Pressure Loss and Enhancement of Heat Transfer in an Annulus Filled with Aluminum Foam

  • Noh, Joo-Suk;Han, Young-Hee;Lee, Kye-Bock;Lee, Chung-Gu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2007
  • An experimental investigation was carried out for 4 different types of the aluminum foam heat sinks which were inserted into the annulus. The purpose of this study is to examine the feasibility of a heat sink with high performance forced convective water cooling in the annulus. The local wall temperature distribution, inlet and outlet pressures and temperatures, and heat transfer coefficients were measured for heat flux of 13.6, 18.9, 25.1, 31.4 $kW/m^2$ and Reynolds number ranged from 120 to 9,000. Experimental results show that the departure from the Darcy's law is evident from the pressure loss and the friction factor is much higher while the significant enhancement in Nusselt number is obtained, and average Nusselt number of aluminum foam with high pore density is much higher than that of aluminum foam with low pore density. Correlations for the friction factor is proposed and used for design of thermal applications.

Natural Convection Heat Transfer from a Horizontal Annulus with Spacers (격판을 가진 수평환상공간에서의 자연대류 열전달)

  • 이범철;정한식;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.153-160
    • /
    • 1989
  • A numerical and experimental study has been performed on natural convection heat transfer from a horizontal annulus with spacers. The mode of heat transfer in the annulus is changed from conduction to convection at Ra = 10$^{3}$. By increasing wall conductivity, mean Nusselt number is apparently increased at $K_{w}$/K$_{f}$ .leg. 48, but at /K$_{w}$/K$_{f}$ > 48, slightly increased for no spacers, and decreased for vertical spacers and horizontal spacers. The mean Nusselt number can be represented in an exponential function of Grashof number at all conditions. The characterics of natural convection heat transfer show similiarity for no spacers and vertical spacers but show difference for horizontal spacers. The presence of the horizontal spacers increased the convective heat transfer by an average 6 percent over that for the no forced cooling to outer cylinder. The maximum local Nusselt number appears at .theta. = 150.deg. in a conducting tube and .theta. = 30.deg. in an outer cylinder for vertical spacers, and appears at .theta. = 180.deg. in a conducting tube and .theta. = 0.deg. in an outer cylinder for horizontal spacers.spacers.

Numerical Analysis for the Unsteady Laminar Flow and Heat Transfer Around a Circular Cylinder (원주 주위의 비정상 층류유동과 열전달에 대한 수치해석)

  • 조석호;남청도;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.64-72
    • /
    • 1991
  • The unsteady, two-dimensional laminar flow and heat transfer of an incompressible, constant-property fluid flowing around a circular cylinder are numerically analyzed. The Navier-Strokes equation and the energy equation are solved by the finite difference method. The range of the Reynolds number is 10 to 100 and the Prandtl number considered is 0.7. The contours of the flow pattern, equi-vorticity line and isotherm pattern around a circular cylinder are shown. Also, numerical solutions of the surface vorticity, pressure coefficient, drag coefficient, local Nusselt number and mean Nusselt number are obtained. The numerical results for the final time fo calculation are compared with the other available experimental and theoretical results for the steady state and are found to be in good agreement with them.

  • PDF

Numerical Study of Natural Convection in a Rectangular Enclosure with Cooling Strip (냉각부(冷却部)를 갖는 사각형(四角形) 밀폐공간내(密閉空間內)의 자연대류(自然對流)에 관(關)한 수치해석(數値解析))

  • Lee, Cheong-Ouk;Seo, Jeong-Yun;Kim, Chong-Bo
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.54-61
    • /
    • 1986
  • The influence on natural convection was studied by solving the partial differential equations within a rectangular enclosure which have a cooling strip at the right side wall of the space, a isothermally heated bottom plate and adiabatic two other walls. Computation was carried out for the range of Grashof number from $5*10^3$ to $2.5*10^5$ with Plandtl number of 0.73. The results have been obtained in cases of four aspect ratios and various strip sizes. Temperature and Stream function distributions have been plotted using explicit finite difference method in two dimensional, laminar flow, and also mean Nusselt number and Local Nusselt number have been obtained.

  • PDF

Numerical Study of Laminar Flow and Heat Transfer in Curved Pipe Flow (곡관에서의 층류 유동 및 열전달에 관한 수치해석 연구)

  • Kang, Changwoo;Yang, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.941-951
    • /
    • 2013
  • A three dimensional numerical simulation of laminar flow and heat transfer in fully developed curved pipe flow has been performed to study the effects of Dean number and pipe curvature on the flow and temperature fields under the thermal boundary condition of axially uniform wall heat flux. The Reynolds number under consideration ranges from 100 to 4000, and the Prandtl number is 0.71. The curvature ratios are 0.01, 0.025, 0.05 and 0.1. The axial velocity and temperature profiles and the local Nusselt number obtained from the present study are in good agreement with the previous numerical and experimental results currently available. To show the effects of pipe curvature on the flow and heat transfer, the resistance coefficients and heat transfer coefficients are computed and compared with the results of the previous theoretical and experimental studies. The averaged Nusselt number is correlated with Dean and Prandtl numbers. Furthermore, the critical Reynolds number for transition to turbulent flow is observed to depend upon the curvature ratio.

Heat Transfer Measurement by a Round Jet Impinging on a Rib-Roughened Concave Surface (표면조도를 가지는 오목한 면에 충돌하는 원형제트에 의한 열전달 측정)

  • Lee, Dae Hee;Won, Se Youl;Lee, Joon Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.734-743
    • /
    • 1999
  • The local Nusselt numbers have been measured for a round turbulent jet impinging on the concave surface with and without rib. Liquid crystal/transient method was used to determine the Nusselt number distributions along the surface. The temperature on the surface was measured using liquid crystal and a digital color image processing system. The experiments were made for the jet Reynolds number (Re) 23,000, the dimensionless nozzle-to-surface distance (L/d) from 4 to 10, the dimensionless surface curvature (d/D) 0.056, and the rib type (height ($d_1$) 0.2 cm, pitch (p) from 1.2 to 3.2 cm). It was founded that only when $L/d{\geq}6$, the average Nusselt numbers on the concave surface with rib are higher than those without rib, mainly due to an increase in the turbulent intensity caused by the effect of rib attached to the wall surface. It was realized that the rib attached to the concave surface may no longer enhance the heat transfer rate or even lowers it depending on the rib type and flow conditions. In addition, the results by the steady-state method using the gold-film Intrex were in good agreement with those by the transient shroud method.

Heat Transfer from Single and Arrays of Impinging Water Jets(I)-Single Water Jet- (단일수분류 및 수분류군에 의한 열전달(I)-단일수분류-)

  • Eom, Gi-Chan;Lee, Jong-Su;Yu, Ji-O
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1105-1114
    • /
    • 1997
  • The heat transfer characteristics of free surface water jet impinging normally against a flat uniform heat flux surface were investigated. This deals with the effect of three nozzle configurations (Cone type, Reverse cone type, Vertical circular type) on the local and the average heat transfer. Heat transfer measurements were made for water jet issuing from a nozzle of which exit diameter 8 mm. The experimental conditions investigated are Reynolds number range of 27000 ~ 70000( $V_{O}$=3 ~ 8 m/s), nozzle-to-target plate distances H/D=2 ~ 10, and radial distance from the stagnation point r/D ~ = 0 ~ 7.42. For all jet velocities of H/D=2, the local Nusselt number decreased monotonically with increasing radial distance. However, for H/D from 4 to 10, and for the jet velocity $V_{O}$.geq.7 m/s for Cone type nozzle and $V_{O}$.geq.6 m/s for the other type nozzles, the Nusselt number distributions exhibited secondary peaks at r/D=3 ~ 3.5. For Reverse cone type nozzle and Vertical circular nozzle, the maximum stagnation point heat transfer and the maximum average heat transfer occurs at H/D=8. But for the Cone type nozzle, the maximum stagnation and average heat transfer occurs at H/D=10, 4, respectively. From the optimum nozzle-to-target plate distance, the stagnation and the average heat transfer reveal the following ranking: Reverse cone type nozzle, Vertical circular type nozzle, Cone type nozzle.ozzle.

Non-uniform wall temperature effect of the flow and heat transfer of a hot circular air jet impinging on a circular cylinder (비균일 벽면 온도가 원형 실린더에 충돌하는 고온 제트 유동 및 열전달에 미치는 영향)

  • Hong, Gi-Hyeok;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.882-890
    • /
    • 1997
  • A buoyant jet flow impinging on a circular cylinder is investigated including heat conduction through the cylinder. Temperature and flow fields are obtained by an iterative method, and the effects of the non-uniform wall temperature on the flow and heat transfer are analyzed. Effects of three-dimensionality and the traversing of the jet are also included. Nusselt number over the cylinder surface for the conjugate case is relatively small as compared with the constant wall temperature case due to the small temperature gradient. As the conductivity of the cylinder becomes lower, Nusselt number decreases due to the reduced temperature gradient. Increasing jet traversing speed causes the surface temperature of the cylinder to decrease, which increases local Nusselt number over the surface.

Heat transfer and flow characteristics of a circular jet impinging on a convex curved surface (볼록한 반구면에 충돌하는 원형제트의 열전달 및 유동특성)

  • Lee, Dae-Hui;Jeong, Yeong-Seok;Im, Gyeong-Bin;Kim, Dae-Seong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.579-588
    • /
    • 1997
  • The heat transfer and flow measurements from a convex curved surface to a circular impinging jet have been made. The flow at the nozzle exit has a fully developed velocity profile. The jet Reynolds number (Re) ranges from 11,000 to 50,000, the dimensionless nozzle-to-surface distance (L/d) from 2 to 10, and the dimensionless surface curvature (d/D) from 0.034 to 0.089. The results show that the stagnation point Nusselt number (N $u_{st}$ ) increases with increasing value of d/D. The maximum Nusselt number at the stagnation point occurs at L/d .ident. 6 to 8 for all Re's and d/D's tested. For larger L/d, N $u_{st}$ dependency on Re is stronger due to an increase of turbulence in the approaching jet as a result of the more active exchange of momentum with a surrounding air. The local Nusselt number decreases monotonically from its maximum value at the stagnation point. However, for L/d=2 and Re=23,000, and for L/d.leq.4 and Re=50,000, the stream wise Nusselt number distributions exhibit secondary maxima at r/d .ident. 2.2. The formation of the secondary maxima is attributed to an increase in the turbulence level resulting from the transition from a laminar to a turbulent boundary layer.ndary layer.

Study on the Experiment and Numerical Computation of Forced Convection Heat Transfer around Circular Cylinder in a Rectangular Duct (사각덕트 내에서 원형 실린더 주위의 강제대류 열전달에 대한 실험과 수치계산에 관한 연구)

  • 윤영환;김경환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.490-498
    • /
    • 2004
  • This paper measures the forced convective heat transfer from heated cylinder to air flow in a rectangular duct at Re$_{D}$ =2,337, 4,589, 6,621 and 7,944 through experiments. And the heat transfer is computed by 3-D numerical computation in which various turbulent models are applied. It is shown through the comparison of experimental and computed data that numerical computation with standard k-$\varepsilon$ model predicts the experimental data most accurately. Furthermore, the correlation from the computed heat transfer is almost similar to that from the experiment when Re$_{D}$ is greater than 4,589. In addition, the correlation of McAdams is the closest to that from experimental data among various correlations from literature in the range of Reynolds number.ber.