• Title/Summary/Keyword: Local fire

Search Result 354, Processing Time 0.029 seconds

A Study on the Improvement Method of Forest Fire Caused by Waste Incineration at the Farming Residential Area (농촌 주거지역 쓰레기소각으로 인한 산불화재 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.9-15
    • /
    • 2016
  • Currently the forest area is 6,370,000 hectare (ha) which occupies 63.7% in Korea. The forest has good functions such as production of forest products, conservation of national land, prevention of disasters, etc. However constructing houses near the forest area make bad situation like illegal waste incineration by resident. So research subject is forest fire caused by waste incineration place including facility. And this study was conducted about statistical analysis and research analysis of the 100 waste incineration places including facilities at the country town. Statistical analysis shows that March is 27% which percentage is the highest number of forest fire in 10 years' average. The number of forest fire caused by waste incineration is 45 which is the third highest number in the fire statistic. The distance between waste incineration place including facility and forest area is 30m, 40m and 50m. That 40m (36%) is the most common distance from forest area. The types of waste incineration are ground (62%), the temporary facility made with oil drum can (35%) and other made with steel sheet, concrete, etc. The result of this study is that government and local government must conduct the improvement measure to reduce illegal incineration such as waste pickup area made with rain and wind proof type installed near residence, expenses for waste treatment, enlightenment and training, etc. Also considering their age and income are needed for realistic improvement.

Sub-Surface Station Fire Evacuation Research and Best Practice

  • Dowens, Trevor
    • International Journal of Railway
    • /
    • v.2 no.1
    • /
    • pp.18-21
    • /
    • 2009
  • The basis of modem risk-based safety management is to focus on what might happen and ensure it is designed out of the system by robust hazard identification and risk analysis. However, in the real world things go wrong and it is essential to be prepared for the worst so that the response can minimise harm and loss of property and damage to the environment. Whilst some hazard mitigation measures are aimed at preventing incidents, others are venting escalation. The results of the tests concluded that the most effective means by the control room, both with and without, local station staff assistance using directive public address announcements and CCTV surveillance.

  • PDF

Vulnerability Analysis on Fire Service Zone using Map Overlay Method in GIS (GIS 기반 중첩기법을 이용한 소방서비스 취약지역 분석)

  • Lee, Seul-Ji;Lee, Ji-Yeong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.91-100
    • /
    • 2011
  • Fire stations should be located in optimal location to act quickly in case of emergency and minimize damages as a public facility that protects life and property of local residents. Siting fire stations without regard for the accessibility and occurrence factors of an accident may provide fire service unequally. Therefore service analysis is necessary to reduce the blind spot of disaster and safety and to offer equal fire-service at this time. Especially fire stations can service more efficiently than before by reducing a more likely vulnerable area. This study suggests methods of mapping index of value that represents vulnerability of the occurrence of an accident and extracting service zone map of fire stations, as an initial research for offering efficient fire service. Geographical distribution mismatch between service zone map and vulnerability map is figured out and vulnerable area for fire service is defined by using map overlay method.

Climate Change over Korea and Its Relation to the Forest Fire Occurrence (기후 변화에 따른 한반도 산불 발생의 시공간적 변화 경향)

  • Sung, Mi-Kyung;Lim, Gyu-Ho;Choi, Eun-Ho;Lee, Yun-Young;Won, Myoung-Soo;Koo, Kyo-Sang
    • Atmosphere
    • /
    • v.20 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This study analyzes the climate change in Korea and its impact on the occurrence of forest fire events. The forest fire occurrences in Korea tend to concentrate around large cities. In addition, the spatial distribution of the forest fire occurrence seems to agree with local climate conditions. Though the occurrence of the forest fire shows strong interannual variation, it also exhibits a positive trend. Because the forest fire frequently occurs during early spring, we examined long term climate variability in Korea for the early spring seasons. The climate change in Korea generally has brought warmer, drier, and less precipitable conditions during the early spring. The changes of the atmospheric conditions provide favorable condition for the forest fire. The climate changes in Korea also depict distinct spatial variability according to the atmospheric variables. We compared the regional trend of the fire occurrence with the climate trends. The results show the sharpest growing in the forest fire occurrence over southwest of Korea. This study suggests that the decrease in the precipitation day might affect the sharp increasement of the forest fire occurrence in the southwest of Korea.

Thermal-Structure Interaction Parallel Fire Analysis for Steel-Concrete Composite Structures under Bridge Exposed to Fire Loading (화재에 노출된 교량하부 강합성 구조물에 대한 열-구조 연성 병렬화재해석)

  • Yun, Sung-Hwan;Gil, Heungbae;Lee, Ilkeun;Kim, Wooseok;Park, Taehyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.4
    • /
    • pp.283-292
    • /
    • 2013
  • The objective of this research is to evaluate of global and local damage for steel-concrete composite structures under highway bridge exposed to fire loading. To enhance the accuracy and efficiency of the numerical analysis, the proposed transient nonlinear thermal structure interaction(TSI) parallel fire analysis method is implemented in ANSYS. To validate the TSI parallel fire analysis method, a comparison is made with the standard fire test results. The proposed TSI parallel fire analysis method is applied to fire damage analysis and performance evaluation for Buchen highway bridge. The result of analysis, temperature of low flange and web are exceed the critical temperature. The deflection and deformation state show good agreement with the fire accident of buchen highway bridge.

A Case Study on Local-Based Community Recovery Program in Disaster Affected Areas (재난피해지역 내 지역사회기반 공동체 회복 프로그램 사례 연구)

  • Lee, Young Uk;Nam, Dong Yup;Jeong, Hye Min;Park, Sang Hyun;Lee, Ji Hyang
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.106-114
    • /
    • 2020
  • The two major trends that have emerged in recent years in relation to disaster recovery and recovery are 'regional infrastructure', 'regional leadership' and 'community recovery'. In the former case, it is to avoid disaster recovery and recovery by using external personnel and resources, and to maximize the resources in the area under the initiative of the residents of the affected area. And through this process, it is to prepare a new growth engine for disaster-affected areas. In addition, the latter expands disaster recovery targets to the general population living in affected areas and is not limited to victims. Through this, we can expect to recover the 'community' beyond the individual's recovery. In the Ansan of Gyeonggi-do, where many families of 'Sewolho' live, and in the Heunghae-eup of Pohang, Gyeongbuk-do, where the damage was severe, projects are underway to restore communities. And In these areas local activists and civic groups are actively utilized to efforts are being made to increase efficiency. Nevertheless, in the case of the community recovery program being promoted in Korea, there are limitations that it can be promoted only on the basis of special laws and that participation of various actors is necessary. This study intends to propose the limitations of current projects and ways to solve them by analyzing domestic and foreign cases related to the community recovery program for disaster-affected communities using local resources. we suggest two way. One is the relaxation of the national dependence of the community recovery program, and the other is to expand the area of disaster relief through.

An Experimental Study on the Temperature Distribution of Square CFT Columns According to the Types of Fire Protection (내화피복 종류에 따른 각형 CFT기둥의 온도분포에 관한 실험적 연구)

  • Kim, Hae-Soo;Lee, Chy-Hyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.6
    • /
    • pp.523-532
    • /
    • 2010
  • Concrete-filled square steel tube (CFT) columns have inherently high fire resistance and load-bearing capacity. Nevertheless, it is sometimes necessary to improve their fire resistance using external fire protection. This paper presents the experimental results of the temperature distribution of CFT columns with fire protection. A fire load test was carried out by exposing small-scale specimens to heat in an electric furnace that was especially built for testing loaded columns. The temperature distribution of CFT columns under constant axial loads was determined, as were its significant parameters, such as the types of fire protection and thickness, the thickness of the square CFT, and the fire duration times. The results of this study showed the temperature distribution of each specimen of the electric furnace and the temperature distribution properties of concrete and steel. In addition, the axial displacement and local buckling behavior of CFT columns based on temperature changes was observed.

Regional Optimization of Forest Fire Danger Index (FFDI) and its Application to 2022 North Korea Wildfires (산불위험지수 지역최적화를 통한 2022년 북한산불 사례분석)

  • Youn, Youjeong;Kim, Seoyeon;Choi, Soyeon;Park, Ganghyun;Kang, Jonggu;Kim, Geunah;Kwon, Chunguen;Seo, Kyungwon;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1847-1859
    • /
    • 2022
  • Wildfires in North Korea can have a directly or indirectly affect South Korea if they go south to the Demilitarized Zone. Therefore, this study calculates the regional optimized Forest Fire Danger Index (FFDI) based on Local Data Assessment and Prediction System (LDAPS) weather data to obtain forest fire risk in North Korea, and applied it to the cases in Goseong-gun and Cheorwon-gun, North Korea in April 2022. As a result, the suitability was confirmed as the FFDI at the time of ignition corresponded to the risk class Extreme and Severe sections, respectively. In addition, a qualitative comparison of the risk map and the soil moisture map before and after the wildfire, the correlation was grasped. A new forest fire risk index that combines drought factors such as soil moisture, Standardized Precipitation Index (SPI), and Normalized Difference Water Index (NDWI) will be needed in the future.

A Study on the Emergency Medical Service Demand and Fire Service Force (구급서비스 수요와 소방력에 관한 연구)

  • Kim, Jin-Dong;Shin, Sang-Yol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4485-4491
    • /
    • 2013
  • This study was to investigate emergency medical service demands, fire service force of local governments, and relationship between these two factors for developing effective prehospital emergency medical services. For this, this study was measured the ratio of the number of patients transported and residents, ambulances and residents, patients transported and ambulance workers of 16 local governments. And then examined hypotheses. Data were collected from 2000 year to 2010 year. This study results indicated that average number of patients transported are significant differences not only between metropolitan district and general district, but also between capital area and non-capital area. And this study indicated that the fire service force are significant differences not only between metropolitan district and general district, but also between capital area and non-capital area. Also, the numbers of patients transported per ambulance, and the numbers of patients transported per ambulance worker were significant by regional groups. The number of patients transported per ambulance was a significant difference between the first half and the second half, but there was not a significant different the number of patients transported between the first half and the second half.

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.