• 제목/요약/키워드: Local Melting

검색결과 80건 처리시간 0.023초

An Experimental Study on the Defrosting Behavior of a Fin-Tube Heat Exchanger

  • Lee, Kwan-Soo;Jhee, Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.101-111
    • /
    • 1999
  • The effect of various conditions of frosting and defrosting on the defrosting behavior of a fin-tube heat exchanger has been examined experimentally. An electric heater is used for defrosting in a fin-tube heat exchanger. There are several local maxima in the water draining rate. The amount of residual water on the heat exchanger after completion of defrosting is kept constant due to surface tension on the heat exchanger. Without considering degradation of the thermal performance due to the frosting, the defrosting efficiency is improved with increasing amount of frost irrespective of the frosting condition. The defrosting behavior is affected by frosting density as well as frost accumulation, both of which vary with the experimental operating conditions. The heat loss to the surrounding air decreases, and melting and defrosting efficiencies show high values with decreasing heat input.

  • PDF

DNA computing using a difference of melting temperature among DNA fragments

  • 이지연;신수용;장병탁;박태현
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2002년도 생물공학의 동향 (X)
    • /
    • pp.539-542
    • /
    • 2002
  • We propose new encoding method for numerical data in DNA using temperature gradient. To represent numerical values in DNA sequences, we introduce melting temperature. Since DNA strands representing smaller values have a lower Tm, they tend to denature with ease and also easily amplified by denaturation temperature gradient PCR. We also implement a local search molecular algorithm using temperature gradient, which is contrasted to conventional exhaustive search molecular algorithms. The proposed methods are verified by solving an instance of the travelling salesman problem. We could effectively amplify the correct solutions and the use of temperature gradient made the detection of solutions easier.

  • PDF

TiB2-Cu Interpenetrating Phase Composites Produced by Spark-plasma Sintering

  • Kwon, Young-Soon;V. Dudina, Dina;I. Lomovsky, Oleg;A. Korchagin, Michail;Kim, Ji-Soon
    • 한국분말재료학회지
    • /
    • 제10권3호
    • /
    • pp.168-171
    • /
    • 2003
  • Interpenetrating phase composites of $TiB_2$-Cu system were produced via Spark-Plasma Sintering (SPS) oi nanocomposite powders. Under simultaneous action of pressure, temperature and electric current titanium diboride nanoparticles distributed in copper matrix move, agglomerate and form a fine-grained skeleton. Increasing SPS-temperature and he]ding time promote densification due to local melting of copper matrix When copper melting is avoided the compacts contain 17-20% porosity but titanium diboride skeleton is still formed representing the feature of SPS . High degree of densification and formation of titanium diboride network result in increased hardness of high-temperature SPS-compacts.

고온 초전도 퓨즈의 한류 및 방전 특성 (Current Limiting and Discharge Characteristics of High Tc Superconductive Fuse)

  • 최효상
    • 한국전기전자재료학회논문지
    • /
    • 제17권6호
    • /
    • pp.673-677
    • /
    • 2004
  • We present the basic properties of a superconductive fuse (SF) based on YBCO/Au films. The SF consists of YBCO stripes covered with Au layers for current shunt. The fault current was limited to a designed value in less than 0.4 msec by resistance development in YBCO/Au upon quenching. This enabled the SF to transfer small fault power and the suppressed current was sustained for more than 0.5 msec while Au layer melting and arcing. The arcing time was less than 2.5 msec, that is short enough to do self-interruption. Under the source voltage of 100 $V_{rms}$, the longer the duration time of fault current was, the shorter its discharge time was. The duration time of fault current and its discharge time were reduced by increased voltages in the range of 200 - 300 $V_{rms}$. We thought that this was because the quench propagation was limited by local melting generated with higher voltage.age.

Estimation of the Nuclear Power Peaking Factor Using In-core Sensor Signals

  • Na, Man-Gyun;Jung, Dong-Won;Shin, Sun-Ho;Lee, Ki-Bog;Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.420-429
    • /
    • 2004
  • The local power density should be estimated accurately to prevent fuel rod melting. The local power density at the hottest part of a hot fuel rod, which is described by the power peaking factor, is more important information than the local power density at any other position in a reactor core. Therefore, in this work, the power peaking factor, which is defined as the highest local power density to the average power density in a reactor core, is estimated by fuzzy neural networks using numerous measured signals of the reactor coolant system. The fuzzy neural networks are trained using a training data set and are verified with another test data set. They are then applied to the first fuel cycle of Yonggwang nuclear power plant unit 3. The estimation accuracy of the power peaking factor is 0.45% based on the relative $2_{\sigma}$ error by using the fuzzy neural networks without the in-core neutron flux sensors signals input. A value of 0.23% is obtained with the in-core neutron flux sensors signals, which is sufficiently accurate for use in local power density monitoring.

내부 확산법에 의한 $Nb_{3}Sn$ 초전도 선재에서 부분 가열이 초전도 특성에 미치는 영향 (The effect of local heating on superconductivities in internal tin Processed $Nb_{3}Sn$ wires)

  • 하동우;오상수;하홍수;이남진;권영길;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.876-878
    • /
    • 1999
  • Internal tin processed Nb3Sn wires with different diameter were locally heated before reaction heat treatment. Local heating at the intermediate state of drawing process decreased the superconducting properties and workability. When the local heating temperatures were higher than melting point of Sn, non-Cu Jc's decreased significantly.

  • PDF

저온의 순수물속에 잠겨있는 수평 얼음원기둥에 의해 야기되는 자연대류 열전달의 실험적 해석 (Experimental Study of Natural Convectiion Heat Transfer from a Horizontal Ice Cylinder Immersed in Cold Pure Water)

  • 유갑종;추홍록;문종훈
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.1019-1030
    • /
    • 1994
  • Natural convection heat transfer from a horizontal ice cylinder immersed in quiescent cold pure water was studied experimentally. The experiment was conducted for the ambient water temperatures ranging from $2.0^{\cric}C$ to $10.0^{\circ}C$. The flow fields around an ice cylinder and its melting shapes were visualized and local Nusselt numbers obtained. Especially, its attention was focused on the density maximum effects and stagnation point Nusselt number. From the visualized photographs of flow fields, three distinct flow patterns were observed with the ambient water temperature variation. The melting shapes of ice cylinder are various in shape with flow patterns. Steady state upflow was occured at the range of $2.0^{\circ}C \leq T_{\infty} \leq 4.6^{\circ}C$ and steady state downflow was occured at $T_{\infty} \geq 6.0^{\circ}C$. In the range of $4.7^{\circ}C < T_{\infty} < 6.0^{\circ}C$, three-dimensional unsteady state flow was observed. Especially, the melting shapes of ice cylinder have formed the several spiral flutes for the temperatures ranging from $5.5^{\circ}C$ to $5.8^{\circ}C$. For upflow regime, the maximum stagnation point Nusselt number exists at $T_{\infty} = 2.5^{\circ}C$ and as the ambient water temperature increases the Nusselt number decreases. At ambient water temperature of about $5.7^{\circ}C$, Nusselt number shows its minimum value.

다중 GPS를 이용한 변위거동 연구

  • 손호웅;이강원;박은호
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2009년도 춘계학술발표회 논문집
    • /
    • pp.95-100
    • /
    • 2009
  • Global warming melts polar ice, changes ocean currents, creates variation of local climate, and inundates low-altitude regions resulting in disasters to mankind. Accordingly, developed countries including U.S.A. and U.K. spend great amounts of efforts and money to plan and manage research activities on polar ice which is regarded as a key indicator of climate change. The proposed research aims to provide basic information for chasing and monitoring the melting phenomena of polar ice through multiple GPS to enhance the GPS quality.

  • PDF

연속생산공정에서의 유도형 유전알고리즘을 이용한 인과형 예측모델에 관한 연구 (A Causal-Forecasting Model using Guided Genetic Algorithm in Continuous Manufacturing Process)

  • 정호상;정봉주
    • 경영과학
    • /
    • 제17권2호
    • /
    • pp.39-54
    • /
    • 2000
  • This paper presents a causal forecasting model using guided genetic algorithm in continuous manufacturing process. The guide genetic algorithm(GGA) is an extended genetic algorithm(GA) using penalty function and population diversity index to increase forecasting accuracy. GGA adds to the canonical GA the concept of a penalty function to avoid selecting the unproductive chromosomes and to make a proper searching direction. Also, GGA modifies the current population using the similarity of chromosomes to avoid falling into the trap of local optimal solution. For investigation GGA performance, we used a set of real data that was collected in local glass melting processes, and experimental results show the proposed model results in the better forecasting accuracy than linear regression model and canonical GA.

  • PDF

Numerical simulation of the effects of localized cladding oxidation on LWR fuel rod design limits using a SLICE-DO model of the FALCON code

  • Khvostov, Grigori
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.135-147
    • /
    • 2020
  • A methodology for evaluation of mechanical and thermal effects of localized non-axisymmetric oxidation in zircaloy claddings on LWR fuel reliability is proposed. To this end, the basic capabilities of the FALCON fuel behaviour code are used. Examples of methodology application to adjustment of selected operational limits for modern BWR fuel rods, to capture effects of the excess local oxidation, are presented. Specifically, the limiting rod internal pressure for the onset of cladding lift-off is reduced, depending on initial excess oxidation spot sizes. Also, the power limits for Anticipated Operational Occurrences are adjusted, to preclude fuel melting and cladding failure due to PCMI and PCI-SCC in the affected fuel rods.