• 제목/요약/키워드: Load sensor signal

검색결과 129건 처리시간 0.031초

표면 탄성파 장치를 응용한 용량 성 변위센서의 설계 및 초정밀 간극 측정 (Design of Capacitive Displacement Sensor and Gap Measurement with High Precision Using Surface Acoustic Wave Device)

  • 김재근;이택주;임수철;박노철;박영필;박경수
    • 한국소음진동공학회논문집
    • /
    • 제20권5호
    • /
    • pp.437-443
    • /
    • 2010
  • SAW device is widely used as band pass filters, chemical or physical sensors, and actuators. In this paper, we propose the capacitive gap measurement system with high precision using SAW device. The research process is mainly composed of theoretical and experimental part. In the theoretical part, equivalent circuit model was used to predict the SAW response by the change of load impedance. In the experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance to check the feasibility as a sensor unit. After that, experimental setup to measure and adjust the gap was made and the SAW response by the change of gap which caused the capacitance change was measured. Finally, resolution and stroke was decided compared with the signal change and basic measurement noise level.

마이크로프로세서를 이용한 병원용 환자 링거액 잔류유량 원격 실시간 검사 시스템 개발 (Development of a Remote Monitoring System of the Residual Amount of Ringer's Solution at Hospitals Using a Microprocessor)

  • 하관용;권종원;오드게렐;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.279-282
    • /
    • 2005
  • A real-time measurement and control system was developed, This system is used for nurses at hospitals to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution, This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by NO converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

요속검사시 배뇨상황에 무관한 신호대잡음비 개선 기법 (Enhancement of signal-to-noise ratio for uroflowmetric test regardless of urination situation)

  • 김경아;최성수;이상봉;김경옥;박경순;신은영;김원재;차은종
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.423-431
    • /
    • 2009
  • Standard uroflowmetry measures the urine weight using single load cell to evaluate the urinary flow rate. Impact noise should be introduced due to gravity when the urine stream falls down into the container upon the load cell. The present study placed three load cells on the three vertices of a regular triangle and the three signals were ensemble averaged to enhance the signal-to-noise ratio(SNR) regardless of how the urination was made. Simulated urination experiment was performed with three different urine collection methods. In all three methods, SNR of the averaged signal was much higher than each load cell signals. With no urine collection device, the present signal averaging technique resulted in SNR values higher by 10~15 dB than when dual funnels or upper funnel were used to guide the urine stream. Therefore, it was demonstrated that the three point measurement followed by with ensemble averaging could enable accurate uroflowmetric test without any specially made urine collection devices.

ART2 Neural Network Applications for Diagnosis of Sensor Fault in the Indoor Gas Monitoring System

  • Lee, In-Soo;Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1727-1731
    • /
    • 2004
  • We propose an ART2 neural network-based fault diagnosis method to diagnose of sensor in the gas monitoring system. In the proposed method, using thermal modulation of operating temperature of sensor, the signal patterns are extracted from the voltage of load resistance. Also, fault classifier by ART2 NN (adaptive resonance theory 2 neural network) with uneven vigilance parameters is used for fault isolation. The performances of the proposed fault diagnosis method are shown by simulation results using real data obtained from the gas monitoring system.

  • PDF

광섬유 센서를 이용한 섬유-금속 적층판의 손상 감지 (Damage Detection of Fiber-Metal Laminates Using Optical Fiber Sensors)

  • 양유창;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 추계학술발표대회 논문집
    • /
    • pp.161-164
    • /
    • 2002
  • Optical fiber vibrations sensors (OFVSs) and extrinsic Fabry-Perot interferometer (EFPI) were used in damage monitoring of fiber-metal laminates(FML). The optical fiber vibration sensor and EFPI were applied in order to detect and evaluate the strain, damage and failure of FML. Damages in composites, such as matrix cracks, delamination and fiber breakage may occur as a result of excessive load, fatigue and low-velocity impacts. Tensile test was performed with the measurement of optical signal and acoustic emission (AE). The signals of the optical fiber vibration sensor due to damages were quantitatively evaluated by wavelet transform. EFPI was less sensible to the damage signals compared with the optical fiber vibration sensor. It was found that damage information of comparable in quality to acoustic emission data could be obtained from the optical fiber vibration sensor signals.

  • PDF

압력센서의 배선을 위한 다층 박막의 지지조건 변화에 따른 잔류응력 평가 (Evaluation of the Residual Stress with respect to Supporting Type of Multi-layer Thin Film for the Metallization of Pressure Sensor)

  • 심재준;한근조;김태형;한동섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1537-1540
    • /
    • 2003
  • MEMS technology with micro scale is complete system utilized as the sensor. micro electro device. The metallization of MEMS is very important to transfer the power operating the sensor and signal induced from sensor part. But in the MEMS structures local stress concentration and deformation is often happened by geometrical shape and different constraint on the metallization. Therefore. this paper studies the effect of supporting type and thickness ratio about thin film thickness of the substrate thickness for the residual stress variation caused by thermal load in the multi-layer thin film. Specimens were made from materials such as Al, Au and Cu and uniform thermal load was applied, repeatedly. The residual stress was measured by FEA and nano-indentation using AFM. Generally, the specimen made of Al induced the large residual stress and the 1st layer made of Al reduced the residual stress about half percent than 2nd layer. Specimen made of Cu and Au being the lower thermal expansion coefficient induce the minimum residual stress. Similarly the lowest indentation length was measured in the Au_Cu specimen by nano-indentation.

  • PDF

근 부피 센서를 이용한 인체 팔꿈치 관절의 동작 토크 추정 (Torque Estimation of the Human Elbow Joint using the MVS (Muscle Volume Sensor))

  • 이희돈;임동환;김완수;한정수;한창수;안재용
    • 한국정밀공학회지
    • /
    • 제30권6호
    • /
    • pp.650-657
    • /
    • 2013
  • This study uses a muscle activation sensor and elbow joint model to develop an estimation algorithm for human elbow joint torque for use in a human-robot interface. A modular-type MVS (Muscle Volume Sensor) and calibration algorithm are developed to measure the muscle activation signal, which is represented through the normalization of the calibrated signal of the MVS. A Hill-type model is applied to the muscle activation signal and the kinematic model of the muscle can be used to estimate the joint torques. Experiments were performed to evaluate the performance of the proposed algorithm by isotonic contraction motion using the KIN-COM$^{(R)}$ equipment at 5, 10, and 15Nm. The algorithm and its feasibility for use as a human-robot interface are verified by comparing the joint load condition and the torque estimated by the algorithm.

고압전동기용 진동 감시 시스템을 위한 특징 파라미터 추출기법 개발 (Development of the Extracting Technique of the Character Parameter for the Vibration Monitoring System in High Voltage Motor)

  • 이달호;박정철
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권4호
    • /
    • pp.349-358
    • /
    • 2019
  • 본 논문에서는 회전체의 특징 파라미터들을 추출하기 위한 센서의 신호들을 수집하는 방법을 연구하고자 한다. 이를 위해, 모형 시험을 수행하기 위한 진동 테스트 리그를 개발하여 정상적으로 운전하에서의 신호특성을 분석하였다. 다른 진동 요소들로부터 주기적인 충격에 의해 발생되는 진동 성분을 추출하기 위하여 포락 신호처리(Envelope FFT Analysis) 기법을 사용하였다. 회전속도에 따른 신호분석과 더불어 회전체의 저주파수 특성을 잘 나타내는 속도센서 및 진동 테스트 리그의 부하변화에 따른 신호를 분석하였다. 그 결과, 베어링 하우징에서 측정되는 가속도 신호는 진폭이 작으며 조화 성분과 모터의 회전주파수 성분만이 발생함을 확인하였다. 즉, 회전수가 높아짐에 따라 가속도의 진폭이 높아짐을 확인할 수 있었다. 회전속도가 증가하면 원 데이터의 형상의 차이가 있는 것을 확인할 수 있었고, 가속도 FFT 그래프와 비교하였을 경우 저 주파수에서 노이즈에 강하며 해당 회전 주파수 성분을 뚜렷하게 나타내었다. 또한 부하를 변화시켜도 주요 회전 주파수 성분이 증가하지 않음을 알 수 있었다.

Development of a Foot Pressure Distribution Measuring Device for Lower Limb Rehabilitaion

  • Choi, Junghyeon;Seo, Jaeyong;Park, Jun Mo
    • 융합신호처리학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-5
    • /
    • 2017
  • It is important to train lower limb muscle strength using a tilting table to recover the lower extremity function of hemiplegia patients. It is known that the foot deformity and poor posture of hemiplegia patients can reduce the effectiveness of lower limb rehabilitation training. In this study, we developed a sensor system that can measure the foot pressure distribution of the patients for the load control of the lower extremity during lower limb rehabilitation training and it can be substituted for conventional high-cost technologies.

  • PDF

마이크로프로세서를 이용한 인터넷기반 전력관리시스템 개발에 관한 연구 (A Study on Development of Internet Based Power Management System Using a Microprocessor)

  • 천행춘
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.746-753
    • /
    • 2004
  • In this paper, the Power Management System(PMS) which based on a decision making system according to power strategy is proposed and implemented. PMS is designed to have functions of power monitoring. controlling, synchronizing load sharing and monitoring of driving engine, etc. PMS consists of the internet communication system(ICS). Remote Management System(RMS) and Sensor Driver System (SDS) ICS transmits the monitoring and supervisory data via Internet to Remote Management System(RMS) in real-time SDS detects various power system data on local generator and utility via I/O interface system. I/O interface system receives various status data and outputs control signals. Implemented PMS is tested with dummy signal to verify proposed functions and shows good results. For future study implemented PMS will be tested under real load condition to merchandize.