자유유동 난류강도가 터빈 동익 표면에서의 열(물질)전달 특성에 미치는 영향 (Free-Stream Turbulence Effect on the Heat (Mass) Transfer Characteristics on a Turbine Rotor Surface)

  • 이상우;박진재;권현구;박병규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1442-1446
    • /
    • 2004
  • The heat (mass) transfer characteristics on the blade surface of a first-stage turbine rotor cascade has been investigated by employing the naphthalene sublimation technique. A four-axis profile measurement system is employed for the measurements of the local heat (mass) transfer coefficient on the curved blade surface. The experiments are carried out for two free-stream turbulence intensities of 1.2% and 14.7%. The high free-stream turbulence results in more uniform distributions of heat load on the both pressure and suction surfaces and in an early boundary-layer separation on the suction surface. The heat (mass) transfer enhancement on the suction surface due to the endwall vortices is found to be relatively small under the high free-stream turbulence.

  • PDF

청과물저장고의 구조특성 및 냉각부하량 산정에 관한 연구 (A Study on the Structural Characteristics and Estimation of Refrigerating. Load for the Fruit Storage)

  • 이석건;고재군
    • 한국농공학회지
    • /
    • 제18권1호
    • /
    • pp.4038-4051
    • /
    • 1976
  • This study was intended to provide the basic design creteria for the refrigerated storage, and to estimate the required optimum capacity of refrigerator for the different sizes and kinds of the existing fruit storage. The structural characteristics of the existing fruit storages in Pyungtaek-khun of Kyungki-do were surveyed. The average out-door air temperature during the expected storage life after harvesting, was obtained by analyzing the weather information. The heat transfer rates through the different models of storage walls were estimated. The refrigerating load required for different models of fruit storage was analyzed in the basis of out-door air temperature. The results obtained in this study are summarized as follows: 1. The fruit storages surveyed were constructed on-ground, under-ground and sub-ground type buildings. The majority of them being the on-ground buildings are mostly made of earth bricks with double walls. Rice hull was mostly used as the insulating materials for their walls and ceilings. About 42% of the buildings were with the horizontal ceiling, 22% with sloped ceiling, and about 36% without ceiling. About 60% of the storage buildings had floor without using insulated material. They were made of compacted earth. 2. There is no difference in heat transfer among six different types of double walls. The double wall, however, gives much less heat transfer than the single wall. Therefore, the double wall is recommended as the walls of the fruit storage on the point of heat transfer. Especially, in case of the single wall using concrete, the heat transfer is about five time of the double walls. It is evident that concrete is not proper wall material for the fruit storage without using special insulating material. 3. The heat transfer through the storage walls is in inverse proportion to the thickness of rice hull which is mostly used as the insulating material in the surveyed area. It is recommended that the thickness of rice hull used as the insulating material far storage wall is about 20cm in consideration of the decreasing rate of heat transfer and the available storage area. 4. The design refrigerating load for the on-ground storages having 20 pyung area is estimated in 4.07 to 4.16 ton refrigeration for double walls, and 5.23 to 6.97 ton refrigeration for single walls. During the long storage life, however, the average daily refrigerating load is ranged from 0.93 to 0.95 ton refrigeration for double walls, and from 1.15 to 1.47 ton refrigeration for single walls, respectively. 5. In case of single walls, 50.8 to 61.4 percent to total refrigerating load during the long storage life is caused by the heat transferred into the room space through walls, ceiling and floor. On the other hand, 39.1 to 40.7 percent is for the double walls. 6. The design and average daily refrigerating load increases in linear proportion to the size of storage area. As the size increases, the increasing rate of the refrigerating load is raised in proportion to the heat transfer rate of the wall. 7. The refrigerating load during the long storage life has close relationship to the out-door air temperature. The maximum refrigeration load is shown in later May, which is amounted to about 50 percent to the design refrigerating load. 8. It is noted that when the wall material having high heat transfer rate, such as the single wall made of concrete, is used, heating facilities are required for the period of later December to early February.

  • PDF

냉각된 복사천장패널의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling)

  • 이태원;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF

환경 정보를 이용한 상용차량 전복 방지 알고리즘 개발 (Development of Roll Stability Control of Commercial Vehicles with Environment Information)

  • 박동우;허현동;이경수
    • 자동차안전학회지
    • /
    • 제5권1호
    • /
    • pp.50-55
    • /
    • 2013
  • When it comes to commercial vehicles, their unique characteristics - center of gravity, size, weight distribution - make them particularly vulnerable to rollover. On top of that, conventional heavy vehicle brake exhibits longer actuation delays caused in part by long air lines from brake pedal to tires. This paper describes rollover prevention algorithm that copes with the characteristics of commercial vehicles. In regard of compensating for high actuating delay, predicted rollover index with short preview time has been designed. Moreover, predicted rollover index with longer preview time has been calculated by using road curvature information based on environment information. When rollover index becomes larger than specific threshold value, desired braking force is calculated in order to decrease the index. At the same time, braking force is distributed to each tire to make yaw rate track desired value.

알루미늄 나선형 와이어로 직조된 다층 Kagome Truss PCM의 유동 및 열전달 특성에 관한 연구 (A Study on the Fluid Flow and Heat Transfer Characteristics for the Wire-woven Bulk Kagome(WBK) Composed of Aluminum Helix Wires)

  • 주재황;강보선;강기주
    • 대한기계학회논문집B
    • /
    • 제32권1호
    • /
    • pp.15-22
    • /
    • 2008
  • Recently, ultra-lightweight materials with open, periodic cell structures take much attention owing to its potential for multi-functionality such as load bearing, thermal dissipation, and actuation. This paper presents experimental results on the fluid flow and heat transfer characteristics for the Wire-woven Bulk Kagome (WBK) composed of aluminum 1100 wires. The overall pressure drop and heat transfer of the WBK specimen was experimentally investigated under forced air convection condition. The pressure loss and heat transfer performance of the aluminum WBK were compared with other heat dissipation media. It was shown that heat transfer characteristics depended on relative density and surface area density. Comparison with metal foams and other heat dissipation media such as packed beds, lattice frame materials, louvered fins, and others suggests that the aluminum WBK competes favorably with the best available heat dissipation media in heat transfer performance.

An Experimental Study of Valve Seat Material Galling Characteristics in Waterworks

  • Park, Sung-Jun;Kim, Young-Tae;Lee, Sang-Jo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권1호
    • /
    • pp.46-51
    • /
    • 2007
  • Environmental contamination creates shortages of potable water. In such situations, the leakage of water due to breakage or aging of rubber valve seats is a serious problem. Rubber is apt to break when it is placed between two materials that contact each other. One way to avoid water leakage due to rubber damage and breakdown is to replace the rubber with metal, which is currently taking place in water distribution systems. In tribology, a severe form of wear is characterized by local macroscopic material transfer or removal, or by problems with sliding protrusions when two solid surfaces experience relative sliding under load. One of the major problems when metal slides is the occurrence of galling. Experimentally, various conditions influence incipient galling, such as hardness, surface roughness, temperature, load, velocity, and the external environment. This study sought to verify the galling tendencies of metal according to its hardness, surface roughness, load, and sliding velocity, and determine the quantitative effect of each factor on the galling tendencies.

부하 임피던스 변화에 따른 6.78MHz 전류모드 D급 전력증폭기 특성 해석 (Performance Analysis of 6.78MHz Current Mode Class D Power Amplifier According to Load Impedance Variation)

  • 고석현;박대길;구경헌
    • 한국항행학회논문지
    • /
    • 제23권2호
    • /
    • pp.166-171
    • /
    • 2019
  • 본 논문은 6.78 MHz무선전력전송 송신기의 전송 효율을 높이고 송수신 코일 간격 변화에도 안정적 특성을 확보하기 위해 전류 모드 클래스 D 전력증폭기를 설계한다. 선형증폭기의 이론적인 효율을 제한하는 트랜지스터의 기생 커패시터 성분에 의한 손실을 적게 만들어 전력증폭기의 효율을 향상시킨다. 회로 설계 시뮬레이터를 이용하여 고효율 증폭기를 설계하고 부하 임피던스 변화에 따른 전력 출력, 효율 특성을 시뮬레이션하여 검증하였다. 시뮬레이션에서 DC 바이어스 30 V일 때 42.1 dBm의 출력과 95%의 효율을 갖도록 설계하였다. 전력증폭기를 제작하여 42.1 dBm (16 W)의 출력에서 91%의 효율을 보였다. 드론 무선전력전송에 적용될 송수신 코일을 제작하였으며, 송수신 코일 간격에 따른 부하변화에 따라 전력부가효율이 최대 88% 이고 출력전력 $42.1dBm{\pm}1.7dB$의 특성을 나타내었다.

양방향 재하시험결과를 활용한 바렛말뚝의 하중전이특성 평가 (Evaluation of Load Transfer Characteristics of Barrette Pile Based on Bi-directional Loading Tests)

  • 박성완;임대성
    • 대한토목학회논문집
    • /
    • 제29권2C호
    • /
    • pp.41-49
    • /
    • 2009
  • 구조물의 대형화와 재료비의 증가로 인해 다수의 기성말뚝을 대체할 수 있는 대형 현장타설말뚝의 사용이 증가하고 있다. 특히, 지하연속벽공법이 적용된 현장의 기초시공에 따른 시공성 및 경제성을 향상시키거나 토사층이 깊게 분포한 경우 공벽의 안정성을 확보하기 위한 기초형식으로 바렛말뚝의 사용이 증가하고 있는 실정이다. 본 논문에서는 국내 4개 현장을 대상으로 바렛말뚝을 시공하고 양방향 재하시험을 실시하여 말뚝의 지지력 및 침하특성을 고찰하였다. 또한 하중전이분석을 통하여 주면마찰력의 평가를 위한 ${\beta}$값을 분석하여 비교 평가하였고 3차원 유한요소해석을 통하여 양방향재하시험에 따른 경계면 효과와 하중-침하특성을 살펴보았다.