• Title/Summary/Keyword: Loading Data

Search Result 2,116, Processing Time 0.029 seconds

Thermo-mechanical vibration analysis of curved imperfect nano-beams based on nonlocal strain gradient theory

  • Ebrahimi, Farzad;Daman, Mohsen;Mahesh, Vinyas
    • Advances in nano research
    • /
    • v.7 no.4
    • /
    • pp.249-263
    • /
    • 2019
  • In the current paper, an exact solution method is carried out for analyzing the thermo-mechanical vibration of curved FG nano-beams subjected to uniform thermal environmental conditions, by considering porosity distribution via nonlocal strain gradient beam theory for the first time. Nonlocal strain gradient elasticity theory is adopted to consider the size effects in which the stress for not only the nonlocal stress field but also the strain gradients stress field is considered. It is perceived that during manufacturing of functionally graded materials (FGMs) porosities and micro-voids can be occurred inside the material. Material properties of curved porous FG nanobeam are assumed to be temperature-dependent and are supposed to vary through the thickness direction of beam which modeled via modified power-law rule. Since variation of pores along the thickness direction influences the mechanical and physical properties, porosity play a key role in the mechanical response of curved FG nano-structures. The governing equations and related boundary condition of curved porous FG nanobeam under temperature field are derived via the energy method based on Timoshenko beam theory. An analytical Navier solution procedure is utilized to achieve the natural frequencies of porous FG curved nanobeam supposed to thermal loading. The results for simpler states are confirmed with known data in the literature. The effects of various parameters such as nonlocality parameter, porosity volume fractions, thermal effect, gradient index, opening angle and aspect ratio on the natural frequency of curved FG porous nanobeam are successfully discussed. It is concluded that these parameters play key roles on the dynamic behavior of porous FG curved nanobeam. Presented numerical results can serve as benchmarks for future analyses of curve FG nanobeam with porosity phases.

Strength Characterisation of Composite Securement Device in the Vehicle by FE Analysis (유한요소해석을 통한 차량내 복합재 휠체어 고정구의 구조 강도 특성 평가)

  • Ham, Seok-Woo;Yang, Dong-Gyu;Son, Seung-Neo;Eo, Hyo-Kyoung;Kim, Gyeong-Seok;Cheon, Seong S.
    • Composites Research
    • /
    • v.32 no.4
    • /
    • pp.171-176
    • /
    • 2019
  • In this paper, the strength of the composite securement device was characterised by FE analysis. Preliminary frontal crash analysis for the vehicle, equipped with the conventional steel securement device, was carried out according to the ISO 10542 for special transportation to obtain loading data, which were applied to securement device during crash. The securement device consists of block, guide and rail and the weight fraction of rail was the highest among them, therefore, it is desirable to reduce weight of rail by applying carbon/epoxy composite. Also, it was found that 27% of lightweight effect was obtained by hybrid rail that bottom part was replaced by a composite compared to the conventional rail, i.e., made of SAPH 440, without sacrificing the structural strength.

The push-out bond strength of BIOfactor mineral trioxide aggregate, a novel root repair material

  • Akbulut, Makbule Bilge;Bozkurt, Durmus Alperen;Terlemez, Arslan;Akman, Melek
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.1
    • /
    • pp.5.1-5.9
    • /
    • 2019
  • Objectives: The aim of this in vitro study was to evaluate the push-out bond strength of a novel calcium silicate-based root repair material-BIOfactor MTA to root canal dentin in comparison with white MTA-Angelus (Angelus) and Biodentine (Septodont). Materials and Methods: The coronal parts of 12 central incisors were removed and the roots were embedded in acrylic resin blocks. Midroot dentin of each sample was horizontally sectioned into 1.1 mm slices and 3 slices were obtained from each root. Three canal-like standardized holes having 1 mm in diameter were created parallel to the root canal on each dentin slice with a diamond bur. The holes were filled with MTA-Angelus, Biodentine, or BIOfactor MTA. Wet gauze was placed over the specimens and samples were stored in an incubator at $37^{\circ}C$ for 7 days to allow complete setting. Then samples were subjected to the push-out test method using a universal test machine with the loading speed of 1 mm/min. Data was statistically analyzed using Friedman test and post hoc Wilcoxon signed rank test with Bonferroni correction. Results: There were no significant differences among the push-out bond strength values of MTA-Angelus, Biodentine, and BIOfactor MTA (p > 0.017). Most of the specimens exhibited cohesive failure in all groups, with the highest rate found in Biodentine group. Conclusions: Based on the results of this study, MTA-Angelus, Biodentine, and BIOfactor MTA showed similar resistances to the push-out testing.

A Study on DEA-based Stepwise Benchmarking Target Selection Considering Resource Improvement Preferences (DEA 기반의 자원 개선 선호도를 고려한 단계적 벤치마킹 대상 탐색 연구)

  • Park, Jaehun;Sung, Si-Il
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.1
    • /
    • pp.33-46
    • /
    • 2019
  • Purpose: This study proposed a DEA (Data Envelopment Analysis)-based stepwise benchmarking target selection for inefficient DMU (Decision Making Unit) to improve its efficiency gradually to reach most efficient frontier considering resource (DEA inputs and outputs) improvement preferences. Methods: The proposed method proceeded in two steps. First step evaluates efficiency of DMUs by using DEA, and an evaluated DMU selects benchmarking targets of HCU (Hypothesis Composit Unit) or RU (Real Unit) considering resource improvement preferences. Second step selects stepwise benchmarking targets of the inefficient DMU. To achieve this, this study developed a new DEA model, which can select a benchmarking target of an inefficient DMU in considering inputs or outputs improvement preference, and suggested an algorithm, which can select stepwise benchmarking targets of the inefficient DMU. Results: The proposed method was applied to 34 international ports for validation. In efficiency evaluation, five ports was evaluated as most efficient port, and the remaining 29 ports was evaluated as relative inefficient port. When port 34 was supposed as evaluated DMU, its can select its four stepwise benchmarking targets in assigning the preference weight to inputs (berth length, total area of pier, CFS, number of loading machine) as (0.82, 1.00, 0.41, 0.00). Conclusion: For the validation of the proposed method, it applied to the 34 major ports around the world and selected stepwise benchmarking targets for an inefficient port to improve its efficiency gradually. We can say that the proposed method enables for inefficient DMU to establish more effective and practical benchmarking strategy than the conventional DEA because it considers the resource (inputs or outputs) improvement preference in selecting benchmarking targets gradually.

Frictional responses of concrete-to-concrete bedding planes under complex loading conditions

  • Dang, Wengang;Konietzky, Heinz;Li, Xiang
    • Geomechanics and Engineering
    • /
    • v.17 no.3
    • /
    • pp.253-259
    • /
    • 2019
  • Concrete-to-concrete bedding planes (CCBP) are observed from time to time due to the multistep hardening process of the concrete materials. In this paper, a series of direct/cyclic shear tests are performed on CCBP under static and dynamic normal load conditions to study the frictional behavior effect by the shear velocities, normal impact frequencies, horizontal shear frequencies, normal impact force amplitudes, horizontal shear displacement amplitudes and normal load levels. According to the experimental results, apparent friction coefficient k ($k=F_{Shear}/F_{Normal}$) shows different patterns under static and dynamic load conditions at the stable shear stage. k is nearly constant in direct shear tests under constant normal load conditions (DCNL), while it is cyclically changing with nearly constant peak value and valley value for the direct shear tests under dynamic normal load conditions (DDNL), where k increases with decreasing normal force and decreases with increasing normal force. Shear velocity has little influence on peak values of k for the DCNL tests, but increasing shear velocity leads to increasing valley values of k for DDNL tests. It is also found that, the valley values of k ascend with decreasing impact normal force amplitude in DDNL tests. The changing pattern of k for the cyclic shear tests under constant and dynamic normal load conditions (CCNL and CDNL tests) are similar, but the peak value of k is smaller in CDNL tests than that in CCNL tests. Normal load levels, shear displacement amplitudes, vertical impact frequencies, horizontal shear frequencies and normal impact force amplitudes have little influence on the changing pattern of k for the cyclic shear tests. The tests of this study provide useful data in understanding the frictional behavior of the CCBP under distinct loadings, and these findings are very important for analyzing the stability of the jointed geotechnical structures under complicated in situ stress conditions.

Need-to-knows about Digital Implant Surgery (디지털 가이드 수술의 이해와 임상적 적용)

  • Paek, Janghyun;Kwon, Kung-Rock;Kim, Hyeong-Seob;Pae, Ahran;Noh, Kwantae;Hong, Sung-Jin;Lee, Hyeon-jong
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.631-640
    • /
    • 2018
  • Nowadays computer-guided "flapless" surgery for implant placement using templates is gaining popularity among clinicians and patients. The advantages of this surgical protocol are its minimally invasive nature, accuracy of implant placement, predictability, less post-surgical discomfort and reduced time required for definitive rehabilitation. Aim of this study is to describe the digital implant protocol, thanks to which is now possible to do a mini-invasive static guided implant surgery. This is possible thanks to a procedure named surface mapping based on the matching between numerous points on the surface of patient's dental casts and the corresponding anatomical surface points in the CBCT data. With some critical points and needing an adequate learning curve, this protocol allows to select the ideal implant position in depth, inclination and mesio-distal distance between natural teeth and or other implants enabling a very safe and predictable rehabilitation compared with conventional surgery. It represents a good tool for the best compromise between anatomy, function and aesthetic, able to guarantee better results in all clinical situations.

  • PDF

Behavior of composite box bridge girders under localized fire exposure conditions

  • Zhang, Gang;Kodur, Venkatesh;Yao, Weifa;Huang, Qiao
    • Structural Engineering and Mechanics
    • /
    • v.69 no.2
    • /
    • pp.193-204
    • /
    • 2019
  • This paper presents results from experimental and numerical studies on the response of steel-concrete composite box bridge girders under certain localized fire exposure conditions. Two composite box bridge girders, a simply supported girder and a continuous girder respectively, were tested under simultaneous loading and fire exposure. The simply supported girder was exposed to fire over 40% of its span length in the middle zone, and the two-span continuous girder was exposed to fire over 38% of its length of the first span and full length of the second span. A measurement method based on comparative rate of deflection was provided to predict the failure time in the hogging moment zone of continuous composite box bridge girders under certain localized fire exposure condition. Parameters including transverse and longitudinal stiffeners and fire scenarios were introduced to investigate fire resistance of the composite box bridge girders. Test results show that failure of the simply supported girder is governed by the deflection limit state, whereas failure of the continuous girder occurs through bending buckling of the web and bottom slab in the hogging moment zone. Deflection based criterion may not be reliable in evaluating failure of continuous composite box bridge girder under certain fire exposure condition. The fire resistance (failure time) of the continuous girder is higher than that of the simply supported girder. Data from fire tests is successfully utilized to validate a finite element based numerical model for further investigating the response of composite box bridge girders exposed to localized fire. Results from numerical analysis show that fire resistance of composite box bridge girders can be highly influenced by the spacing of longitudinal stiffeners and fire severity. The continuous composite box bridge girder with closer longitudinal stiffeners has better fire resistance than the simply composite box bridge girder. It is concluded that the fire resistance of continuous composite box bridge girders can be significantly enhanced by preventing the hogging moment zone from exposure to fire. Longitudinal stiffeners with closer spacing can enhance fire resistance of composite box bridge girders. The increase of transverse stiffeners has no significant effect on fire resistance of composite box bridge girders.

A Study on the Improvement of Daily Inspection for the Safety of University Laboratory - Based on Delphi surney - (대학 연구실 안전을 위한 일상점검 개선방안에 관한 연구 - 델파이 조사를 기반으로 -)

  • Choi, Youn-Woo;Lee, yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.1
    • /
    • pp.38-48
    • /
    • 2019
  • The purpose of this study is to present a more effective daily checklist than the formal routine check before the experiment to prevent accidents in the university laboratory. To do this, we reconstructed the current daily checklist and previous research data and conducted a second Delphi survey. As a result, there were four general safeties such as arranging the laboratory, three mechanical safeties such as abnormal condition of machine and tool tightening parts, three electric safeties such as prohibition of loading around the electric distribution panel, six chemical safeties such as handling and managing harmful factors, three items of fire safety such as fire extinguisher inspection, five cases of gas safety gas container inspection, one item of biological safety such as the state of hand sterilizer management and one other item, which were provided in the daily checklist as twenty six categories in total. According to the opinions of related experts, it is necessary to have an easy and simplified daily checklist for actual daily checkups.

Effects of adenosine receptor agonist on the rocuronium-induced neuromuscular block and sugammadex-induced recovery

  • Kim, Yong Beom;Lee, Sangseok;Choi, Hey Ran;In, Junyong;Chang, Young Jin;Kim, Ha Jung;Ro, Young Jin;Yang, Hong-Seuk
    • Korean Journal of Anesthesiology
    • /
    • v.71 no.6
    • /
    • pp.476-482
    • /
    • 2018
  • Background: Several types of receptors are found at neuromuscular presynaptic membranes. Presynaptic inhibitory $A_1$ and facilitatory $A_{2A}$ receptors mediate different modulatory functions on acetylcholine release. This study investigated whether adenosine $A_1$ receptor agonist contributes to the first twitch tension (T1) of train-of-four (TOF) stimulation depression and TOF fade during rocuronium-induced neuromuscular blockade, and sugammadex-induced recovery. Methods: Phrenic nerve-diaphragm tissues were obtained from 30 adult Sprague-Dawley rats. Each tissue specimen was randomly allocated to either control group or 2-chloroadenosine (CADO, $10{\mu}M$) group. One hour of reaction time was allowed before initiating main experimental data collection. Loading and boost doses of rocuronium were sequentially administered until > 95% depression of the T1 was achieved. After confirming that there was no T1 twitch tension response, 15 min of resting time was allowed, after which sugammadex was administered. Recovery profiles (T1, TOF ratio [TOFR], and recovery index) were collected for 1 h and compared between groups. Results: There were statistically significant differences on amount of rocuronium (actually used during experiment), TOFR changes during concentration-response of rocuronium (P = 0.04), and recovery profiles (P < 0.01) of CADO group comparing with the control group. However, at the initial phase of this experiment, dose-response of rocuronium in each group demonstrated no statistically significant differences (P = 0.12). Conclusions: The adenosine $A_1$ receptor agonist (CADO) influenced the TOFR and the recovery profile. After activating adenosine receptor, sugammadex-induced recovery from rocuronium-induced neuromuscular block was delayed.

Reliability and Validity of an Electronic Inspiratory Loading Device for Assessing Pulmonary Function in Patients with COPD

  • Lee, Seugcheol;You, Seongkwang;Yang, Subin;Park, Daesung
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.1
    • /
    • pp.40-47
    • /
    • 2021
  • Objective: The purpose of this study is to prove the reliability and validity of the Power breath K5 and to compare it with pony FX. Power breathe K5 is one type of device can assess automatically Maximum inspiratory pressure (MIP), Peak inspiratory pressure, Peak inspiratory flow (PIF). Design: Cross-sectional study. Methods: Thirty-five COPD patients participated in the test to investigate for the intra relater reliability and concurrent validity. The tests MIP, Vital capacity (VC), PIF were measured by Powerbreathe K5 and Pony Fx. Data was analyzed by intraclass correlation reliability (ICC) value and a standard error of measurement and Bland-Altman plots for reliability and pearson correlation for validity. Results: Intra rater reliability of the Powerbreathe K5 was very high at MIP (ICC=0.977 95%CI 0.956~0.989, SEM=8.665, MDC=0.295), PIF (ICC=0.966 95%CI 0.933~0.93, SEM=8.665, MDC=0.295), VC (ICC=0.949 95CI 0.902~0.974, SEM=0.042, MDC=0.116). The Powerbreath K5 was significant correlation compared with Pony Fx in assessment for MIP (r=0.971, p<0.05) and vital capacity (r=0.534, p<0.05). Conclusion: In this study, We investigated the clinical usefulness of the Powerbreath K5 in evaulating the MIP, VC and PIF with COPD patients with high reliability and validity.