• Title/Summary/Keyword: Local fire

Search Result 353, Processing Time 0.033 seconds

Development and Application of CFT without Fire Protection using High Performance Steel and Concrete

  • Hong, Seok-Beom;Kim, Woo-Jae;Park, Hee-Gon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.272-281
    • /
    • 2013
  • Concrete filled tube (CFT) columns, which consist of a steel tube filled with concrete, combine the benefits of the two materials. The steel tube provides a confining pressure to the concrete, while the local buckling of steel plate can be prevented by the concrete core. CFT columns also have a high fire resistance due to the heat storage effect of concrete under fire. For this reason, it is possible to develop CFT columns without fire protection measures. CFT columns without fire protection have many advantages, including quality control, cost reduction, better space efficiency and a shorter construction period. Due to these advantages, studies on the development of CFT columns without fire protection measures have been performed. However, CFT columns lose their bearing capacity under fire because the steel tube is exposed to the outside. As a result, the structure is collapsed, causing significant damage. In this research, we made a CFT column using high strength concrete (100 MPa) and high strength steel (800 MPa). We use steel fiber and nylon fiber with concrete to provide fire resistance. We perform the fresh concrete experiment and investigate the fire resistance of the CFT column (${\Box}400{\times}400{\times}15{\times}3000mm$) under loading. To investigate the effect of steel fiber on increasing fire resistance, we compare the fire resistance time according to the steel fiber. Through the test, it was found that the CFT specimen with steel fiber had better fire resistance performance than other cases.

Method of Determining Future Facility Location with Maintaining Present Accessibility

  • Takahagi, Wataru;Sumitani, Yasushi;Takahashi, Hirotaka;Omae, Yuto;Sakai, Kazuki
    • Industrial Engineering and Management Systems
    • /
    • v.15 no.3
    • /
    • pp.197-205
    • /
    • 2016
  • The public services closely related to the daily lives of the Japanese people, such as firefighting, police or primary school education, are largely financed by the local governments. As the population as a whole in Japan declines, the population in local regions are forecasted to experience particularly rapid decline in the future, and it is inevitable to reduce the cost of public services provided by the local governments to keep their financial basis sustainable. In order to provide public services to the people properly and fairly, the local governments own and utilize their public facilities, such as fire stations, police stations or primary schools. On the other hand, we have to secure the accessibility, which is the condition of accessing a facility easily in a whole local city including the high population density area and low population density area. In this paper, we propose a method of determining the number of future facilities and its facility locations in which we maintain the present accessibility. In our proposed method, we determine them comparing the accessibility measurement calculated by facility location model using the present and future population. We adopted k-centdian model as the facility location model, which can secure the accessibility in a whole local city determining the weights of both areas. We applied our proposed method to fire station in Iwaki city, Japan. The results suggested that 7 facilities would be reduced in 2064, after 50 years from 2014. Additionally, we confirmed that the future facility location had secured accessibility in both high and low population density area.

An Experimental Study on the Operating Characteristics with HVAC Type of Shopping Center in Underground Passage (지하도상가의 HVAC 구성방식에 따른 운전특성 연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.76-81
    • /
    • 2007
  • The shopping center in underground passage increased for efficient space utilization in urban area. This study describes operation characteristics of all air type and hybrid type with local ventilation and fan coil unit fixed to ceiling. In order to compare energy saving, thermal environment and installation space, etc., integrated simulator with heat production and indoor distribution system is designed and constructed. Energy saving of the hybrid system is calculated as over 30% compared to conventional all air type. And also the results showed that humidity decreased about 6%, also indoor thermal distribution is improved as temperature variation of around $1^{\circ}C$.

  • PDF

Collapse Initiation and Mechanisms for a Generic Multi-storey Steel Frame Subjected to Uniform and Travelling Fires

  • Rackauskaite, Egle;Kotsovinos, Panagiotis;Lange, David;Rein, Guillermo
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.265-283
    • /
    • 2021
  • To ensure that fire induced collapse of a building is prevented it is important to understand the sequence of events that can lead to this event. In this paper, the initiation of collapse mechanisms of generic a multi-storey steel frame subjected to vertical and horizontal travelling fires are analysed computationally by tracking the formation of plastic hinges in the frame and generation of fire induced loads. Both uniform and travelling fires are considered. In total 58 different cases are analysed using finite element software LS-DYNA. For the frame examined with a simple and generic structural arrangement and higher applied fire protection to the columns, the results indicate that collapse mechanisms for singe floor and multiple floor fires can be each split into two main groups. For single floor fires (taking place in the upper floors of the frame (Group S1)), collapse is initiated by the pull-in of external columns when heated beams in end bays go into catenary action. For single floor fires occurring on the lower floors(Group S2), failure is initiated (i.e. ultimate strain of the material is exceeded) after the local beam collapse. Failure in both groups for single floor fires is governed by the generation of high loads due to restrained thermal expansion and the loss of material strength. For multiple floor fires with a low number of fire floors (1 to 3) - Group M1, failure is dominated by the loss of material strength and collapse is mainly initiated by the pull-in of external columns. For the cases with a larger number of fire floors (5 to 10) - Group M2, failure is dominated by thermal expansion and collapse is mainly initiated by swaying of the frame to the side of fire origin. The results show that for the investigated frame initiation of collapse mechanisms are affected by the fire type, the number of fire floors, and the location of the fire floor. The findings of this study could be of use to designers of buildings when developing fire protection strategies for steel framed buildings where the potential for a multifloor fire exists.

Progressive Collapse of Steel High-Rise Buildings Exposed to Fire: Current State of Research

  • Jiang, Jian;Li, Guo-Qiang
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.375-387
    • /
    • 2018
  • This paper presents a review on progressive collapse mechanism of steel framed buildings exposed to fire. The influence of load ratios, strength of structural members (beam, column, slab, connection), fire scenarios, bracing systems, fire protections on the collapse mode and collapse time of structures is comprehensively reviewed. It is found that the key influencing factors include load ratio, fire scenario, bracing layout and fire protection. The application of strong beams, high load ratios, multi-compartment fires will lead to global downward collapse which is undesirable. The catenary action in beams and tensile membrane action in slabs contribute to the enhancement of structural collapse resistance, leading to a ductile collapse mechanism. It is recommended to increase the reinforcement ratio in the sagging and hogging region of slabs to not only enhance the tensile membrane action in the slab, but to prevent the failure of beam-to-column connections. It is also found that a frame may collapse in the cooling phase of compartment fires or under travelling fires. This is because that the steel members may experience maximum temperatures and maximum displacements under these two fire scenarios. An edge bay fire is more prone to induce the collapse of structures than a central bay fire. The progressive collapse of buildings can be effectively prevented by using bracing systems and fire protections. A combination of horizontal and vertical bracing systems as well as increasing the strength and stiffness of bracing members is recommended to enhance the collapse resistance. A protected frame dose not collapse immediately after the local failure but experiences a relatively long withstanding period of at least 60 mins. It is suggested to use three-dimensional models for accurate predictions of whether, when and how a structure collapses under various fire scenarios.

Correlation between the Apartment Resident Community and Housing Satisfaction (아파트 거주자의 커뮤니티와 주거만족도 간의 인과관계)

  • Kim, Myung-Hee;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.3
    • /
    • pp.61-68
    • /
    • 2020
  • This study aims to determine the correlation between the apartment resident community and housing satisfaction and suggest which factors can contribute to improving the local community's housing environment and satisfaction by means of the local inhabitants and apartment residents participating in co-managing the community. The study results are as follows. Firstly, the apartment resident community had a positive effect on housing satisfaction but the effects were insignificant. This revealed that residents' interest in communicating with the resident community was low due to various organizations such as the women's association, election committee, and autonomous society being used as means to pursue personal gain rather than the development of the entire apartment. Secondly, the vitalization of the apartment resident community had a positive effect on housing satisfaction. The analysis results showed that the higher the level of unity and volunteering activities of residents, the more improved the resident vitalization programs are being managed, and the higher the level of resident participation, the higher the housing satisfaction. Lastly, this study suggests the supplementation and upgrading of apartment community facilities into complex community facilities as a means to unify the residents and vitalize the resident community. To vitalize the resident community and strengthen the community spirit, the residents will need to voluntarily create a community hub by forming community-tailored associations and programs through connections with local governments and businesses.

Linking Spatial Characteristics of Forest Structure and Burn Severity (산림 공간구조 특성과 산불 연소강도와의 관계에 관한 연구)

  • Lee, Sang-Woo;Lim, Joo-Hoon;Won, Myoung-Su;Lee, Joo-Mee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.5
    • /
    • pp.28-41
    • /
    • 2009
  • Because fire has significant impacts on fauna and flora in forest ecosystems, as well as socioeconomic influences to local community, it has been an important field of study for decades. One of the most common ways to reduce fire risk is to enhance fire-resilience of forest through fuel treatments including thinning and prescribed burning. Since fuel treatment can't be practiced over all forested areas, appropriate and effective strategies are needed. The present study aims to look at the relationship between spatial characteristics of forest structure measured with landscape pattern metrics and burn severity to provide guidelines for effective fuel treatments. Samchuck fire was selected for the study, and 232 grids covering the study areas were generated, and the grid size was 1km. The burn severity is measured with dNBR derived from satellite imagery, and spatial characteristics of forest structure were measured using FRAGSTATS for both landscape and class levels for each 1km grid. The results of this study strongly indicated that heterogeneity in composition and configuration of forests may significantly reduce burn severity. By enhancing heterogeneity of forests, fuel treatments for fire-resilience forest could be more effective.

A Study on Fireproofing Application by Fire Magnitude (화재규모에 따른 화학공장의 내화구조 적용에 대한 연구)

  • Lee, Dong Hyeok;Yoo, Byung Tae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.46-52
    • /
    • 2018
  • Interest in fire prevention/fighting has been increased by large fire. It is important to install/manage the detector, alarm, firefighting facility, evacuation route and so on to minimize the damage from fire. Chemical plant is generally constructed by steel structure. So fireproofing is significantly required to chemical plant because steel structure should endure during fire. Currently, fireproofing should be applied up to 6m from ground by local regulation. But chemical plant can handle the large amount of flammable materials or only non-flammable materials. Required of fireproofing height by fire magnitude is studied in this thesis.

A Study on the Multiple Disaster Administration's Problem and Improvement (대형 재해관리의 문제점과 개선방안)

  • Kim, Hak-Soo;Koh, Jae-Moon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.7 no.1
    • /
    • pp.179-198
    • /
    • 2003
  • If see disaster administration system of our country, start in terms of is coping by countermeasure after four immediately after disaster occurrence many problems blessing with a sons by tribe and so on of link nature between formation, disaster administration complete charge utensil's absence, disaster charge manpower and budget be indicated and join. If examine improvement way accordingly, is as following ; Necessity of synthetic disaster administration system, Fire fighting formation's independence guarantee, Integration of fire fighting connection similarity business, Disaster administration's permanent establishment complete charge utensil's necessity, Disaster administration midautumn complete charge utensil at a metropolitan autonomous fire fighting system reorganization, Role division of labor between center and local government, Disaster administration professional human strength positivity, Disaster administration information system construction practical use, Equipment and improvement of budget state, Education public information for safety culture consciousness fixing, Internationalization of fire fighting business, globalization propulsion, Structure, member of rescue confrontation system and efficiency. Fire fighting environment is changing greatly, and fire fighting must become center to correspond to do confrontation that do one thing troble when produce disaster.

  • PDF

A Study on the Improvement Method of Forest Fire Caused by Waste Incineration at the Farming Residential Area (농촌 주거지역 쓰레기소각으로 인한 산불화재 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • Currently the forest area is 6,370,000 hectare (ha) which occupies 63.7% in Korea. The forest has good functions such as production of forest products, conservation of national land, prevention of disasters, etc. However constructing houses near the forest area make bad situation like illegal waste incineration by resident. So research subject is forest fire caused by waste incineration place including facility. And this study was conducted about statistical analysis and research analysis of the 100 waste incineration places including facilities at the country town. Statistical analysis shows that March is 27% which percentage is the highest number of forest fire in 10 years' average. The number of forest fire caused by waste incineration is 45 which is the third highest number in the fire statistic. The distance between waste incineration place including facility and forest area is 30m, 40m and 50m. That 40m (36%) is the most common distance from forest area. The types of waste incineration are ground (62%), the temporary facility made with oil drum can (35%) and other made with steel sheet, concrete, etc. The result of this study is that government and local government must conduct the improvement measure to reduce illegal incineration such as waste pickup area made with rain and wind proof type installed near residence, expenses for waste treatment, enlightenment and training, etc. Also considering their age and income are needed for realistic improvement.