• Title/Summary/Keyword: Loading tests

Search Result 2,310, Processing Time 0.031 seconds

피로 하중을 받는 철근콘크리트 구조물의 안전성에 관한 연구 (A Study on the Safety of Reinforced Concrete Structures under Fatigue Load)

  • 채원규
    • 한국안전학회지
    • /
    • 제9권2호
    • /
    • pp.18-25
    • /
    • 1994
  • In this thesis, the fatigue tests were performed on a series of reinforced concrete to Investigate the variation of strength and the safety of reinforced concrete structures under fatigue load. The specimens were of the same rectangular cross-section, of effective height 24cm and width 30cm and their span was 330cm. The three point loading system is used in the fatigue tests. In these tests, the fracture mode of reinforced concrete structures under fatigue load, relationship between the repeated loading cycles and the mid-span displacement of the specimens were observed. According to the test results, the following fatigue behavior of reinforced concrete specimens were observed. By increasing of the number of repeated loading cycles, the mid-span displacement became greater, however the Incremental amounts of the displacement were reduced. It could be also known that the inelastic strain energy of the doubly reinforced rectangular beams was larger than that of the singly reinforced rectangular beams as increasing the number of repeated loading cycles. Compliance of reinforced concrete structures tended to be reduced as increasing the repeated loading cycles, and the compliance of the doubly reinforced rectangular beams was generally smaller than that of the singly reinforced rectangular beams. Based on the above investigation, it could be concluded that the doubly reinforced rectangular beams under fatigue load were more efficient to resist the brittle fracture than the singly reinforced rectangular beams.

  • PDF

콘크리트 포장 슬래브의 변형률 측정에 관한 연구 (A Study on the Strain Measurement of Concrete Pavement Slab)

  • 김동호;전성일;최창식;윤병성;윤경구
    • 산업기술연구
    • /
    • 제22권A호
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this paper is to investigate for strain measurement of concrete pavement slab at field. The early-age behaviors of concrete pavement were measured using the strain gages. From the static and dynamic wheel loading tests, the outputs from each gages were recorded. The measured data, also, was compared to those from finite element analysis. The static wheel loading tests were performed in twice, and the dynamic wheel loading tests were performed at the speed 10km-50km. The results could be summarized as follows: To embed the strain gage accurately and stably in concrete pavement, a chair and protective box must be used. The protective box must not be affected from the outside vibrating. From the results of early-age stram measurement, it was found that the strain varied at the maximum value of $180{\mu}{\varepsilon}$ From the results of static wheel loading tests, A1, A2 and B gages generally developed a consistent tendency When comparing the results from the measured at field and the calculated by FEM analysis, the data of A1 and B gages were similar to that from theory. The values from the field test were generally higher than that from the theory. From the results of dynamic wheel loading tests, it was known that the measured strain at field became smaller as the truck speed became faster, Indicating the maximum at the range of $12{\sim}13{\mu}{\varepsilon}$.

  • PDF

선설치앵커의 동적 전단하중에 대한 저항강도: 비보강 앵커 (Shear Resistance of CIP Anchors under Dynamic Loading: Unreinforced Anchor)

  • 박용명;강문기;김동현;이종한;강충현
    • 한국강구조학회 논문집
    • /
    • 제26권1호
    • /
    • pp.11-20
    • /
    • 2014
  • 2001년 이후 앵커의 설계는 Concrete Capacity Design(CCD) 방법이 적용되고 있는데, 국내 기준에서는 지진하중에 대한 콘크리트의 파열파괴강도를 정적 파괴강도의 75%로 제한하고 있다. 본 연구에서는 무근콘크리트에 매입된 선설치앵커의 동적 전단하중에 대한 콘크리트 파열파괴강도 평가하기 위한 실험을 수행하였다. 이를 위해 직경 20 mm의 앵커에 대해 정적 하중과 동적 편진하중에 대한 실험을 각각 3개의 시험체에 대해 수행하였으며, 앵커의 연단거리는 120 mm를 적용하였다. 동적 실험은 15 cycle의 편진하중을 1 Hz의 속도로 재하하였으며 반복하중단계의 크기를 키워가면서 최종 파괴 시까지 가력하였다. 실험으로부터 동적 전단하중에 의한 콘크리트 파열파괴강도는 정적하중에 의한 것과 거의 같은 파괴강도를 보였다.

이방 구속 조건에서 실지진 하중을 이용한 액상화 저항강도 특성 분석 (A Study on the Liquefaction Resistance of Anisotropic Sample under Real Earthquake Loading)

  • 이재진;정상섬;김수일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.1188-1191
    • /
    • 2009
  • In this study, cyclic triaxial tests were performed with the samples which were anisotropically consolidated using irregular earthquake loading to consider in-situ condition and seismic wave. The consolidation pressure ratio(K) was changed from 0.5 to 1.0. The Ofunato and Hachinohe wave are applied as irregular earthquake loading and liquefaction resistance strength was estimated from excess pore water pressure(EPWP) ratio. As results of the cyclic triaxial tests, buildup of EPWP ratio increased as K value increased. It shows, that the isotropically consolidated sands is more susceptible to liquefaction than anisotropically consolidated sands under equal conditions such as confining pressure and dynamic loading.

  • PDF

Tests and numerical behavior of circular concrete-filled double skin steel tubular stub columns under eccentric loads

  • Manigandan R.;Manoj Kumar
    • Structural Engineering and Mechanics
    • /
    • 제88권3호
    • /
    • pp.287-299
    • /
    • 2023
  • This article describes experimental and numerical analyses of eccentrically loaded over the axially loaded circular concrete filled double-skinned steel tubular (CFDST) short columns. Tests on circular CFDST short columns under eccentric and concentric loading were conducted to assess their responses to the frequent intensity of 5-30 mm at the interval of each 5 mm eccentric loading conditions with constant cross-sectional proportions and width-to-thickness ratios of the outside and internal tubes. The non-linear finite-element analysis of circular CFDST short columns of eccentrically loaded over the axially loaded was performed using the ABAQUS to predict the structural behavior and compare the concentric loading capacity over the various eccentric loading conditions. The comparison outcomes show that the axial compressive strength of the circular CDFST short columns was 2.38-32.86%, lesser than the concentrically loaded short column with the inner circular section. Also, the influence of computer simulation employed is more efficient in forecasting the experimentally examined performance of circular CFDST stub columns.

다양한 실내시험을 이용한 지반의 탄성계수 평가 (Evaluation of Modulus of Soils Using Various Laboratory Tests)

  • 권기철;김동수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.345-352
    • /
    • 2000
  • It is very important to evaluate the reliable nonlinear modulus characteristics of soils not only in the analysis of geotechnical structures under working stress conditions but also for the soil dynamic problems. For the evaluation of modulus characteristics of soils, various tests have been mostly employed in laboratory. However, different testing techniques are likely to have different ranges of reliable strain measurements, different applied stress level, and different loading frequencies, and the modulus of soils can be affected by these variables. For reliable evaluation, therefore, those effects on the modulus need to be considered, and measured values should be effectively adjusted to actual conditions where the soil is working. In this paper, to evaluate the modulus characteristics of soils, laboratory testing such as free-free resonant column (FF-RC), resonant column (RC), torsional shear (TS), static TX, and cyclic M/sub R/ tests were performed. The effects of strain amplitude, loading frequency, loading cycles, confining pressure, density, and water content on modulus were investigated. It is shown that the FF-RC test, which is simple and inexpensive testing technique, can provide a reliable estimation of small strain Young's modulus (E/sub max/), and the modulus evaluated by various laboratory tests are comparable to each other fairly well when the effects of these factors are properly taken into account.

  • PDF

수직 및 전단하중하에서 화강암 인공절리의 변형특성 (Deformation Characteristics of Artificially Fracture Joins of Granite under Normal and Shear Loading)

  • 김영근;이희근
    • 터널과지하공간
    • /
    • 제3권2호
    • /
    • pp.142-151
    • /
    • 1993
  • In this study, the deformation characteristics of atrtificially fractured joints of granite under normal and shear loading were investigated. To obtain the characteristics of joint deformation, compression and shear tests were performed in the laboratory on three different sizes of rock specimens. The rock used in the experimens was Iksan granite. Joints were produced artificially by fracturing using the apparatus for generating extension-joint. Joint normal deformability was studied by conducting cyclic loading tests on the joints. Joint closure varied non-linearly with normal stress through cyclic loadings. As normal stress increased, the joints gradually reached a state of maximum joint closure. The relation between normal stress and joint closure for mated and unmated joints was well described by the hyperbolic and exponential function, respectively. Joint shear deformability was studied by performing direct shear tests under normal stresses on the joints. it was shown that the behaviour in the prepeak range was non-linear and joint shear stiffness depended on the size of specimen and the normal stress.

  • PDF

Shear Strength of Grout Type Transverse Joint

  • Kim, Yoon-Chil;Park, Jong-Jin
    • KCI Concrete Journal
    • /
    • 제14권1호
    • /
    • pp.8-14
    • /
    • 2002
  • This is the first of two part series on experimental studies of grout type transverse joints. In this study, grout type transverse joints between precast concrete slabs are statically tested to determine the cracking loads and ultimate shear capacities of the grout type transverse joints. The tests are performed with a loading equipment designed and constructed especially in the lab to induce shear failures on the joints of the test specimens. Shape of the transverse joints, grouting materials and amount of prestress are selected as test parameters for the study. The results indicate that epoxy is an excellent grouting material which can be used in limited locations where large tensile stress is acting on the slab. Longitudinal prestressing is also an effective method to increase the shear strength of the transverse joints. A rational method to estimate the cracking and ultimate loads for the design of grout type transverse joints is proposed based on the static loading tests. Success of the tests with shear loading equipment allowed continuing the research further onto the fatigue strength of the grout type joints, which will be presented in the second part of the paper.

  • PDF

가설 단관 비계의 안전성에 대한 실험적 연구 (An Experimental Study on the Safety of Temporary short pipe Scaffolding)

  • 채원규
    • 한국안전학회지
    • /
    • 제9권4호
    • /
    • pp.85-91
    • /
    • 1994
  • In this thesis, the fracture tests and structural analysis were performed on a series of temporary scaffolding to investigate the variation of strength and the safety of temporary scaffolding. The specimens were of height 270cm and width 50cm and their span was 120cm. The joint loading and member loading were used in the tests, respectively. In these tests, the fracture mode of temporary scaffolding, relationships between the loading and the flexural strain of the specimens were observed. According to the comparison between the test results and the structural analysis results, the effects of the vertical loads and horizontal loads on temporary scaffolding and the safety of temporary scaffolding were studied.

  • PDF

동적하중에 의한 단섬유 보강토의 침하 특성 (Settlement Characteristics of Short-fiber Reinforced Soil under Dynamic Loading)

  • 박영곤;김정기;황선근;신민호
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2002년도 학술발표회 발표논문집
    • /
    • pp.321-324
    • /
    • 2002
  • To analyze the settlement characteristics of short-fiber reinforced soil(SFRS) under dynamic loading, a series of tests with loading condition of 5 Hz frequency and 500,000 cycles were performed. The materials used for tests are a soil of SM type and short-fibers with polypropylene and monofilament or fibrillated type. From the tests, average plastic settlement of SFRS at PPF38(0.3%), PPF38(0.5%), PPM60(0.2%) is low. Elastic settlement of SFRS is low at PPM60(0.2%) and is high at PPF60(0.5% ).

  • PDF