• Title/Summary/Keyword: Loading Data

Search Result 2,110, Processing Time 0.024 seconds

Removal of Synthetic Heavy Metal ($Cr^{6+}$, $Cu^{2+}$, $As^{3+}$, $Pb^{2+}$) from Water Using Red Mud and Lime Stone (적니와 석회석을 이용한 혼합 중금속($Cr^{6+}$, $Cu^{2+}$, $As^{3+}$, $Pb^{2+}$)의 제거)

  • Kang, Ku;Park, Seong-Jik;Shin, Woo-Seok;Um, Byung-Hwan;Kim, Young-Kee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.566-573
    • /
    • 2012
  • This study examined the removal rate of heavy metals from synthetic control water using red mud and lime stone. Overall, the percent of absorption obtained in this study for the red mud treatment was 94.0% ($Pb^{2+}$), 67.1% ($As^{3+}$), 37.5% ($Cu^{2+}$), and 36.6% ($Cr^{6+}$), while that of lime stone was $Pb^{2+}$ (30.8%), $Cu^{2+}$ (16.5%), $Cr^{6+}$ (11.5%), and $As^{3+}$ (8.9%). The kinetic data presented that the slow course of adsorption follows the Pseudo first and second order models, the equilibriuim adsorption of $Cr^{6+}$ and $Pb^{2+}$ obeys Freundlich isotherm model, while the adsorption of $Cu^{2+}$ obeys only Langmuir model. The results also showed that adsorption rate slightly increased with increasing pH from 5 to 9. Interestingly, this trend is similar to results obtained as function of loading amount of red mud. Meanwhile, an unit adsorption rate was slightly decreased. For lime stone, it did not much change in adsorption as function of treatment amount. Consequently, it was concluded that the absorbents can be successfully used the removal of the heavy metals from the aqueous solutions.

Spatial and Temporal Variations of Water Quality in an Urban Miho Stream and Some Influences of the Tributaries on the Water Quality (청주지역의 도심하천인 미호천에서 시공간적 수질변이 특성 및 유입지천의 영향)

  • Kim, Ji-Il;Choi, Ji-Woong;An, Kwang-Guk
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.433-445
    • /
    • 2014
  • The objective of study was to analyze seasonal and inter-annual patterns of water chemistry of Miho Stream watershed during 2004 - 2007 along with some influences of tributaries and summer monsoon on the stream water quality. For the study, eight physico-chemical parameters such as nitrogen, phosphorus, BOD, COD and chlorophyll-a (CHL) etc. were analyzed in relation to spatial and temporal variability of seven sampling sites of the mainstream and some tributaries in the watershed. In the upstream reach, Mean of BOD, COD and TP averaged 3.2 mg/L, 6.5 mg/L and $186{\mu}g/L$, respectively, indicating an eutrophic conditions as a III-rank in the stream water quality criteria from the Ministry of Environment, Korea(MEK). The eutrophic water was due to a combined effect of Chiljang tributary with high nutrients ($TP=844{\mu}g/L$, TN=8.087 mg/L) and the point sources from some wastewater treatment plants. In the meantime, BOD, TN, and TP in the downstream reach were about > 1.2-1.5 folds than the values of the midstream reaches. This was mainly attributed to effluents of nutrient rich-water (mean TN: 11.980 mg/L) from two tributaries of Musim Stream and Suknam Stream, which is directly influenced by nearby wastewater disposal plants. Seasonal analysis of water chemistry showed that summer monsoon rainfall was one of the important factors influencing the water quality, and water quality had a large spatial heterogeneity during the rainfall period. In the premonsoon, BOD in the downstream averaged $6.0{\pm}2.47mg/L$, which was 1.4-fold greater than the mean of upstream reach. Mean of CHL-a as an indicator of primary productivity in the water body, was > 2.2 - 2.9 fold in the downstream than in the upstream, and this was a result of the high phosphorus loading from the watershed. Overall, our data suggest that some nutrient controls in point-source tributary streams are required for efficient water quality management of Miho Stream.

Dynamic Response of Plate Structure Subject to the Characteristics of Explosion Load Profiles - Part A: Analysis for the Explosion Load Characteristics and the Effect of Explosion Loading Rate on Structural Response - (폭발하중 이력 특성에 따른 판 구조물의 동적응답 평가 - Part A: 폭발하중 특징 및 재하속도의 영향 분석 -)

  • Kang, Ki-Yeob;Choi, Kwang-Ho;Ryu, YongHee;Choi, JaeWoong;Lee, Jae-Myung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.187-195
    • /
    • 2015
  • The gas explosions in offshore installations are known to be very severe according to its geometry and environmental conditions such as leak locations and wind directions, and a dynamic response of structures due to blast loads depends on the load profile. Therefore, a parametric study has to be conducted to investigate the effects of the dynamic response of structural members subjected to various types of load shapes. To do so, a series of CFD analyses was performed using a full-scale FPSO topside model including detail parts of pipes and equipments, and the time history data of the blast loads at monitor points and panels were obtained by the analyses. In this paper, we focus on a structural dynamic response subjected to blast loads changing the magnitude of positive/negative phase pressure and time duration. From the results of linear/nonlinear transient analyses using single degree of freedom(SDOF) and multi-degree-of freedom(MDOF) systems, it was observed that dynamic responses of structures were significantly influenced by the magnitude of positive and negative phase pressures and negative time duration.

Influence of internal connection length on screw loosening in internal connection implants (내측 연결 임플란트에서 지대주 내부길이가 나사 풀림에 미치는 영향)

  • Kim, Ji-Sun;Park, Young-Bum;Choi, Hynmin;Kim, Sungtae;Kim, Hyeon Cheol;Kim, Sun Jai;Moon, Hong-Seok;Lee, Jae-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.251-257
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate whether the internal abutment length affected screw stability in an internal connection implant. Materials and methods: Twenty long internal connection implants (Replus system, $4.7{\times}11.5mm$) were selected for this investigation. Abutments were assigned to four groups depending on the length of the internal connection (abutments with internal lengths of 1, 2, 3, and 4 mm, respectively). Each implant fixture specimen was embedded in resin medium and connected to an abutment with an abutment screw. A load of 100 N, applied at an angle of $30^{\circ}$ to the long axis of the implant, was repeated for $1.0{\times}10^6$ cycles. Reverse torque values (RTV) were recorded before and after loading, and the change in RTV was calculated. Data were analyzed with the Kruskal-Wallis test. Results: The change in RTV was not significantly different among the groups (P>.05). Screw loosening and fractures were not observed in any groups, and joint stability was maintained. Conclusion: The internal length of the abutment may not significantly affect the degree of screw loosening.

Verification of Numerical Analysis Technique of Dynamic Response of Seabed Induced by the Interaction between Seabed and Wave (파랑-지반 상호작용에 의한 해저지반의 동적응답 수치해석법 검증)

  • Kang, Gi-Chun;Kim, Sung-Woung;Kim, Tae-Hyung;Kim, Do-Sam;Kim, Jae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.1
    • /
    • pp.5-14
    • /
    • 2015
  • Seabed may undergo large excess pore water pressure in the case of long duration of high wave loading. This excess pore water pressure may reduce effective stress and, consequently, the seabed may liquefy. Thus, it is necessary to develop a numerical technique which can precisely evaluate the dynamic response of seabed due to wave action. In this study, a new numerical technique named mixed model (2D NIT & FLIP models) was proposed. The dynamic wave pressure and water flow velocity acting on the boundary between seabed and the wave field was estimated using 2D-NIT model. This result was used as input data in FLIP program for investigation of dynamic response of seabed. To secure the reliability of the mixed model, the numerical analysis results of the mixed model were compared with Yamamoto's solution and Chang's experiment results. The comparison results indicated that there were some differences between them, but the general trend of the effective stress increment and the excess pore water pressure along the depth of seabed was similar to each other. Thus, this study clearly supports the plausibility of the numerical analysis of the mixed model.

Discrimination of Cultivars and Cultivation Origins from the Sepals of Dry Persimmon Using FT-IR Spectroscopy Combined with Multivariate Analysis (FT-IR 스펙트럼 데이터의 다변량 통계분석을 이용한 곶감의 원산지 및 품종 식별)

  • Hur, Suel Hye;Kim, Suk Weon;Min, Byung Whan
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.20-26
    • /
    • 2015
  • This study aimed to establish a rapid system for discriminating the cultivation origins and cultivars of dry persimmons, using metabolite fingerprinting by Fourier transform infrared (FT-IR) spectroscopy combined with multivariate analysis. Whole-cell extracts from the sepals of four Korean cultivars and two different Chinese dry persimmons were subjected to FT-IR spectroscopy. Principle component analysis (PCA) and partial least squares discriminant analysis (PLS-DA) of the FT-IR spectral data successfully discriminated six dry persimmons into two groups depending on their cultivation origins. Principal component loading values showed that the 1750-1420 and $1190-950cm^{-1}$ regions of the FT-IR spectra were significantly important for the discrimination of cultivation origins. The accuracy of prediction of the cultivation origins and cultivars by PLS regression was 100% (p<0.01) and 85.9% (p<0.05), respectively. These results clearly show that metabolic fingerprinting of FT-IR spectra can be applied for rapid discrimination of the cultivation origins and cultivars of commercial dry persimmons.

Study on Developing Instrument System for Measuring Action time of K4 Grenade Machine Gun for Improving Quality Assurance on 40mm High Velocity Grenade (40mm 고속유탄의 품질보증 향상을 위한 K4 기관총의 Action Time 계측시스템 개발에 관한 연구)

  • Hong, Sung-Kook;Shin, Jun-Goo;Jeon, Hye-Jin;Kim, Yong-Hwa;Ju, Jin-Chun;Kwon, In-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4828-4834
    • /
    • 2015
  • From the moment that a firing pin triggers the detonator to the moment that a grenade leaves a barrel is called Action Time. Since a loading and percussion of 40mm grenade happens simultaneously, action time should be within a certain time in order to prevent a Jamming malfunction. Previously, unreliable action time device of 40mm grenade made it difficult to improve quality assurance of K4 Grenade Machine Gun. Here, various sensors were compared and a special device was designed to seek an accurate measurement on action time. In this device, the gap between a signal from an optical sensor in Firing Pin and that from Eddy current probe in the barrel was recorded and data were sent to a computer in real time. Confirming if action time is within the criteria, it is expected that action time plays an important role in quality assurance on 40mm grenade.

Hardware-Based High Performance XML Parsing Technique Using an FPGA (FPGA를 이용한 하드웨어 기반 고성능 XML 파싱 기법)

  • Lee, Kyu-hee;Seo, Byeong-seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.12
    • /
    • pp.2469-2475
    • /
    • 2015
  • A structured XML has been widely used to present services on various Web-services. The XML is also used for digital documents and digital signatures and for the representation of multimedia files in email systems. The XML document should be firstly parsed to access elements in the XML. The parsing is the most compute-instensive task in the use of XML documents. Most of the previous work has focused on hardware based XML parsers in order to improve parsing performance, while a little work has studied parsing techniques. We present the high performance parsing technique which can be used all of XML parsers and design hardware based XML parser using an FPGA. The proposed parsing technique uses element analyzers instead of the state machine and performs multibyte-based element matching. As a result, our parsing technique can reduce the number of clock cycles per byte(CPB) and does not need to require any preprocessing, such as loading XML data into memory. Compared to other parsers, our parser acheives 1.33~1.82 times improvement in the system performance. Therefore, the proposed parsing technique can process XML documents in real time and is suitable for applying to all of XML parsers.

Comuarative Evaluation on Strength of Several Grout-filled Splice Sleeve (각종 그라우트 충전식 철근이음의 내력에 대한 비교평가)

  • Kim Hyong-Kee
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.635-643
    • /
    • 2004
  • In this study, the tensile strength of 321 full-sized grout-filled splice steeve specimens were compared and analyzed in order to afford the data for a reasonable and economical design of this system. The experimental variables analyzed in this study were embedment length of reinforcing bars, compressive strength of grout, sleeve geometry, loading pattern and final failure mode of specimen. Following main conclusions are obtained : 1) The strength of grout-filled splice sleeve tends to be improved with increasing compressive strength of grout and embedment length of reinforcing bars. Specially this tendency appears apparent in specimens of bond failure rather than rebar failure. 2) The results of this study show that the sleeve geometry have influence on the bond strength of grout-filled splice sleeve. 3) The grout-filled splice sleeve of bond failure don't show the difference of tensile strength according to size of rebar. 4) It is verified that the tensile strength required in ACI and domestic code is retained either when the compressive strength of grout over 70 MPa is used with embedment length of reinforcing bars over 4.5d or when the compressive strength of grout over 80 MPa is used with embedment length of rebars over 3.9d. 5) It is verified that the tensile strength required in AIJ code is retained in case when the embedment length of reinforcing bars is 0.8 times the rebar diameter longer than in ACI code.

Development of a Stereotactic Radiosurgery Planning System (뇌정위 방사선수술을 위한 컴퓨터 치료계획시스템의 개발)

  • 조병철;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.17-24
    • /
    • 1997
  • We developed PC-based planning system for linear accelerator based stereotactic radiosurgery. The system was developed under Windows 95 on Pentium Pro$\^$(R) 200 ㎒ IBM PC with 128 MB RAM. It was programed using IDL$\^$(R)/ of Research Systems, Inc. as a programing tool. CT image data obtained with BRW stereotactic frame is transferred to PC through magnetoptical disk. As loading the image, the system automatically recognizes the location of rods and establishes stereotactic coordinates. It accurately calculates and corrects the coordinates, degree of tilting, and magnification rate of axial images. After the coordinates is defined we can delineate and edit the contours of target and organs of interest on axial images. Upon delineating contours of target, isocenter is determined automatically and we can set up the beam configuration for radiosurgery. The system provides beam's eye view and room's eye view for efficient confuguring of beams. The system calculates dose distribution 3-dimensionally. It takes 1 to 2 minutes to calculate dose distribution for 5 arcs. We can verify the dose distribution on serial axial images. We can analyze the dose distribution quantitatively by evaluation of dose-volume histogram of target and organ of interest. This system, PC-based radiosurgery planning system, includes the basic features for radiosurgery planning and calculates dose distribution within reasonable time for clinical application.

  • PDF