• Title/Summary/Keyword: Loading point

Search Result 1,124, Processing Time 0.026 seconds

Flexural studies on reinforced geopolymer concrete beams under pure bending

  • Sreenivasulu, C.;Jawahar, J. Guru;Sashidhar, C.
    • Advances in concrete construction
    • /
    • v.8 no.1
    • /
    • pp.33-37
    • /
    • 2019
  • The present investigation is mainly focused on studying the flexural behavior of reinforced geopolymer concrete (RGPC) beams under pure bending. In this study, copper slag (CS) was used as a partial replacement of fine aggregate. Sand and CS were blended in different proportions (100:0, 80:20, 60:40 and 40:60) (sand:CS) by weight. Fly ash and ground granulated blast furnace slag (GGBS) were used as binders and combination of sodium hydroxide (8M) and sodium silicate solution were used for activating the binders. The reinforcement of RGPC beam was designed as per guidelines given in the IS 456-2000 and tested under pure bending (two-point loading) after 28 days of ambient curing. After conducting two point load test the flexural parameters viz., moment carrying capacity, ultimate load, service load, cracking moment, cracking load, crack pattern and ultimate deflection were studied. From the results, it is concluded that RGPC beams have shown better performance up to 60% of CS replacement.

Ductile Fracture Behaviour of SA 533B Pressure Vessel Steel Under Mixed Mode (I/II) Loading (혼합 모드(I/II) 하중에 의한 SA533B 압력용기강의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1829-1834
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bonding tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, the fractographic examination of fracture surfaces was carried out to compare with those of pure Mode I and Mode II. In conclusions, the J-R curves under Mixed Mode (I/II) loading were located between those of Mode I and Mode II loadings. When the mixture ratio of mixed mode (I/II) loading was high, the J-R currie of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixture ratio was low, the J-R curve looked after that of pure mode II loading. The fractographic evidences such as the shape of dimples under different loading conditions supported these conclusions.

Fatigue Life Estimation Using the Multi-Axial Multi-Point Load Counting Method under Variable Amplitude Loading (가변진폭하중하에서 다축-다점 하중 Counting method를 이용한 피로수명평가)

  • Lee, W.S.;Lee, H.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.6
    • /
    • pp.22-27
    • /
    • 1997
  • In general, the load which acts on the structure is almost independent of time in many locations. In this case. It is difficult to estimate the life with the service load history, because the structure is on the multi- axial and multi-point loading states. In this study, the service load of the excavator which is widely used in industry field was calculated using measured cylinder pressures and displacements. The fatigue life was estimated using the multi-axial and multi-point load counting method. Service load history of 4 pin joint which act independently each other is yielded by mult-axial and multi-point load counting method. The stress spectrum is yielded by superposition of the results of FEM stress analysis applied unit load. Palm- gren-Miner's cumulative Damage is 0.000804 for Von Mises equivalent stress sequence by one side fillet weld S-N curve. This result agress with Bench test results. As a result of this study, the fatigue life esti- mation using the multi-axial and multi-axial and multi-point load counting method is useful.

  • PDF

Runoff Characteristics and Non-point Source Pollution Loads from Cheongyang-Hongseong Road (청양-홍성간 도로에서의 강우 시 비점오염 유출특성 및 오염부하량 분석)

  • Lee, Chun-Won;Kang, Seon-Hong;Ahn, Tae-Woong;Yang, Joo-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.2
    • /
    • pp.265-274
    • /
    • 2011
  • Nowadays, the importance of non-point source pollution treatment is being emphasized. Especially, the easy runoff characteristic of highly concentrated pollutants in the roads makes the circumstance more complicated due to impermeability of roads. When the pollutants flow into steam it could make water quality in stream worse and it also causes a bad influence in the aquatic ecosystem because the effluents of rainfall-runoff may contain indecomposable materials like oil and heavy metals. Therefore, we tried to figure out the property of non-point source pollution when it is raining and carried out an assessment for the property of runoff for non-point source pollution and EMC (Event Mean Concentrations) of the essential pollutants during this study. As the result of the study, the EMC was BOD 5.2~21.7 mg/L, COD 7.5~35.4 mg/L, TSS 71.5~466.1 mg/L, T-N 0.682~1.789 mg/L and T-P 0.174~0.378 mg/L, respectively. The decreasing rate of non-point pollutant in Chungyang-Hongsung road indicates the maximum decrease of 80% until 5 mm of rainfall based on SS concentration; by the rainy time within 20~30 minutes, the decreasing rate of SS concentration was shown as 88.0~97.6%. Therefore it was concluded that it seems to be possibly control non-point pollutants if we install equipments to treat non-point pollutants with holding capacity of 30 min. It is supposed that the result of this study could be used for non-point pollutants treatment of roads in Chungyang-Hongsung area. We also want to systematically study and consistently prepare the efficient management of runoff from non-point source pollution and pollutant loading because the characteristics of non-point source pollution runoff changes depending on different characteristics and situations of roads and rainfall.

A new approach for measurement of anisotropic tensile strength of concrete

  • Sarfarazi, Vahab;Faridi, Hamid R.;Haeri, Hadi;Schubert, Wulf
    • Advances in concrete construction
    • /
    • v.3 no.4
    • /
    • pp.269-282
    • /
    • 2015
  • In this paper, a compression to tensile load converter device was developed to determine the anisotropic tensile strength of concrete. The samples were made from a mixture of water, fine sand and cement, respectively. Concrete samples with a hole at its center was prepared and subjected to tensile loading using the compression to tensile load converter device. A hydraulic load cell applied compressive loading to converter device with a constant pressure of 0.02 MPa per second. Compressive loading was converted to tensile stress on the sample because of the overall test design. The samples have three different configurations related to loading axis; 0, $45^{\circ}$, $-45^{\circ}$. A series of finite element analysis were done to analyze the effect of hole diameter on stress concentration of the hole side along its horizontal axis to provide a suitable criterion for determining the real tensile strength of concrete. Concurrent with indirect tensile test, Brazilian test and three point loading test were also performed to compare the results from the three methods. Results obtained by this device were quite encouraging and show that the tensile strengths of concrete were similar in different directions because of the homogeneity of bonding between the concrete materials. Also, the indirect tensile strength was clearly lower than the Brazilian test strength and three point loading test.

Marginal bone level change during sequential loading periods of partial edentulous rehabilitation using immediately loaded self-tapping implants: a 6.5-year retrospective study

  • Wang, Jing;Zhang, Zhengchuan;Deng, Feilong
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.133-142
    • /
    • 2022
  • PURPOSE. A large number of studies have suggested the practicability and predictability of immediate implant function, but few studies have reported marginal bone level changes during sequential loading periods. The purpose of this study was to evaluate the marginal bone remodeling of immediately loaded self-tapping implants both at each time point and during each loading period between two time points. MATERIALS AND METHODS. The patients included in this retrospective study were treated with immediately loaded NobelSpeedy Replace implants between August 2008 and July 2009. Differences in the marginal bone level (MBL) at each time point and the marginal bone level change (ΔMBL) between two time points were analyzed with Bonferroni correction (P < .05). RESULTS. Overall, 24 patients (mean age, 47.3 ± 12.8 years) with 42 immediately loaded implants and a median follow-up of 6.5 years (IQR, 67.8 months) were included. The cumulative survival rate after 10 - 12 years was 95.2%. Continuous but slow marginal bone loss was observed during long-term follow-up. MBL at both 7.5 years and 11 years was significantly lower than that at loading, 6 months, 2 years and 4 years (P < .05). No bone loss difference was found in any period before 4 years of follow up (P > .05). The loading period of 4 years to 7.5 years showed the largest ΔMBL compared to those of other time periods (P < .05). CONCLUSION. Slight bone loss occurred continuously, and more radical changes of marginal bone can be observed during the period of 4-7.5 years. Thus, long-term effective follow-up of immediately loaded implants is needed.

Effect of direct member loading on space truss behaviour

  • El-Sheikh, Ahmed
    • Structural Engineering and Mechanics
    • /
    • v.10 no.1
    • /
    • pp.1-15
    • /
    • 2000
  • It is inevitable that every space truss structure would be under some form of direct member loading. At least the structure self weight certainly affects the members directly, and in structures involving top concrete slabs or cladding, their weight is also likely to apply some lateral pressure on the members. In spite of that, direct member loading is usually ignored in space truss designs and assumed to lead only to a negligible effect on truss performance. This study is intended to explore this point and identify the actual effects that can arise from direct member loading, and eventually provide an answer to the question of whether the current design practice is satisfactory or certain modifications would be needed. After presenting two analytical techniques to allow the study of space trusses with laterally loaded members, the paper describes a wide parametric study involving practical-size space trusses with different configurations, aspect ratios, boundary conditions and number of chord panels.

Sreamflow, Nutirnets loading estimation for KEUMGANG estrury using SWAT2000 model (SWAT2000 모형을 이용한 금강하구호의 유출량 및 영양염류 부하량 산정)

  • Moon, Jong-Pil;Kim, Tai-Cheol
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.496-501
    • /
    • 2005
  • SWAT2000 model directly estimate the loading of water, and nutrients from land areas in a watershed. it allows to add nutrient loading from the point sourece like a sewage treatment plant and it also has a GIS interface which can easily see the spatial relationship between subbasins. For better assessment of nutrients loading to KEUMGANG estuary, SWAT2000 model applied to KEUMGANG estuary watershed. Model calibration and verification was firstly poerformed at Gongju site duing the period $1999{\sim}2003$. $R^2$ value was 0.96 for streamflow, 0.94 for T-N load and 0.52 for T-P load. The accuracy of the model at Gongju site suggest that the SWAT2000 can be available to estimate streamflow, Nutrients loading to the KEUMGANG estuary.

  • PDF

Characteristics of Agricultural Non-point Source Pollutants by Rainfall Events in Rural Watersheds (농촌유역의 강우사상별 농업 비점원오염물질 유출특성)

  • Kim, Jinho;Han, Kukheon;Lee, Jongsik
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2008
  • This study was conducted to know the characteristics of agricultural non-point source pollutants runoff by rainfall events at the upper catchment of Goseong reservoir in Gonjy city, Chungnam Province. For this study, the monitoring sites of the research catchment were set nineteen during the research period (between June 2005 and October 2006). Average runoff coefficient were observed 0.51 in 2005, 0.71 in 2006, respectively. The correlation coefficient (r) between the rainfall and peak-flow was investigated 0.787. By rainfall events, the water quality of the sites were shown like this : BOD 0.555~9.60 mg/L, T-N 0.01~13.50 mg/L, T-P 0.002~2.952 mg/L, and SS N.D~820.0 mg/L. The strong rainfall intensity was the most important factor of the soil erosion. The gabs of the arithmetic mean concentrations and the flow weighted mean concentrations were observed as the followings : BOD 0.0~29.2%, T-N 0.1~11.4%, T-P 0.4~95.2%, and SS 1.7~57.0% in 2005, and BOD 1.0~11.9%, T-N 0.7~7.3%, T-P 9.9~36.5%, and SS 6.6~36.5% in 2006, respectively. The BOD pollution load was 2,117 kg (36% of the total BOD loading of survey periods) while, T-N was 3,209.0 kg (27.9% of the total T-N loading of survey periods), T-P was 136.4 kg (37.4% of the total T-P loading of survey periods) and SS was 72,733.8 kg (51.8% of the total SS loading of survey periods) in the year 2005. In case of 2006, BOD load was 1,321.7, T-N was 2,845.8, T-P was 42.9, and SS was 16,275.8 kg, respectively.

Three point bending test of recycled Nickel-Titanium alloy wires (재생한 니켈 티타늄 호선의 3점 굴곡물성실험)

  • Lee, Sung-Ho;Chang, Young Il
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.731-738
    • /
    • 2000
  • The purpose of this study was to investigate the change of 3 point bending properties of various nickel titanium wires after recycling. Four Types of nickel-titanium (Align: martensitic type, NiTi, Optimalloy, Sentalloy: austenitic type) wires were divided to three groups: as-received condition (T0: control group), treated in artificial saliva for four weeks (T1) and autoclaved after being treated in artificial saliva (T2). Detrimental changes were observed for the selected mechanical properties in three point bending test. Loading force at 3mm deflection, unloading force at 3mm deflection, stress hysteresis, loading force at 1mm deflection, unloading force at 1mm deflection and stress hysteresis at 1mm deflection were calculated. The findings suggest that : 1. Align demonstrated statistically significant increase In loading force (p<0.05) and unloading force (p<0.01) at 3mm deflection after recycling(T2), but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling. 2. Align demonstrated statistically significant decrease in hysteresis(p<0.01) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically significant difference after recycling. 3. All wires showed no statistically significant difference in loading force at 1mm deflection after recycling(T2). 4. Align demonstrated statistically significant decrease in unloading force in 1mm deflection (p<0.05) after recycling(T2) but NiTi, Optimalloy and Sentalloy showed no statistically difference after recycling 5. Loading force and unloading force of T1 showed no significant change compared with those of T0, but loading force and unloading force of T2 showed significant changes compared with those of T0(p<0.05, p<0.01 respectively). 6. Align demonstrated a tendency to lose some of this pseudoelasticity in T1 and pseudoplasticity and pseudoelasticity in T2.

  • PDF