• 제목/요약/키워드: Load flow calculation

검색결과 156건 처리시간 0.027초

하천유지유량을 이용한 일최대 오염허용부하량 산정 방안 (Calculation of Total Maximum Daily Load using Instreamflow Requirement)

  • 정은성;김경태;김상욱;이길성
    • 한국물환경학회지
    • /
    • 제24권3호
    • /
    • pp.317-327
    • /
    • 2008
  • This study developed the methodology to calculate the total daily maximum load (TMDL) using the instreamflow requirement because the previous TMDLs were too simple to easily achieve. Instreamflow requirement which was the average low flow ($Q_{275}$) in the previous planning cannot consider the seasonal variation of streamflow. Therefore, this study used the instreamflow requirement which is a maximum value among hydrologic drought flow ($Q_{355}$), and environmental flows for ecology and scenery. The environmental flows for ecology were calculated using Physical HABitat SIMulation system (PHABSIM) which can estimate the necessary flow for fish survival by life cycle. Using the proposed method, all monthly TMDLs of streams in the Anyangcheon were calculated for the application.

3상 조류계산에 의한 대규모 배전계통의 불평형상태 평가 (An Evaluation of Large Scale Distribution system Unbalance)

  • 송현선
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.86-93
    • /
    • 1999
  • 대규모 배전계통 설비의 합리적인 운용과 안전성을 제고하기 위해서는 시스템의 불평형 상태를 정확하게 파악하는 것이 필수적이다. 본 논문에서는 전송선로와 부하의 불평을 고려한 3상 조류계산에 의하여 시스템의 불평형상태를 평가하였다. 이를 위하여, 먼저 전송선로에서는 선로정수에 상호결합과 상배치 및 연가의 영향을 고려하여 모델링하였고, 변압기는 1, 2차의 결선방식에 대하여 상호결합관계를 고려하였고 변압기 철손도 전압의 함수로 표현하여 계산하였다. 발전기모델에서는 돌극효과를 고려할 수 있도록 하였으며, 전력조류계산 알고리즘에서는 전력방정식을 상전압으로 표현하여 뉴톤-랩슨법으로 프로그램화 하였다.

  • PDF

조상설비를 고려한 전압안정성 여유전력의 평가에 관한 연구 (A Study for Evaluating of Voltage Stability Margin Considering Shunt Capacitor)

  • 김세영
    • 에너지공학
    • /
    • 제7권1호
    • /
    • pp.65-72
    • /
    • 1998
  • 이 논문은 극좌표이 선로조류방정식을 이용하여 전압안정성 여유전력을 평가하는 고속계산법을 제안한다. 여기서, 선로조류방정식은 상태변수 Vi, $\delta$i, Vj와 $\delta$i 그리고, 선로정수 r과 x로 구성되는데 극좌표계의 특징을 이용하면 이것은 두 개의 변수 Vi와 Vj를 가진 하나의 식이 된다. 그리고, j 모선이 조류계산에서 전압크기로 지정되는 발전기 또는 slack 모선이라면, 변수 Vi만을 가진 하나의 식 즉, {{{{ { V}`_{i } ^{2 } }}에 대한 2차 방정식으로 정식화된다. 그러므로, 전력조류다근은 간단한 계산을 통해 구할 수가 있는데 이와 같이 구해진 다근은 감도해석 또는 다근의 근접도를 통해 전압안정도를 평가할 수 가 있었다. 또한, 전압안정도 평가시에 중요한 요소인 전력용 콘덴서와 같은 조상설비를 고려하여 전압안정성 여유전력을 평가하는 방법을 개발하였다. 제안한 방법을 시험계통에 적용하여 유효성을 입증하였다.

  • PDF

배전선로 상시연계점 측정 전압 위상차를 이용한 변전소 모선 위상각 추정 방법 (Substation Bus Voltage Angle Calculation Method Using Voltage Angle Difference Measured at the Tie Switch in the Distribution Line)

  • 손주환;임성일
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.9-15
    • /
    • 2016
  • Distribution networks are operated in radial fashion during the normal state. Loop configuration is also required temporally in case of live load transfer among the adjacent feeders. Voltage angles of each substation buses are very important data in order to calculate power flow of the loop structured distribution feeders. This paper proposes substation bus voltage angle calculation method using voltage angle difference measured at the normally open tie switches. Simulation case studies using Matlab simulink have been performed to establish feasibility of proposed method.

전자기펌프의 설계 및 액체금속 유동의 수치해석 (Design of an Electromagnetic Pump and Numerical Analysis of the Liquid Metal Flow)

  • 권정태;김서현;남택훈;임효재;김창업
    • 한국산학기술학회논문지
    • /
    • 제10권10호
    • /
    • pp.2589-2595
    • /
    • 2009
  • 본 연구에서는 장하분배법(Load Distribution Method) 및 등가회로법(Equivalent Circuit Method)을 이용하여 액체금속이송을 위한 전자기펌프를 설계하고 제작하였다. 제작된 전자기펌프의 구동전력과 이에 상응하는 액체의 유량관계를 구하였다. 액체금속유동에 가하는 전자기 힘(Lorentz force)의 크기에 따른 유속과 유량을 수치해석기법을 이용하여 계산하였다. 수치해석결과를 상용코드인 FLUENT를 이용하여 계산한 결과와 비교하고 분석하였다. 다양한 전자기력의 크기에 대한 액체금속(우드메탈)의 평균속도에 대한 결과는 FLUENT의 결과와 5%이내의 오차 내에서 잘 일치하였다.

발생부하원단위와 수치표고모형을 이용한 하천유역 오염부하량 산정 (Calculation of Pollutant Loadings from Stream Watershed Using Digital Elevation Model and Pollutant Load Unit Factors)

  • 양홍모;김혁
    • 한국조경학회지
    • /
    • 제29권1호
    • /
    • pp.22-31
    • /
    • 2001
  • The purpose of this study is to compare calculated pollutant loadings using pollutant load unit factors and vector type coverage, and expected mean concentration(EMC) and raster type of digital elevation model(DEM). This study is also focusing on comparison of the advantages and the disadvantages of the two methods, and seeking for a method of calculation of pollutant loadings using DEM. Estimation of pollutant inputs using pollutant load unit factors has limitations in identifying seasonal variations of pollutant loadings. Seasonal changes of runoffs should be considered in the calculation of pollutant loadings from catchments into reservoirs. Evaluation of pollutant inputs using runoff-coefficient and EMC can overcome these drawbacks. Proper EMC and runoff-coefficient values for the Koeup stream catchments of the Koheung estuarine lake were drawn from review of related papers. Arc/Info was employed to establish database of spatial and attribute data of point and non-point pollutant sources and characteristics of the catchments. ArcView was used to calculate point and non-point pollutant loadings. Pollutant loads estimated with either unit factors-coverages, i.e., pollutant load unit factors and vector coverages f point sources and land use, or EMC and digital elevation mode(DEM) were compared with stream monitoring loads. We have found that some differences were shown between monitoring results and estimated loads by Unit Factors-Coverage and EMC-DEM. Monthly variations of pollutant loads evaluated with EMC-DEM were similar to those with monitoring result. The method using EMC-DEM can calculate accumulated flows and pollutant loads and can be utilized to identify stream networks. A future research on correcting the difference between vector type stream using flow direction grid and digitalizing vector type should be conducted in order to obtain more exact calculation of pollutant loadings.

  • PDF

부하구성비를 이용한 부하예측에 관한 연구 - 주거용 부하를 중심으로 한 (A Study the load Forecasting Techniques using load Composition Rates (Residential load))

  • 박준열;임재윤;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.82-85
    • /
    • 1993
  • The load forecasting has been essential in planning and operation of power systems. The load composition rata is also needed to analyze power-systems - load flow calculation and system stability. This paper proposes the monthly peak load forecasting methods for load groups in residential class using load composition rate and electric consumption characteristics. The proposed methods were applied to a real-scale power system and the effectiveness was turned out.

  • PDF

다중조류계산을 이용한 전압붕괴 임계점의 On-Line 계산 (On-Line Calculation of the Critical Point of Voltage Collapse Based on Multiple Load Flow Solutions)

  • 남해곤;김동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.134-136
    • /
    • 1993
  • This paper presents a novel and efficient method to calculate the critical point of voltage collapse. Conjugate gradient and modified Newton-Raphson methods are employed to calculate two pairs of multiple load flow solutions for two operating conditions, i.e., both +mode and -mode voltages for two loading conditions respectively. Then these four voltage magnitude-load data sets of the bus which is most susceptible to voltage collapse, are fitted to third order polynomial using Lagrangian interpolation in order to represent approximate nose curve (P-V curve). This nose curve locates first estimate of the critical point of voltage collapse. The procedure described above is repeated near the critical point and the new estimate will be very close to the critical point. The proposed method is tested for the eleven bus Klos-Kerner system, with good accuracy and fast computation time.

  • PDF

Investigation on the Flow Field Upstream of a Centrifugal Pump Impeller

  • Zhang, Yao;Luo, Xianwu;Yi, Yunchi;Zhuang, Baotang;Xu, Hongyuan
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.209-216
    • /
    • 2011
  • The flow upstream of a centrifugal pump impeller has been investigated by both experimental test and numerical simulation. For experimental study, the flow field at four sections in the pump suction is measured by using PIV method. For calculation, the three dimensional turbulent flow for the full flow passage of the pump is simulated based on RANS equations combined with RNG k-$\varepsilon$ turbulence model. From those results, it is noted that at both design lo ad and quarter load condition, the pre-swirl flow whose direction is the same as the impeller rotation exists at all four sections in suction pipe of the pump, and at each section, the pre-swirl velocity becomes obviously larger at higher rotational speed. It is also indicated that at quarter load condition, the low pressure region at suction surface of the vane is large because of the unfavorable flow upstream of the pump impeller.

Derivation of Distributed Generation Impact Factor in a Networked System in Case of Simultaneous Outputs of Multiple Generation Sites

  • Lim, Jung-Uk;Runolfsson, Thordur
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.78-83
    • /
    • 2006
  • A new measure, the distributed generation impact factor (DGIF), is used for evaluating the impact of newly introduced distributed generators on a networked distribution or a transmission system. Distribution systems are normally operated in a radial structure. But the introduction of distributed generation needs load flow calculation to analyze the networked system. In the developed framework, the potential share of every generation bus in each line flow of a networked system can be directly evaluated. The developed index does not require the solution of power flow equations to evaluate the effect of the distributed generation. The main advantage of the developed method lies in its capability of considering simultaneous outputs of multiple generation sites.