• 제목/요약/키워드: Load characteristic experiment

검색결과 148건 처리시간 0.025초

내압과 굽힘하중을 받는 가스배관의 변형특성에 관한 연구 (A Study on the Deformation Characteristics of Gas Pipeline under Internal Pressure and In-Plane Bending Load)

  • 장윤찬;김익중;김철만;전법규;장성진;김영표
    • 한국압력기기공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.50-57
    • /
    • 2019
  • This paper investigates deformation characteristics of gas pipeline using the in-plane bending experiment and finite element analysis of a pipe bend. The effect of the bending angle and internal pressure on the deformation characteristics is analyzed. The pipe bend used in this study is API 5L X65 (out diameter: 20 inch) material with the thickness of 11.9 mm. The maximum load, displacement at maximum load, angle and local strain of 90° pipe bend are obtained from the in-plane bending experiment. Comparison between FE results and experimental data shows overall good agreements. In addition, the deformation characteristics of 22.5° and 45° pipe bend are calculated using the finite element analysis. As a result, the effect of the bend angle on the deformation characteristics is discussed.

저온초전도전원장치의 시스템 특성해석 및 요소실험 (Characteristic Analysis and Experiments on Components of Low-Tc Power Supply)

  • 윤용수;주민석;고태국
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권2호
    • /
    • pp.76-81
    • /
    • 2004
  • This paper deals with characteristic analysis and experiments on components of low-Tc(LTS) power supply. A LTS power supply consists of two exciters, a rotor, a stator, and an LTS magnet. The power supply has eight rotating poles, which make rotational magnetic flux. These flux penetrate superconducting sheets and cause currents which charge an LTS load. In this experiment, a 25.8mH LTS magnet was used, and rotor revolutions from 30 to 300rpm were used. In order to measure the pumping-current with respect to the magnet flux changes, a hall sensor was installed at the center of the LTS magnet. The experimental observations have been compared with the theoretical predictions. In this experiment, the pumping-current has reached about 372A.

복합재 체결부의 파손해석을 위한 새로운 특성길이 결정 방법 (A New Method to Determine the Characteristic Lengths for the Failure Analysis of Composite Joint)

  • 안현수;권진희;최진호
    • Composites Research
    • /
    • 제16권4호
    • /
    • pp.10-21
    • /
    • 2003
  • 본 논문에서는 특성길이 결정을 위해 시편에 가해지는 하중과 내부 응력분포의 관계가 거의 선형적으로 변한다는 특성을 이용하여. 실험을 수행하지 않고 복합재 체결부 파손해석을 위한 특성길이를 결정할 수 있는 방법을 제안하였다. 제안된 방법을 사용할 경우 특성길이 결정을 위한 실험 없이도 실험값을 사용한 결과와 동일한 압축특성길이를 얻을수 있음을 보였다. 압축특성길이 결정에서와 마찬가지로 실험 없이 인장특성길이를 결정하기 위해, 기존의 방법에서와 달리, 인장특성길이의 정의를 위해 사용하는 적층판의 강도값을, 원공이 없는 적층판의 값이 아닌 원공을 가진 적층판의 값을 사용하였다. 유한요소해석은 MSC/NASTRAN을 이용하였고, 체결재와 복합재의 접촉부는 접촉면 요소를 사용하여 모델링하였다. 제안된 방법으로 해석한 복합재 체결부의 파손하중은 Graphite/Epoxy 복합재료 체겯부의 실험 견과와 매우 잘 일치함을 확인하였다

와전류 커플링의 특성 비교 (Characteristic Comparison of Three Types of Eddy Current Coupling)

  • 장석명;조성국;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1036-1038
    • /
    • 2003
  • Electric control of eddy coupling offers many new possibilities in process control and other industrial control applications. And a form of speed control for the load is affected for a system driven by costant frequency induction motor. This paper compare speed-torque characteristic of three types of eddy-current coupling by using the analytical method. And characteristic experiment of three types of eddy current coupling is put into operation. And then, this paper will discuss operational and magnetic field characteristic of three types model.

  • PDF

The Practical Method and Experimental Verification of Temperature Estimation in the Permanent Magnet of Electric Machine

  • Kang, Kyongho;Yu, Sukjin;Lee, Geunho;Lee, Byeong-Hwa
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.421-426
    • /
    • 2015
  • This paper presents a practical method for estimation of average temperature in the permanent magnet (PM) of electric machine by using finite element analysis (FEA) and dynamo load experiment. First of all, the temperature effect of PM to the torque has been employed by FEA in order to evaluate the Temperature-Torque characteristic curve. The 1st order polynomial equation which is torque attenuation coefficient is derived by the FEA result of the Temperature-Torque curve. Next, torque saturation test with constant current condition is performed by dynamo load experiment. Then, the temperature trend can be estimated by adding the initial starting temperature using the torque attenuation coefficient and torque saturation curve. Lastly, estimated temperature is validated by infrared thermometer which measures temperature of PM surface. The comparison between the estimated result and experimental result gives a good agreement within a deviation of maximum $8^{\circ}C$.

Characteristic of Fatigue Crack Behavior on the Mixed-Mode in Aluminum Alloy 5083-O

  • Kim, Gun-Ho;Cho, Kyu-Chun;Lee, Ho-Yeon;Won, Young-Jun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.899-906
    • /
    • 2011
  • Generally, load conditions of machine or structure in fatigue destruction is occurred not under single load conditions but under mixed load conditions. However, the experiment under mixing mode is insufficient because of no having test standard to the behavior of crack under mixing mode and variety of test methods, and many tests are required. In this paper measured crack direction path by created figure capture system when a experiment. Also, we studied by comparison the behavior of crack giving the change of stress ratio and inserting beach mark. Through the test under mixing mode, advancing path of crack is indicated that advancing inclined angle ${\Theta}$ (direction of specimen length) has increased depending on the increase of mixed mode impaction. It is indicated that according to the increase of mixed mode loading condition impaction under mixing mode, advancing speed of crack gets slow. Also, we found that inner crack(cross section of specimen) is progressed more rapidly than outer crack based on data through beach mark.

쌍곡선포물선 대공간 구조물의 측벽개구율에 따른 지붕의 풍압특성 (Characteristic of Wind Pressure Distribution on the Roof of Hyperbolic Paraboloid Spatial Structures)

  • 유장열;유기표
    • 한국공간구조학회논문집
    • /
    • 제13권1호
    • /
    • pp.51-57
    • /
    • 2013
  • There can be diverse causes in the destruction of a large space structure by strong wind such as characteristics of construction materials and changes in internal and external wind pressure of the structure. To evaluate the wind pressure of roof against the large space structure, wind pressure experiment is performed. However, in this wind pressure experiment, peak internal pressure coefficient is set according to the opening of the roof in Korea wind code. In this article, it was tried to identify the change of internal pressure coefficient and the characteristics of wind pressure coefficient acting on the roof by two kinds of opening on the side of the structure with Hyperbolic Paraboloid Spatial Structures roof. When analyzing internal pressure coefficient according to roof shape, it was found that minimum (52%) and maximum (30%~80%) overestimation was made comparing to partial opening type proposed in the current wind load. It is judged that evaluation according to the opening rate of the structure should be made to evaluate the internal pressure coefficient according to load.

응축 및 증발 부하에 따른 냉동시스템 특성에 관한 연구 (A Study on the Characteristics of Refrigerating System according to the Condensation and Evaporation Load)

  • 최승일;지명국;이대철;정효민;정한식
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.44-49
    • /
    • 2013
  • The refrigerating system are high efficiency and comfortable due to the automation of the system as well as enhance energy saving are contributing to driving system. Previous study the rotational frequency of the compressor was confined to the fixed condition have changed load of evaporator and condenser related about the refrigerator performance characteristic according to the evaporation load and condensation load change tries to be analyze through the experiment. The useful data for the economic driving of the freezing apparatus tries to be drawn. Consequently, it confirmed that refrigerant in the compressor overheated and as the evaporation load increased the specific volume was increased and the coolant circulation rate decreased. In confirmed that condensation load increased the compression ratio and discharge gas temperature increased. It reduced the low-temperature efficiency and condensation calorie and the quality factor was decreased.

The effect of zirconia framework design on the failure of all-ceramic crown under static loading

  • Urapepon, Somchai;Taenguthai, Pakamard
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.146-150
    • /
    • 2015
  • PURPOSE. This in vitro study aimed to compare the failure load and failure characteristics of two different zirconia framework designs of premolar crowns when subjected to static loading. MATERIALS AND METHODS. Two types of zirconia frameworks, conventional 0.5 mm even thickness framework design (EV) and 0.8 mm cutback of full contour crown anatomy design (CB), were made for 10 samples each. The veneer porcelain was added on under polycarbonate shell crown made by vacuum of full contour crown to obtain the same total thickness of the experiment crowns. The crowns were cemented onto the Cobalt-Chromium die. The dies were tilted 45 degrees from the vertical plane to obtain the shear force to the cusp when loading. All crowns were loaded at the lingual incline of the buccal cusp until fracture using a universal testing machine with cross-head speed 0.5 mm/min. The load to fracture values (N) was recorded and statistically analyzed by independent sample t-test. RESULTS. The mean and standard deviations of the failure load were $1,170.1{\pm}90.9$ N for EV design and $1,450.4{\pm}175.7$ N for CB design. A significant difference in the compressive failure load was found (P<.05). For the failure characteristic, the EV design was found only cohesive failures within veneering porcelain, while the CB design found more failures through the zirconia framework (8 from 10 samples). CONCLUSION. There was a significant difference in the failure load between two designs, and the design of the framework influences failure characteristic of zirconia crown.

300KHz ZVS Full Bridge PWM 컨버터에 관한 연구 (A Study on the 300KHz ZVS Full Bridge PWM Converter)

  • 주형준;김의찬;최재동;손승찬;성세진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.111-115
    • /
    • 1997
  • This Paper is concerned on developing DC-DC converter using ZVS-FB-PWM Converter. The converter output is 28V and regulated by phase shift control methode. MOSFET is used by the main switching device and high frequency transfomer is made for operating at 300㎑ switching frequency. When the load vary widely, converter's ZVS characteristic is expressed by experiment result.

  • PDF