스템을 위한 실시간 정적 로킹 기법의 설계 및 구현)

  • Kim, Young-Chul;You, Han-Yang;Kim, Jin-Ho;Kim, June;Seo, Sang-Ku
    • Journal of KIISE:Databases
    • /
    • 제29권6호
    • /
    • pp.464-476
    • /
    • 2002
  • Main-memory database systems which reside entire databases in main memory are suitable for high-performance real-time transaction processing. If two-phase locking(2PL) as concurrency control protocol is used for the transactions accessing main-memory databases, however, the possibility of lock conflict will be low but lock operations become relatively big overhead in total transaction processing time. In this paper, We designed a real-time static locking(RT-SL) protocol which minimizes lock operation overhead and reflects the priority of transactions and we implemented it on a main-memory real-time database system, Mr.RT. We also evaluate and compare its performance with the existing real-time locking protocols based on 2PL such as 2PL-PI and 2PL-HP. The extensive experiments reveal that our RT-SL outperforms the existing ones in most cases.

The Development Process of Vehicle Roof Carrier using One Side Release System (측면 단동 릴리즈 시스템을 이용한 자동차용 루프 캐리어 개발 프로세스)

  • Jang, Dong-Hwan;Ko, Byung-Doo;Lee, In-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제27권5호
    • /
    • pp.56-62
    • /
    • 2010
  • This paper presents the development process of roof carrier assembly using a one side release system for a vehicle. An RV(Recreational Vehicle) or SUV(Sports Utility Vehicle) has a roof carrier system on an upper surface of a roof panel for loading large or long size baggage. Such a roof carrier system is comprised of a roof rack longitudinally mounted on a roof panel and cross bar perpendicularly installed in the horizontal direction. Several locking mechanisms used in most vehicle roof carrier systems are composed with both side releasable locking ones. The obvious drawback to this arrangement is that when the user desires to reposition the cross bar, first one of the locking members must be unlocked and then the user must walk around to the opposite side of the vehicle to unlock the other member. In this paper, we proposed a newly locking mechanism, which allows a user simultaneously place both locking members of the roof carrier in locked and unlocked positions. In order to estimate design compatibility, structural and modal analysis is performed. Furthermore, a prototype based on the proposed design has been made, and then durability test carried out. From the simulation and experimental results, the proposed roof carrier system is proved effective and safe.

Design and Performance Test of Locking Curved-Nut (풀림방지 Curved-Nut 설계 및 성능 시험)

  • Cha, Min Cheol;Kang, Ho Sung;Kim, Do Yeop;Lee, Suk Yong;Jeong, Hui Jong;Lee, Eung Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제41권3호
    • /
    • pp.199-204
    • /
    • 2017
  • Many types of locking nut are commercializing in the various industries where has heavy vibration. Because nut's loosing causes a serious accident. But the most locking nuts are too expensive as the complicate manufacturing process. In this study, we design the new type of locking nut, "Curved-Nut" that is relatively simple making process. We study a relation between the elastic energy and the nut loosing mechanism. So it is analysed, the elastic energy of Curved-Nut comparing with the locking test. The Curved-Nut was manufactured on the commercial nut using a milling tool with horizontal cutting, one or two time under the nut. As the result, the more elastic energy the more prevent the loosing of the nut. We verified the performance of the loosing nut using the vibration testing equipment (NAS3350).

Isogeometric method based in-plane and out-of-plane free vibration analysis for Timoshenko curved beams

  • Liu, Hongliang;Zhu, Xuefeng;Yang, Dixiong
    • Structural Engineering and Mechanics
    • /
    • 제59권3호
    • /
    • pp.503-526
    • /
    • 2016
  • In-plane and out-of-plane free vibration analysis of Timoshenko curved beams is addressed based on the isogeometric method, and an effective scheme to avoid numerical locking in both of the two patterns is proposed in this paper. The isogeometric computational model takes into account the effects of shear deformation, rotary inertia and axis extensibility of curved beams, and is applicable for uniform circular beams, and more complicated variable curvature and cross-section beams as illustrated by numerical examples. Meanwhile, it is shown that, the $C^{p-1}$-continuous NURBS elements remarkably have higher accuracy than the finite elements with the same number of degrees of freedom. Nevertheless, for in-plane or out-of-plane vibration analysis of Timoshenko curved beams, the NURBS-based isogeometric method also exhibits locking effect to some extent. To eliminate numerical locking, the selective reduced one-point integration and $\bar{B}$ projection element based on stiffness ratio is devised to achieve locking free analysis for in-plane and out-of-plane models, respectively. The suggested integral schemes for moderately slender models obtain accurate results in both dominated and non-dominated regions of locking effect. Moreover, this strategy is effective for beam structures with different slenderness. Finally, the influence factors of structural parameters of curved beams on their natural frequency are scrutinized.

Reduced Minimization Theory in Skew Beam Element (공간곡선보요소에서의 감차최소화 이론)

  • Moon, Won-joo;Kim, Yong-woo;Min, Oak-key;Lee, Kang-won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제20권12호
    • /
    • pp.3792-3803
    • /
    • 1996
  • Since the skew beam element has two curvatures which are a curvature and a torsion, spatial behavior of curved beam which cannot be included in one plane can be anlayzed by emploting the skew beam element. The $C^{0}$-continuous skew beam element shows the stiffness locking phenomenon when full integration is employed. The locking phenomenpn is characterized by two typical phenomena ; one is the much smaller displacement thant the exact one and theother is the undelation phenomenon is stress distribution. In this paper, we examine how unmatched coefficient in the constrained energy brings about the locking by Reduced Minimization theory. We perform the numerical ones. These comparisons show that uniformly full integration(UFI), which employs full integration for the constrained energy, entails the locking phenomenon. But the use of uniformly reduced integration(URI) of selectively reduced integration(SRI), which employs reduced integration for constrained energy, does not produce the significant errors of displacements of the undulation phenomenon in stress distribution since they do not entails the locking, Additionally, the error due to the approximated parameters for describing the geometry of skew beam is examined.d.

Comparison of F Calcaneal Plate and Locking Calcaneal Plate Fixation Using an Lateral Extensile Approach to Intra-articular Calcaneal Fractures (종골의 관절 내 골절에서 외측 광범위 도달법을 이용한 F형 금속판 고정술과 잠김 금속판 고정술의 비교)

  • Lee, Yun-Tae;Oh, Hyun-Cheol;Yoon, Han-Kook;Jang, Jae-Won;Jang, Ki-Jun
    • Journal of Korean Foot and Ankle Society
    • /
    • 제16권3호
    • /
    • pp.175-180
    • /
    • 2012
  • Purpose: To evaluate the radiological and clinical results after open reduction and internal fixation with calcaneal F plate and locking calcaneal plate using lateral extensile approach in the treatment of intra-articular calcaneal fracture Materials and Methods: This study included 34 cases of 33 patients followed up for at least 6 months postoperatively. F plate was applied in 18 cases (Group 1), locking plate was used in 16 cases (Group 2) and compared radiological and clinical results between two groups. Results: Radiollogically, the mean Bohler angle was improved from $5.5^{\circ}$ preoperatively to $20.1^{\circ}$ postoperatively and $18.8^{\circ}$ at the last follow up in group 1 and $8.6^{\circ}$ preoperatively, $21.4^{\circ}$ postoperatively and $20.3^{\circ}$ at last follow up in group 2. Bone union was observed in all cases and 4 cases of screw loosening were noted in Group 1 with extended fracture to anterior process. At the last follow up, both groups showed clinical results in American orthopedic foot and ankle society ankle hindfoot score, 76(77 in Sanders type II and 75 in type III) in group 1 and 72(73 in type II and 70 in type III) in group 2. Conclusion: F plate and locking plate showed firm fixation and satisfactory clinical results in the treatment of intra-articular calcaneal fracture. We suggest applying locking plate in cases with extended fracture to anterior process, considering screw loosenings in those who were treated with F plate fixation.

Two-Way Donation Locking for Transaction Management in Database Systems (데이터베이스 시스템에서 거래관리를 위한 두단계기부잠금규약)

  • Rhee, Hae-Kyung;Kim, Ung-Mo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • 제37권2호
    • /
    • pp.1-10
    • /
    • 2000
  • Traditional syntax-oriented serializability notions ate considered to be not enough to handle in particular various types of transaction in terms of duration of execution. To deal with this situation, altruistic locking has attempted to reduce delay effect associated with lock release moment by use of the idea of donation. An improved form of altruism has also been deployed in extended altruistic locking in a way that scope of data to be early released is enlarged to include even data initially not intended to be donated. In this paper, we first of all investigated limitations inherent in both altruistic schemes from the perspective of alleviating starvation occasions for transactions in particular of short-lived nature. The idea of two-way donation locking(2DL) has then been experimented to see the effect of more than single donation in client-server database systems. Simulation experiments shows that 2DL outperforms the conventional two-phase locking in terms of the degree of concurrency and average transaction waiting time under the circumstances that the size of long-transaction is in between 5 and 9.

  • PDF