• 제목/요약/키워드: Load measurement

검색결과 1,664건 처리시간 0.037초

Numerical simulation of compressive to tensile load conversion for determining the tensile strength of ultra-high performance concrete

  • Haeri, Hadi;Mirshekari, Nader;Sarfarazi, Vahab;Marji, Mohammad Fatehi
    • Smart Structures and Systems
    • /
    • 제26권5호
    • /
    • pp.605-617
    • /
    • 2020
  • In this study, the experimental tests for the direct tensile strength measurement of Ultra-High Performance Concrete (UHPC) were numerically modeled by using the discrete element method (circle type element) and Finite Element Method (FEM). The experimental tests used for the laboratory tensile strength measurement is the Compressive-to-Tensile Load Conversion (CTLC) device. In this paper, the failure process including the cracks initiation, propagation and coalescence studied and then the direct tensile strength of the UHPC specimens measured by the novel apparatus i.e., CTLC device. For this purpose, the UHPC member (each containing a central hole) prepared, and situated in the CTLC device which in turn placed in the universal testing machine. The direct tensile strength of the member is measured due to the direct tensile stress which is applied to this specimen by the CTLC device. This novel device transferring the applied compressive load to that of the tensile during the testing process. The UHPC beam specimen of size 150 × 60 × 190 mm and internal hole of 75 × 60 mm was used in this study. The rate of the applied compressive load to CTLC device through the universal testing machine was 0.02 MPa/s. The direct tensile strength of UHPC was found using a new formula based on the present analyses. The numerical simulation given in this study gives the tensile strength and failure behavior of the UHPC very close to those obtained experimentally by the CTLC device implemented in the universal testing machine. The percent variation between experimental results and numerical results was found as nearly 2%. PFC2D simulations of the direct tensile strength measuring specimen and ABAQUS simulation of the tested CTLC specimens both demonstrate the validity and capability of the proposed testing procedure for the direct tensile strength measurement of UHPC specimens.

시간-주파수 영역 반사파 계측방법을 이용한 부하 저항 측정 시스템 구현 (The Implementation of Load Resistance Measurement System using Time-Frequency Domain Reflectometry)

  • 곽기석;박태근;윤태성;박진배
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권10호
    • /
    • pp.435-442
    • /
    • 2006
  • One of the most important topics about the safety of electrical and electronic system is the reliability of the wiring system. The Time-Frequency Domain Reflectometry(TFDR) is a state-of-the-art system for detecting and estimating of the fault on a wiring. In this paper, We've considered the load resistance measurement on a coaxial cable using TFDR in a way of expanded application. The TFDR system was built using commercial Pci extensions for Instrumentation(PXI) and LabVIEW. The proposed real time TFDR system consisted of the reference signal design, signal generation, signal acquisition, algorithm execution and results display part. To implement real time system, all of the parts were programmed by the LabVIEW which is one of the graphical programming languages. Using the application software implemented by the LabVIEW, we were able to design a proper reference signal which is suitable for target cable and control not only the arbitrary waveform generator in the signal generation part but alto the digital storage oscilloscope in the signal acquisition part. By using the TFDR real time system with the terminal resistor on the target cable, we carried out load impedance measurement experiments. The experimental results showed that the proposed system are able not only to detect the location of impedance discontinuity on the cable but also to estimate the load resistance with high accuracy.

대구경 현장타설말뚝의 지지력 측정 사례연구 (A Case Study on the Measurement and Estimation of Bearing Capacity of Large Diameter Bored Pile)

  • 이원제;정훈준;이우진;장기수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.285-292
    • /
    • 2000
  • Though there has been increasing use of large diameter drilled shaft as a foundation structure of bridges, current practice for quality control is to confirm the minimum required load carrying capacity during construction stage. For economic and appropriate design of drilled shaft, it is necessary to evaluate the load transfer mechanism by pile load tests during initial stage of construction and to use the test results as a feedback to a revision of initial design. In this paper, results of load tests peformed at several domestic sites are presented to investigate the load transfer characteristics of large diameter drilled shaft. It was found that most of the load on piles is sustained by shaft friction and that only small portion of the load reaches the bottom of the drilled shaft. Some test results of drilled shaft by Pile Driving Analyzer performed at same sites are also presented to compare the load transfer characteristics interpreted from static pile load tests.

  • PDF

Load Cell Noise 제거를 위한 Digital Load Cell 에 대한 연구 (A study on a digital load cell for the removal of load cell noise)

  • 이영진;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.562-564
    • /
    • 2002
  • Noise reduction and a simplification of a precision measurement system has been performed by changing analog output mode of a load cell into digital output mode. Usually, analog output signal of a few $\mu V$ from a load cell are amplified by amp and acquired by A/D converter. If the distance from a load cell to a DAS(Data Acquisition System) increases, more noise signals are mixed. So, a microprocessor has been integrated into a load cell so that the amplification and A/D conversion of output signals could be done in close proximity to the lode cell for the reduction in mixing of noise. Obtained data from the load cell like this manner are transferred to a computer with digital values(of TTL level). To simplify the configuration of a multi-channel DAS, RS-485 communication system has used for data transfer.

  • PDF

트랙터 변속기의 부하 스펙트럼 개발 (Development of a Load Spectrum of Tractor Transmission)

  • 김대철;김경욱;이주완
    • Journal of Biosystems Engineering
    • /
    • 제23권6호
    • /
    • pp.539-548
    • /
    • 1998
  • This study was intended to develop a load spectrum acting on a transmission of agricultural tractors. Transmission loads were measured at the input shaft of the transmission and final drive shaft of the tractors. The measurement were conducted in five field conditions at two speed levels under plowing operations in Korea. Two torque transducers were developed for the respective load measurements and other necessary instrumentations were made to collect the data and store them in a data logger. The time-histories of the torque loads were analyzed and transformed into the load spectra using the rainflow counting and Smith-Watson-Topper methods. Comparisons of the load spectra developed under different conditions were made to investigate their characteristics. The effects on the load levels of soil and plowing speeds were also investigated. Finally, a load spectrum combining the results of the spectrum analysis was developed and proposed as a load source for the reliability test of transmissions.

  • PDF

경량벽체에 작용하는 인간에 의한 정적하중의 특성 (Characteristic of Human Static load Acting on the Lightweight Wall)

  • 송정현;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.192-193
    • /
    • 2013
  • The purpose of this research is to comprehend experimentally the nature of human static load to wall for making use of the result as basic data to evaluate resisting force of lightweight wall. Human motions exerting static load are classified to 4 types, and two-hands pushing and shoulder pushing are defined as the instantaneously forcing motions with hands or shoulder put on the load plate, respectively. Back leaning and one-hand leaning are defined as motions of taking a rest in their respective comfortable posture. Measurement of static horizontal load caused by each motion showed that the highest load ratio depends on hardness of load plane and was 1.17~1.25 times of weight in two-hands pushing, 0.95~0.99 times in shoulder pushing, 0.16~0.18 times in back leaning, and 0.12~0.15 times in one-hand leaning.

  • PDF

다구찌 방법에 의한 유리-실리콘 양극접합 계면의 파괴인성치 측정 및 양극접합공정 조건에 따른 접합강도 분석 (Measurement of Glass-Silicon Interfacial fracture Toughness and Experimental Evaluation of Anodic Bonding Process based on the Taguchi Method)

  • 강태구;조영호
    • 대한기계학회논문집A
    • /
    • 제26권6호
    • /
    • pp.1187-1193
    • /
    • 2002
  • Anodic bonding process has been quantitatively evaluated based on the Taguchi analysis of the interfacial fracture toughness, measured at the interface of anodically bonded silicon-glass bimorphs. A new test specimen with a pre-inserted blade has been devised for interfacial fracture toughness measurement. A set of 81 different anodic bonding conditions has been generated based on the three different conditions for four different process parameters of bonding load, bonding temperature, anodic voltage and voltage supply time. Taguchi method has been used to reduce the number of experiments required for the bonding strength evaluation, thus obtaining nine independent cases out of the 81 possible combinations. The interfacial fracture toughness has been measured for the nine cases in the range of 0.03∼6.12 J/㎡. Among the four process parameters, the bonding temperature causes the most dominant influence to the bonding strength with the influence factor of 67.7%. The influence factors of other process parameters, such as anodic voltage and voltage supply time, bonding load, are evaluated as 18%, 12% and 2.3%, respectively. The maximum bonding strength of 7.23 J/㎡ has been achieved at the bonding temperature of 460$\^{C}$ with the bonding load of 45gf/㎠, the applied voltage of 600v and the voltage supply time of 25minites.

멀티에어컨의 성능평가 및 제어시스템 개발에 대한 연구 (Development of Performance Evaluation and Control System of Multi-Air Conditioner)

  • 이한원;고국원;권영철;이중현;이유진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1107-1114
    • /
    • 2005
  • The running condition of multi-system air conditioner is prone to vary largely as it is designed for individual conditioning in each space of middle and small sized buildings. This leads to overcooling in case of partial load run, while the lack of capacity happens in case of full load run. Besides these, there exist such problems as instabilities due to the uneven refrigerant distribution caused by fluctuation of load and the change in piping line. Based upon the basic study on the function characteristics found in parts needed for maximized system working design in order to troubleshoot, the system functioning pattern should be identified through the different tests with various operating circumstances and the analysis models should be developed. With this ground, the control logic has to be made to have a control over capacity and make possible the efficient distribution of refrigerant.

  • PDF

압력 측정에 의한 요량 계측의 유용성 분석 (Validation of Urine Volume Evaluation by Hydraulic Pressure Measurement)

  • 김경아;최성수;이인광;박경순;김원재;이태수;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권4호
    • /
    • pp.577-584
    • /
    • 2007
  • Uroflowmetry is non-invasive and easily performed to diagnose benign prostatic hypertrophy(BPH) frequent in aged men. Weight change during urination is usually measured to estimate the urinary flow rate by a load cell, but sensitive to any impacts against the bottom of the container, leading to unnecessary noise generation. Moreover, load cells are relatively expensive raising the production cost. The present study proposed a new technique, measuring hydraulic pressure on the bottom of the urine container to evaluate the urinary volume. Low cost pressure transducer enabled almost perfectly linear relationship between the urine volume and the hydraulic pressure. During both the simulated and human urination experiments, variance of the pressure signal was more than 50% smaller than the weight signal acquired by a load cell, which demonstrated that the impact noise was decreased to a great degree by pressure compared to weight measurement.

빙축열 시스템 냉동기 성능 및 축열밀도 현장측정 기법연구 (In-Situ Measurement of Chiller Performance and Thermal Storage Density of an Ice Thermal Storage System)

  • 신영기;양훈철;태춘섭;조수;김영일
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1204-1209
    • /
    • 2005
  • In-situ measurement was made to evaluate chiller performance and thermal storage density of an ice thermal storage system. The system belonged to a big hotel and the measurement was conducted during late October. Owing to very small cooling load, the data logging was possible for a single thermal storage cycle. However, operation history of the chiller showed a relatively good spectrum of data for performance evaluation. COP and thermal storage density were calculated. The COP at full load was about 4.07, which was lower than $4.8\~6.4$ of new chillers. The measured storage density was about $10.9RT-h/m^3\;(=152MJ/m^3)$, which also was lower than a criterion of normal performance $(above\;13.0RT-h/m^3\;or\;181MJ/m^3)$. The study result provides technical basis for quantitative ESCO business scenario.