• 제목/요약/키워드: Load power factor

검색결과 847건 처리시간 0.031초

25KJ 초전도 에너지 저장장치의 설계,제작 및 특성 시험 (A Study on the Design, Fabrication and Characteristics Test of 25KJ Superconducting Magnetic Energy Storage)

  • 홍원표;원종수;이송엽;이승원
    • 대한전기학회논문지
    • /
    • 제37권10호
    • /
    • pp.683-693
    • /
    • 1988
  • For the economical and reasonable operation of electric power system according to continual increase of electric power demand and decrease of load factor, the potential application of superconducting magnertic energy storage [SMES] with high efficiency and fast response in the electric utility is receiving attractive attension. In the light of this background, to confirm the basic principle of SMES, theoretical study, design technique and fabrication procedure for superconducting coil, current lead, cryostat, measuring and protection system of SMES are described in detail. Especially, a new design technique for superconducting coil and current lead is porposed and it was proved experimentally by the performance test of SMES which is developed for the first time in our country. At the peak operating current 200A, the maximum magnetic field amd stored energy of the coil are 3.52T and 2500J, espectively. The thermal and mechanical stability of 2500J SMES is also confirmed experimetally by its characteristics test, AC loss, protection system, charge and discharge test. The experimetal results show good characteristics of energy storage system.

  • PDF

새로운 선로사고분배계수 알고리즘을 이용한 과부하 해소대책 (An Overload Alleviation Countermeasure using New Line Outage Distribution Factor)

  • 박규홍;정재길;강동구;김정하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.588-590
    • /
    • 1995
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads in a power system. This method utilizes network sensitivity factors which are establised from DC load flow solutions. The line outage distribution factors(LODF) are formulated using changes in network power generations to simulate the outaged line from the network. The proposed algorithm has been validated in tests on a 6-bus test system.

  • PDF

부하전류와 듀티를 보상하는 단상 PFC 부스트 컨버터 제어기 설계 (A Study of Design single phase Boost Converter Controller for Compensated Load Current and Duty)

  • 임재욱;이승태;백승우;김학원;조관열
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.160-161
    • /
    • 2017
  • 기존의 단상 PFC(Power Factor Correction) 부스트 컨버터의 제어기는 부하전류와 듀티를 고려하지 않아 부하 변동시 출력전압을 일정하게 유지할 수 없다. 본 논문에서는 부하전류와 듀티를 보상하는 단상 PFC 부스트 컨버터 전압제어기 설계 방법을 제안한다. 인덕터 전류와 캐패시터 전류의 관계를 해석하여 제어기를 설계하고 모의 해석을 통해 입증한다.

  • PDF

LC공진에 의한 단상 PFC정류회로의 연구 (A Study of Single-Phase PFC Rectifier Circuit by LC Resonance)

  • 이상현;박진민;김영문;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1235-1237
    • /
    • 2003
  • For small capacity rectifier circuits as these for consumer electronics and appli capacitor input type rectifier circuits are gen used. Consequently. various harmonics gen within the power system become a serious pro Various studies of this effect have been pres previously. However. most of these employ swit devices, such as FETs and the like. The absen switching devices makes systems more toleran over -load, and brings low radio noise benefits propose a power factor correction scheme using resonant in commercial frequency without swit devices. In this method. It makes a sinusoidal by widening conduction period using the cu resonance in commercial frequency. Hence, harmonic characteristics can be significantly imp where the lower order harmonics. such as the and seventh orders are much reduced. The resu confirmed by the theoretical and experm implementations.

  • PDF

3상 AC/DC/AC PWM 컨버터의 직류링크 리플전류 해석 (Analysis of DC Link Ripple Currents in Three-Phase AC/DC/AC PWM Converters)

  • 박영욱;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.223-226
    • /
    • 2001
  • In this paper, dc link ripple currents for three-phase ac/dc/ac PWM converters are analyzed in a frequency domain. The expression of the harmonic currents is developed by using switching functions and exponential Fourier series expansion. The dc link ripple currents with regard to power factor and modulation index are investigated. In addition, the effect of the displacement angle between the switching periods of line-side converters and load-side inverters on the do link ripple current is studied. The result of the do link current analysis is helpful in specifying the dc link capacitor size and its life time estimation.

  • PDF

입력전류 파형 개선형 단상 정류기의 토폴로지 (Topology of input current waveform improvement type single-phase rectifier)

  • 이상현;박진민;문상필;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.403-406
    • /
    • 2003
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FET and the like. The absence of switching devices mattes systems more tolerant to over-load and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced The result are confirmed by the theoretical and experimental implementations.

  • PDF

다중화 전압원 인버어터를 이용한 무효전력 보상장치(SVC)에 관한 연구 (A Study on Static Var Compensator Using Multi Voltage Source Inverter)

  • 모창호;김홍규;강석구;김영민;박현철;유철로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.403-406
    • /
    • 1995
  • In general, the reactive power is controlled by amplitude of the output voltage. This paper propose that the multiple voltage source inverter have controllable power factor made by load vary at receive-stage as lagging and leakage control.

  • PDF

계통 연계 PV-ESS 확장성 확보를 위한 병렬 DC-모듈형 PCS 설계 (The bidirectional DC module type PCS design for the System Inter Connection PV-ESS of Secure to Expandability)

  • 황락훈;나승권;최병상
    • 한국정보전자통신기술학회논문지
    • /
    • 제14권1호
    • /
    • pp.56-69
    • /
    • 2021
  • 상용계통과 연계한 PV 시스템은 인버터의 특성과 더불어 소형, 고 역률, 낮은 고조파 출력, 고 신뢰성, 최대출력 운전, 저비용 등의 장점이 요구된다. 태양광발전시스템의 PV 에너지를 계통과 부하로 전달하기 위해 양방향의 PCS가 요구되어 진다. 본 논문에서는 태양광 발전의 ESS를 고려한 PCS를 제안하여 부하평준화를 통한 전력의 안정적인 공급을 확인하고자 한다. 이를 위해 일사량과 부하량에 따른 5단계의 동작 모드 알고리즘을 제안하고, 충/방전 제어를 위한 제어기를 설계 하였다. 양방향의 효율적인 에너지 전달을 위해 DC-link단에 양방향 컨버터 및 배터리를 연결하고, 연계형 인버터를 통해 DC-link 전압 및 인버터 출력전압을 제어하였다. 제안된 시스템의 타당성을 입증하기 위해 PSIM을 사용한 시뮬레이션을 수행하여 타당성과 안정성을 검토하였으며, 이를 확인하기 위해 3[kW] PCS를 제작하여 실험하였다. 실험결과를 통해 제안된 시스템에 요구되어지는 특성을 검증하였으며 기존 시스템에 비해 강인한 시스템을 구성하였다.

태양광발전 저압연계시 인버터 출력단 전압상승에 대한 연구 (A study on the voltage rise of the inverter output terminal according to the low voltage Grid connection of solar power generation)

  • 조강연;어익수
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.746-752
    • /
    • 2020
  • 환경문제가 세계적으로 심각하게 다뤄지면서 우리나라도 태양광발전 설비가 급속도로 증가하였다. 특히 소용량 태양광발전을 저압배전으로 연계하는 계통에서 인버터 출력단의 전압상승으로 인하여 저압배전계통 품질저하 및 부하설비에 악영향을 주고 있다. 또한 과전압에 의한 인버터 가동중지로 인하여 발전소의 경제적 손실을 줄 수 있다. 본 논문에서는 저압배전계통 연계에 따른 태양광 인버터 출력단 전압 상승 해결방안을 연구 하였다. 첫째, 역률제어 및 능동전압제어 인버터를 사용하여 무효전력을 제어하면 출력단 전압이 230.91V에서 208.99V로 단자전압 비율이 약 10%가 내려갔다. 둘째, 배전전압용 변압기 2차 Tap을 조정하면 약 15V의 전압조정이 가능하지만, 한전배전규정전압이 220±13V의 범위가 벗어나지 않는 한 Tap을 조정해 주지 않는 문제점이 있다. 셋째, 인버터의 댓 수를 제한하면 인버터 과전압 범위 안에서 인버터를 기동할 수 있다. 넷째, 단상이 아닌 삼상으로 연계하면 전압이 분배되어 전압상승을 방지 할 수 있다. 4가지 중 현장 적용이 용이한 것은 역률제어 및 능동전압제어 인버터를 사용하는 것임을 확인하였다.

초전도 케이블 냉각유로에서의 압력강하 특성 (Pressure Drop Characteristics on HTS Power Cables with LN2 Flow)

  • 고득용;염한길;이관수
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.81-86
    • /
    • 2006
  • High temperature superconducting (HTS) power cable requires forced sub-cooled LN2 flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65 K and 77 K. The HTS power cable needs sufficient cooling to overcome its low temperature heat load. For successful cooling, the hydraulic characteristics of the HTS power cable must be well investigated to design the cables. Especially, the pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. This paper describes measurement and investigation of the pressure drop of the cooling system. In order to reduce the total pressure drop of the cooling system, the flow rate of liquid nitrogen must be controlled by rotational speed of the circulation pump.