• 제목/요약/키워드: Load case

검색결과 3,587건 처리시간 0.028초

점진단조에 대한 기초 연구 (A basic study on incremental forging)

  • 조재현;박종진
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.341-344
    • /
    • 2009
  • Large load is required in forging of large-scale components, which becomes a critical restriction in practice. However, the load can be greatly reduced by adopting incremental forging technologies. In the present study, two methods of incremental forging were investigated for the purpose of reducing the load required. One was to use nine strokes with a flat die and the other was to use three strokes with a curved die. The die moves vertically in the former while it moves vertically as well as rolls horizontally in the latter. Deformation of the slab in each case was analyzed by rigid-plastic finite element method and as a result, variations of load and distributions of effective strain were predicted.

  • PDF

부하관리사업자의 부하배분 전략 (Allocation Strategies of Controllable Loads for Load Aggregator in Power Market)

  • 이찬주;조기선;김회철;박종배;신중린;김성수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.630-632
    • /
    • 2003
  • This paper describes allocation strategies of controllable loads for load aggregator in power market with the direct load control (DLC) program, which is carried out the two-way confirmation procedure. So, it is needed to the priority among the controllable loads to perform effectively and quickly the confirmation task. In this paper, allocation strategies for market operator and/or load aggregator are proposed, which are based on the basic load patterns defined in this paper. To verify the soundness of proposed strategies. case study on a sample system is performed.

  • PDF

Load Duration Curve를 이용한 분산전원과 배전계통의 신뢰도 산출 (Reliability Evaluation of Distributed Generation and Distribution System Using Load Duration Curve)

  • 배인수;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권11호
    • /
    • pp.518-524
    • /
    • 2005
  • This paper presents an analytical method for the reliability evaluation of distribution system, including the distributed generations. Unlike the large sized generations of transmission system, the distributed generations have complexities in analyzing and determining the operation. In the process of evaluate reliability, it can be shown that the analytical method is simpler than the Monte-Carlo simulation and the method using Load Duration Curve model is more accurate than that using peak load model. The modeling of distributed generation to analysis distribution system reliability using LDC is proposed in this Paper, and is compared with the MCS method as a result of case studies.

배전계통에 분산전원 연계시 전압강하에 의한 민감부하의 피해를 고려한 보호협조 연구 (A Study on the Coordination Scheme Considering the Loss of Sensitive Load by Voltage Sag at Distribution System Interconnected Dispersed Generation)

  • 정승복;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.363-365
    • /
    • 2003
  • Recently, the concern of power qualiaty problem is increasing. Especially, Voltage quality problem have been increased important problem. Electronic device was affected by voltage sag. So, sensitive load that included many electronic Device was affected by voltage sag. also, it may have economic loss. In this paper, we argue the coordination scheme considering the loss of sensitive load. The coordination device of distribution system for instaneous fault is recloser and sectionalizer, But, the fault clearing time of recloser is more than 2 seconds. So, voltage sag generates long time that affected sensitive load. HS(high speed switchgear) has fast fault clearing time(0.015s) that not affected sensitive load. Therefore, the coordination applied HS is used. The proposed schemes are proved and evaluated by a case study using PSCAD/EMTDC simulation.

  • PDF

Piled Raft 기초 적용사례 분석 (A Case Study of the Piled Raft Foundation)

  • 김홍택;강인규;최효범;박시삼
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.597-604
    • /
    • 2002
  • The piled raft foundation Is an innovative design concept to reduce both the maximum settlement and differential settlements caused by concentrated building loads and load eccentricities, and also to reduce the bending moments of the raft. The main concern given in the design of piled raft foundations is proper judgments both of relative proportions of loads carried by the raft and piles, and of the effect of the pile support on the maximum and differential settlements In the present study, the piled raft foundation used in the foundation system of Richensia Building at Youido, Seoul is introduced and is carried out analyzing the results of field tests such as plate load tests, large plate load test, pile load test, and piled raft load test.

  • PDF

구조공법별 환경부하 산출·비교분석에 관한 연구 (철근콘크리트구조와 철골구조를 중심으로) (Comparison of Environmental Load per Constructional Methods (Focus on Reinforced Concrete Structures and Steel-Frame Structures))

  • 문준호;이현주;정영철;김태희;김광희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.193-195
    • /
    • 2011
  • Nowadays, climatic environment change has become a major issue in the world. This causes major emissions of carbon dioxide industries steel industry, thermal power industry, cement industry is essential in the reduction of carbon dioxide, which is based on total carbon dioxide emissions account for most of the construction industry in an effort to minimize the environmental load is needed. accordingly, through case studies, It can be induce the selection to minimize environmental load by comparing the output of quantitative energy consumption and carbon dioxide emissions per constructional methods. As a result of this study, RC Structure was less environmental load than SC structure.

  • PDF

소비자 효용을 고려한 실시간 요금제의 Load Serving Entity 수익 설계 방안 (Evaluation of a Load Serving Entity Revenue in the Real Time Pricing Considering Customer's Utility)

  • 노준우;김문겸;김도한;유태현;박종근
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.266-272
    • /
    • 2011
  • Real Time Pricing(RTP) is used not only to stabilize the price volatility in electricity market, but to hedge the price risk for Load Serving Entity(LSE). This paper presents an efficient method to reduce the risk of the price volatility in real-time electricity market. For designing the RTP, load patterns of customer are calculated by applying the demand elasticity and customer's utility is also analyzed to compute the RTP revenue through the risk-attribute of the LSE. In the end, the distribution of the LSE's profits can be evaluated to lead the optimal RTP value, depending on the level of customer's participation. Results from the case study based on PJM data are reported to illustrate the proposed method.

TSAT을 이용한 우리나라 계통의 저주파수 부하차단 방식 검토 (A Study on Under-Frequency Load Shedding Scheme of Korea Electric Power System using TSAT)

  • 이강완;배주천;조범섭;오화진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.34-37
    • /
    • 2003
  • The frequency of power system will change when the load-generation equilibrium is disturbed. Insufficiency of generation from the imbalance between load and generation decreases the power system frequency. In case of the severe emergency, the under frequency load shedding scheme is applied for the power system defense plan. In this paper, we analyzed the dynamic characteristics of under frequency load shedding using new Transient Security Assessment Tool ; TSAT. We applied the actual UFLS scheme to these studies and considered the possible contingency.

  • PDF

시스템 식별법에 의한 부하모델링 (Load Modeling based on the System Identification)

  • 심건보;이봉용;김정훈;이형수;추진부;이상중;전영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.148-151
    • /
    • 1993
  • Load models for the analysis and simulation of power system are often introduced when the more accurate result is required. This work presents a single expressed load model as T-equivalent circuit of induction motor, for the composite characteristics of various loads. The parameters of the proposed load model are identified based on the system identification method as Recursive Least Square identification method. Case study results show the accuracy of proposed load model, and compared with some field measurements.

  • PDF

비주택용 전기난방기구가 우리나라 첨두부하에 미치는 영향 검토 (Investgating Effects of Peak Load of Korean Power System from Electric Heating appliances except House)

  • 김용하;이광성;허동렬;이성준;이용석;우성민;손승기
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.442-447
    • /
    • 2006
  • This paper investigates the shadow amount of edifice and according to time zone used by its Electric heating appliances, it is analyzed that Electric Heating Power Load affects Heal power load variation curve. Also, in case that the far infrared ray heating system, which are used as new electric heating system, occupies some of the existing Electric heating appliances, it is analyzed that the Electric heating power load affects the Peak load power in Korea.

  • PDF