• Title/Summary/Keyword: Load-pull

Search Result 272, Processing Time 0.028 seconds

Numerical Analysis on Stress Distribution of Vertebra and Stability of Intervertebral Fusion Cage with Change of Spike Shape (척추체간 유합케이지의 스파이크형상 변화에 따른 척추체의 응력분포 및 케이지의 안정성에 대한 수치적 해석)

  • 심해영;김철생;오재윤
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.361-367
    • /
    • 2004
  • The axial compressive strength, relative 3-D stability and osteoconductive shape design of an intervertebral fusion cage are important biomechanical factors for successful intervertebral fusion. Changes in the stress distribution of the vertebral end plate and in cage stability due to changes in the spike shape of a newly contrived box-shaped fusion cage are investigated. In this investigation, the initial contact of the cage's spikes with the end plate and the penetration of the cage's spikes into the end plate are considered. The finite element analysis is conducted to study the effects of the cage's spike height, tip width and angle on the stress distribution of the vertebral end plate, and the micromigration of the cage in the A-P direction. The stress distribution in the end plate is examined when a normal load of 1700N is applied to the vertebra after inserting 2 cages. The micromigration of the cage is examined when a pull out load of l00N is applied in the A-P direction. The analysis results reveal that the spike tip width significantly influences the stress concentration in the end plate, but the spike height and angle do not significantly influence the stress distribution in the end plate touching the cage's spikes. In addition, the analysis results show that the micromigration of the cage can be reduced by adjusting the spike angle and spike arrangement in the A-P direction. This study proposes the optimal shape of an intervertebral fusion cage, which promotes bone fusion, reduces the stress concentration in a vertebral end plate, and increases mechanical stability.

Pulse Density Modulation Controlled Series Load Resonant Zero Current Soft Switching High Frequency Inverter for Induction-Heated Fixing Roller

  • Sugimura, Hisayuki;Kang, Ju-Sung;Saha, Bishwajit;Lee, Hyun-Woo;Nakaoka, Mutsuo
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.226-228
    • /
    • 2006
  • This paper presents the two lossless auxiliary inducors-assisted voltage source type half bridge(single ended push pull:SEPP) series resonant high frequency inverter for induction heated fixing roller in copy and printing machines. The simple high-frequency inverter treated here can completely achieve stable zero current soft switching (ZCS) commutation forwide its output power regulation ranges and load variations under constant high frequency pulse density modulation (PDM) scheme. Its transient and steady state operatprinciple is originally described and discussed for a constant high-frequency PDM control strategy under a stable ZCS operation commutation, together with its output effective power regulation charactertics-based on the high frequency PDM strategy. The experimenoperating performances of this voltage source SEPP ZCS-PDM series resonant high frequency inverter using IGBTs are illustrated as compared with computer simulation results and experimenones. Its power losses analysis and actual efficiency are evaluated and discussed on the basis of simulation and experimental results. The feasible effectiveness of this high frequency inverter appliimplemented here is proved from the practical point of view.

  • PDF

Realization of High Linear and Efficiency Power Amplifier Using Optimum Load Without Hybrid Coupler (Hybrid Coupler 제거와 부하 최적화를 이용한 고효율 및 고선형성 전력 증폭기의 관한 연구)

  • An, Se-Hwan;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.2 s.344
    • /
    • pp.88-93
    • /
    • 2006
  • In this paper, smaller load has been used compared with the conventional Doherty amplifier and PBG structure have been employed to suppress IMD (Inter-modulation Distortion) and improve PAE (Power Added Efficiency). And The PBG structure has been employed on the output macthing network of Doherty amplifier. The proposed power amplifier has been improved more the IMD3 by 5.5 dBc, and the average PAE by $5\%,$ at peak output power, $18\%$ at 8dB back-off point respectively than the conventional Doherty power amplifier.

Investigation of the Rotational Displacement of the Suction Anchor Subjected to the Inclined Pullout Load in Silty Sand (사질토 지반에서 경사 인발 하중을 받는 석션 앵커의 회전 거동 평가)

  • Bae, Jun-Sik;Jeong, Yeong-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.267-273
    • /
    • 2020
  • Suction anchors are used for floating structures because they have advantages in installation and stability. Recently, the demand for floating structures requiring low allowable displacement has increased. Thus, it is strongly suggested that the displacement of the suction anchor be evaluated. However, conventional studies regarding suction anchors have concentrated on the capacity of the anchor, and research on the displacement of the anchor is limited. In particular, rotation is the primary behavior of a suction anchor subjected to an inclined load, and related information has been insufficient. Therefore, the main objective of this paper is to investigate the rotation behavior of a suction anchor via centrifuge model tests. The experimental parameters are the inclination of the pull-out load, anchor dimensions, and aspect ratio. The rotation values of suction anchors were compared using a series of load-rotation curves. The results show that the inclination of the load has a dominant influence on the rotation behavior of the suction anchor.

Influence of varying cement types and abutment heights on pull-off force of zirconia restorations (시멘트의 종류 및 임플란트 지대주 높이가 지르코니아 수복물의 제거력에 미치는 영향)

  • Yeong-Jun Jung;Yu-Lee Kim;Ji-Hye Jung;Nae-Un Kang;Hyun-Jun Kong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.64-71
    • /
    • 2024
  • Purpose: The purpose of this study is to evaluate Ti-base abutment's three different heights and three different cement types on the pull-off force of zirconia-based restorations. Materials and Methods: A total of 90 fixture lab analogs were embedded in auto polymerizing resin bloack. 90 Ti-base abutments heights of 3 mm, 5 mm, 7 mm were scanned and zirconia restoration were prepared from scanned files. Zirconia restoration were cemented with three different types of cements (temporary, semi-permanent, permanent) following manufacturer's instructions. All 90 specimens were placed and tested in a universal testing machine for pull-out testing. Retention was measured by recording the force at load drop. Statistical analysis was performed using Kruskal-Wallis test for detecting whether there are any statistical significance along cement types or abutment heights. After that, Mann-Whitney test was used for figuring out differences regarding abutment height and the comparison between 3 cements. Results: Temp bond showed significantly lower pull-off force compared to Fujicem regardless of any abutment height. However, there were significant differences between Cem-implant and Fujicem in abutment height of 3 mm and 7 mm, but there was no significant difference in 5 mm. Temp bond and Cem-implant had significant differences only in abutment height of 5 mm. Conclusion: Although Ti-base abutment height did not influenced zirconia restorations' retentiveness, cement types showed significant differences.

Investigation of the Crop Load for Tomato and Paprika in the Greenhouse (온실내 재배작물인 토마토 및 파프리카의 작물하중 검토)

  • Choi, Man Kwon;Yun, Sung Wook;Yu, Chan;Lee, Si Young;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.234-240
    • /
    • 2013
  • The purpose of this study was to provide basic data used in greenhouse design, and for this purpose, the crop loads of tomato and paprika which have high crop load among crops cultivated in greenhouse were measured. The maximum differences in lowest and mean temperatures between cultivation year and normal years for winter season were -5.6 and $-4.9^{\circ}C$, respectively and those for summer season were 3.0 and $1.5^{\circ}C$, respectively. The calibration of push & pull gauge indicated approximate 0.99 of coefficient of determination, representing very high association. The planting densities of paprika and tomato were 3.43, 3.56 and $2.13plants{\cdot}m^{-2}$, respectively. The yields were 4.1, 4.3 and $16.2kg{\cdot}plant^{-1}$, corresponding to 14.1, 15.2 and $34.5kg{\cdot}m^{-2}$ of yield per unit area. The maximum loads were 1.3, 1.5 and $3.3kg{\cdot}plant^{-1}$, respectively. When the paprika were hanged on cross beam, the total crop load applied to it was estimated to be $15.3{\sim}15.9kg{\cdot}m^{-2}$, and when the weights of gutters supporting the cultivation beds, the total weights were $26.0{\sim}26.9kg{\cdot}m^{-2}$.

2MHz, 2kW RF Generator (2MHz, 2kW RF 전원장치)

  • Lee J.H.;Choi D.K.;Choi S.D.;Choi H.Y.;Won C,Y.;Kim S.S
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.260-263
    • /
    • 2003
  • When ICP(Inductive Coupled Plasma type etching and wafer manufacturing is being processed in semiconductor process, a noxious gas in PFC and CFC system is generated. Gas cleaning dry scrubber is to remove this noxious gas. This paper describes a power source device, 2MHz switching frequency class 2kW RF Generator, used as a main power source of the gas cleaning dry scrubber. The power stage of DC/DC converter is consist of full bridge type converter with 100kHz switching frequency Power amplifier is push pull type inverter with 2MHz switching frequency, and transmission line transformer. The adequacy of the circuit type and the reliability of generating plasma in various load conditions are verified through 50$\Omega$ dummy load and chamber experiments result.

  • PDF

Construction and Functional Tests of Fuel Assembly Mechanical Characterization Test Facility (핵연료집합체 기계적특성 시험시설 구축과 기능시험)

  • Lee, Kang-Hee;Kang, Heung-Seok;Yoon, Kyung-Ho;Yang, Jae-Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2016
  • Fuel assembly's mechanical characterization test facility (FAMeCT) in KAERI was constructed with upgraded functional features such as increased loading capacity, underwater vibration testing and severe earthquake simulation for extended fuel design guideline. This facility is designed and developed to provide out-pile fuel data for accident analysis model and fuel licensing. Functional tests of FAMeCT were performed to confirm functionality, structural integrity, and validity of newly-built fuel assembly mechanical test facility. Test program includes signal check of data acquisition system, load delivering capacity using real-sized fuel assemblies and a standard loading cylindrical rigid specimen. Fuel assembly's lateral bending test was carried out up to 30 mm of pull-out displacement. Limit case axial compression loading test up to 33 kN was performed to check structural integrity of UCPS (Upper Core Plate Simulator) support frame. Test results show that all test equipment and measurement system have acceptable range of alignment, signal to noise ratio, load carrying capacity limit without loss of integrity. This paper introduces newly constructed fuel assembly's mechanical test facility and summarizes results of functional test for the mechanical test equipment and data acquisition system.

Strength of Anchors under Load Applied Angles (앵커볼트의 내력평가에 관한 실험적 연구)

  • Kim, Sung-Yong;Han, Duck-Jeon;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.1 s.16
    • /
    • pp.69-76
    • /
    • 2005
  • The pull-out capacity of expansion anchor(heavy duty anchor and wedge anchor) was studied experimentally in this paper. Loading conditions included tension, shear, and combined tension and shear. The heavy duty anchor and wedge anchor were manufactured in domestic and installed In plain concrete. The failure mode of steel and concrete were studied carefully for the analytical formula of the anchorage design and the experimental data were compared with different models for the interaction of tension and shear capacities. Based on the research, the following conclusion may be drawn : The interaction of forces is well-described by an elliptical interaction relationship.

Design and Fabrication of the Frequency Doubler for 24GHz Local Oscillator (24GHz 대역 국부발진기용 주파수 체배기 설계 및 제작)

  • Seo, Gon;Kim, Jang-Gu;Han, Sok-Kyun;Park, Chang-Hyun;Choi, Byung-Hai
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.411-415
    • /
    • 2003
  • In this paper, a reflector type frequency doubler for local oscillator at 24GHz is designed and fabricated with ne71300-N MESFET. Optimum source and load impedances are decided through a multiharmonic load pull simulation technique. A conversion gain ran be improved using the reflector and fundamental and third harmonics are well suppressed with open stub of λ/4 length. Measured results show output power at 0dBm of input power is -3.776dBm, conversion gain 0.736dB, harmonic suppression 41.064dBc, respectively.

  • PDF