• Title/Summary/Keyword: Load efficiency

Search Result 3,185, Processing Time 0.027 seconds

Optimal Redundant Units and Load in Parallel Systems (병렬 시스템에서의 최적 중복부품수와 최적 부하수준)

  • 윤원영;김귀래
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.23 no.1
    • /
    • pp.97-107
    • /
    • 1998
  • This paper is concerned with a parallel system that sustains a time-independent load and consists of n components with exponential lifetimes. It is assumed that the total load is shared by the working components and the failures of components increase higher failure rates in the surviving components according to the relationship between the load and the fialure rates. The power rule model among several load-failure rate relationships is considered. We consider the system efficiency meausre as the expected profit earned by the system per unit time. The high load causes high gain but it also occurs frequent system failures. The expected profit per unit time is used as criterion to evaluate the system efficiency. The goal of system engineer is to determine the optimal load and redundant units maximizing the expected profit per unit time. First, the system reliability function is obtained and the optimization problem of the load-sharing parallel system is considered. Given the redundant units, the existence of the optimal load can be proved analytically and given the load, the optimal redundant units can be solved also analytically. The optimal load and redundant units are obtained simultaneously by numerical computation. Some numerical examples are studied.

  • PDF

An Adaptive Energy-Efficient and Low-Latency MAC Protocol for Wireless Sensor Networks

  • Liu, Hao;Yao, Guoliang;Wu, Jianhui;Shi, Longxing
    • Journal of Communications and Networks
    • /
    • v.12 no.5
    • /
    • pp.510-517
    • /
    • 2010
  • In this paper, an adaptive MAC protocol (variable load adaptive (VLA)-MAC) is proposed for wireless sensor networks. This protocol can achieve high energy efficiency and provide low latency under variable-traffic-load conditions. In the case of VLA-MAC, traffic load is measured online and used for adaptive adjustment. Sensor nodes transmit packets in bursts under high load conditions to alleviate packet accumulation and reduce latency. This also removes unnecessary listen action and decreases energy consumption in low load conditions. Simulation results show that the energy efficiency, latency, and throughput achieved by VLA-MAC are higher than those achieved by some traditional approaches.

Contactless Power Charger for Light Electric Vehicles Featuring Active Load Matching

  • Jiang, Wei;Xu, Song;Li, Nailu
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.102-110
    • /
    • 2016
  • Contactless power transfer technology is gaining increasing attention in city transportation applications because of its high mobility and flexibility in charging and its commensurate power level with conductive power transfer method. In this study, an inductively coupled contactless charging system for a 48 V light electric vehicle is proposed. Although this study does not focus on system efficiency, the generic problems in an inductively coupled contactless power transfer system without ferromagnetic structure are discussed. An active load matching method is also proposed to control the power transfer on the receiving side through a load matching converter. Small signal modeling and linear control technology are applied to the load matching converter for port voltage regulation, which effectively controls the power flow into the load. A prototype is built, and experiments are conducted to reveal the intrinsic characteristics of a series-series resonant inductive power charger in terms of frequency, air gap length, power flow control, coil misalignment, and efficiency issues.

Development of a Depth and Working Load Control System for Tractor Using a Proportional Valve (비례밸브를 이용한 트랙터 경심 및 부하제어시스템 개발)

  • Lee, S.S.;Lee, J.Y.;Mun, J.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.16-23
    • /
    • 2006
  • Depth and working load control is one of the most important technique in control system for tractor rotary implement automation. Keeping the depth consistent is critical to bring along crops and to improve the efficiency and quality of the following operations. Keeping the load of engine consistent is an essential factor for the efficiency of operation and engine protection of tractor. In this study we investigated the possibility of application of depth and working load control system for tractor using a proportional valve through field tests. Depth control was implemented by the ascent and descent of 3 point linkage for the change of setting depth. There were 4 mm and 5.2 mm control deviations for setting depths of 50mm and 100mm, respectively. Load control was operated appropriately by the ascent and of descent of 3 point link for the change of setting working load. The standard deviations between setting load and engine load were 171 rpm at 1.3 km/h and 164 rpm at 2.3 km/h tractor travel velocity. The results of experiment showed that the characteristics of response was sufficient to be used as the implement depth and working load control system for tractor using proportional valve.

Analysis of laboratory scale nitriation reactor using sludge thickener supernatant (농축조 상징액을 대상으로한 실험실 규모 아질산화 반응조 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.414-420
    • /
    • 2015
  • Nitrogen is one of main causes to induce eutrophication of water system and one of contaminants that must be treated for protection of water system. In this study, it was intended to identify a method to increase operation efficiency of municipal wastewater treatment plant (MWTP) by treating high concentration nitrogen. A laboratory scale reactor was operated by using sludge thickener supernatant in the MWTP. During operation of the laboratory scale reactor, it was intended to induce stable nitritation and analyze effects of related operation factors. As results, it was shown that the nitiritation could be induced artificially through control of retention time and sections where the stable nitiritation was induced were identified also. In particular, highly efficient nitrite conversion efficiency near 90% was identified in condition of 1 day retention time. Especially, it was shown that ammonium nitrogen load affected ammonium nitrogen removal efficiency and nitrite conversion efficiency. In the condition of high ammonium nitrogen load, the nitrite conversion efficiency and the ammonium nitrogen removal efficiency decreased. On the contrary in the condition of low ammonium nitrogen load, it was found that the nitrite conversion efficiency decreased. It means that control of ammonium nitrogen concentration and its retention time is needed for the nitritation. It is considered that for the sewage containing high load nitrogen in sludge treatment process as like the sludge thickener supernatant, the nitritation can be applied, which can be suggested as a modification method of MWTP.

Comparison with Load Transfer Efficiency for Joint Types in Airport Concrete Pavements (줄눈형식에 따른 공항 콘크리트 포장 하중전달율 비교)

  • An, Ji-Hwan;Jeon, Sung-Il;Kwon, Soo-Ahn;Kim, Min-Woo
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.9-20
    • /
    • 2014
  • PURPOSES : This study is to compare load transfer efficiency of key joint and dowel joint for airport concrete pavement. METHODS : As AC150/5320-6D of FAA's [Advisory Circular] was changed into AC150/5320-6E, Key joint type of rigid pavement were excluded from Construction Joints. LTE(Load Transfer Efficiency) of dowel joint and key joint were compared by times and seasons through pavement temperature measurement, ocular investigation and HWD measurement. RESULTS : For the joint performance grade of No. 2(The second) runway of airport, 12% of poor rate was observed in key joint and 2% of poor rate in dowel joint. Poor rate of key joint was increased to 17%, if only No. 3~No. 6 slabs, which are mostly loaded from the airplanes, were applied for the study. In apron area, LTE poor rate of key joint was high in winter, and LTE poor rate of dowel joint was at least above 'Fair' grade. In summer, 'Fair' for key joint, 'Acceptable' for dowel joint appeared. CONCLUSIONS : As results, dowel joint was superior than key joint for LTE. Deviations of seasons and times were smaller in dowel joint's result. And LTE in winter was lower than LTE in summer.

A New Approach to Improve Induction Motor Performance in Light-Load Conditions

  • Hesari, Sadegh;Hoseini, Aghil
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1195-1202
    • /
    • 2017
  • Induction motors often reach their maximum efficiency at the nominal load. In most applications, the machine load is not equal to the nominal load, thus reduces the motor efficiency and turns a greater percent of power into loss. In this paper, the induction motor control problem has been investigated to reduce the system losses. The Field Oriented Control method (FOC) has been employed in this paper. In this research, the mathematical equations related to system losses are calculated in relation to torque and speed, and then the q- and d-axis are summarized according to the current components. After that, the proposed method is applied along with d- and q-axis. In the recent three decades, many techniques have been suggested to improve the induction motor performance using smart and non-smart methods. In this paper, a new PSO-Fuzzy method have used in real time. The fuzzy logic method serves as speed controller in q-axis and PSO algorithm controls the optimum flux in d-axis. It will be proved that the use of this combined method will lead to a significant improvement in motor efficiency.

A Study on the Efficiency Improvement of Induction Motor with AC Voltage Controller (교류 전압 제어기에 의한 유도전동기의 효율 개선에 관한 연구)

  • Lee, Seung-Chul;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.137-139
    • /
    • 1991
  • This paper proposes a minimum power factor control for maximum efficiency operation of an induction motor, under low load condition. Minimum input or maximum efficiency operation is achived by properly adjusting the amplitude of the stator voltage, with the three phase AC voltage controller. Through the simulation, the relationships between the delay angle and input power under various load conditions are examined. Experimental results are also given, which show good coincidence with the simulation results.

  • PDF