과부하에 따른 배전용 변압기의 절연유 열화검출 (Analysis of Transformer Fluid Aging from Overload Operation)

  • 정종만;이병성;김주용;송일근;김병숙
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.49-53
    • /
    • 2006
  • In this paper the thermal aging characteristics of transformer fluid were considered. First, the temperature rise characteristic in transformer winding was discussed. The temperatures were rapidly increased immediately with applying load and then the temperature was followed the exponential temperature rise model. Next, Capacitance and leakage current characteristics of the transformer fluid were measured during the over-loading operation. The capacitance of vegetable fluid and leakage current were evidently increased wit aging time. So the simple methods could be applied to diagnosis of the transformer aging

  • PDF

Novel Single-inductor Multistring-independent Dimming LED Driver with Switched-capacitor Control Technique

  • Liang, Guozhuang;Tian, Hanlei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.1-10
    • /
    • 2019
  • Current imbalance is the main factor affecting the lifespan of light-emitting diode (LED) lighting systems and is generally solved by active or passive approaches. Given many new lighting applications, independent control is particularly important in achieving different levels of luminance. Existing passive and active approaches have their own limitations in current sharing and independent control, which bring new challenges to the design of LED drivers. In this work, a multichannel resonant converter based on switched-capacitor control (SCC) is proposed for solving this challenge. In the resonant network of the upper and lower half-bridges, SCC is used instead of fixed capacitance. Then, the individual current of the LED array is obtained through regulation of the effective capacitance of the SCC under a fixed switching frequency. In this manner, the complexity of the control unit of the circuit and the precision of the multichannel outputs are further improved. Finally, the superior performance of the proposed LED driver is verified by simulations and a 4-channel experimental prototype with a rated output power of 20 W.

디지털 통신 응용을 위한 $MnO_2$, Pseudo-capacitor의 시스템 설계 및 성능평가 (System Design and Performance Analysis of $MnO_2$ Pseudo-capacitor for Digital Communication Applications)

  • 성우경;홍명신;김선욱
    • 전기화학회지
    • /
    • 제3권4호
    • /
    • pp.241-245
    • /
    • 2000
  • 비정질 $MnO_2\;nH_2O$ 전극재료를 사용한 pseudo-capacitor를 설계 제작하여 특성을 평가하였다. 100mV/s의 cyclic voltammogram으로부터 측정한 결과, 이 전극재료의 안정한 potential window는 1V이고 비용량은 250F/g이었다. TDMA(Time Division Multiplex Algorithm) pulse 시험에서 TDMA 시스템 (2 parallel-pseudo-capacitor systems) 은 0.22V의 ohmic voltage drop과 0.38V의 capacitor voltage drop을 보여주었다. 이 TDMA system의 total voltage drop이 0.60V이므로 TDMA 위성통신 휴대전화의 요건인 1V maximum voltage drop을 충족하였다. 또한, 이 system의 ESR과 비용량은 각각 $55m{\Omega}$과 105mF이었다. 따라서 이 TDMA system이 위성통신 휴대전화를 위한 load-leveling 캐패시터로 응용 가능함을 확인하였다.

Implementation of a ZVS Three-Level Converter with Series-Connected Transformers

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.177-185
    • /
    • 2013
  • This paper studies a soft switching DC/DC converter to achieve zero voltage switching (ZVS) for all switches under a wide range of load condition and input voltage. Two three-level PWM circuits with the same power switches are adopted to reduce the voltage stress of MOSFETs at $V_{in}/2$ and achieve load current sharing. Thus, the current stress and power rating of power semiconductors at the secondary side are reduced. The series-connected transformers are adopted in each three-level circuit. Each transformer can be operated as an inductor to smooth the output current or a transformer to achieve the electric isolation and power transfer from the input side to the output side. Therefore, no output inductor is needed at the secondary side. Two center-tapped rectifiers connected in parallel are used at the secondary side to achieve load current sharing. Due to the resonant behavior by the resonant inductance and resonant capacitance at the transition interval, all switches are turned on at ZVS. Experiments based on a 1kW prototype are provided to verify the performance of proposed converter.

유도 전동기용부하(負荷) 전류식(轉流式) 전류형(電流形) 인버터의 해석 (Analysis of a Load Commutated Current Source Inverter for Induction Motors)

  • 송중호;윤태웅;김광배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.313-316
    • /
    • 1989
  • A steady state analysis of a load commutated current source inverter which is widely used in high voltage - high power induction motor drive systems at present is presented and its related results are discussed. This analysis proposes a method by which we can determine the output capacitor playing a dominant role on the performance of the system. It is shown that the capacitance of output capacitors is mainly dependent on the range of frequencies that the inverter is operated in the load commutated state.

  • PDF

A Fast Low Dropout Regulator with High Slew Rate and Large Unity-Gain Bandwidth

  • Ko, Younghun;Jang, Yeongshin;Han, Sok-Kyun;Lee, Sang-Gug
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권4호
    • /
    • pp.263-271
    • /
    • 2013
  • A low dropout regulator (LDO) with fast transient responses is presented. The proposed LDO eliminates the trade-off between slew rate and unity gain bandwidth, which are the key parameters for fast transient responses. In the proposed buffer, by changing the slew current path, the slew rate and unity gain bandwidth can be controlled independently. Implemented in $0.18-{\mu}m$ high voltage CMOS, the proposed LDO shows up to 200 mA load current with 0.2 V dropout voltage for $1{\mu}F$ output capacitance. The measured maximum transient output voltage variation, minimum quiescent current at no load condition, and maximum unity gain frequency are 24 mV, $7.5{\mu}A$, and higher than 1 MHz, respectively.

부하측에 에너지 회생회로를 갖는 전류원 인버터 (New current source inverter with load-side energy recovery circuit)

  • 정용호;조규형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.117-120
    • /
    • 1988
  • A new current source inverter (CSl) with dc-side commutation and load-side energy recovery circuit is proposed with analysis and explanation of the circuit operation. Proposed inverter overcomes the most drawbacks of the conventional CSI's - high device voltage stress, low operating frequency range, large commutation capacitance, etc. - by employing simultaneous recovery and commutation concept. The new CSI employs only one commutation capacitor and it can be built with considerably low cost. The commutation energies are temporarily stored into a large dc capacitor and recovered to the load side, thus the device voltage stress is low and the efficiency is high in the proposed inverter. Computer simulation results are given at the steady state, and a guideline determining the commutation circuit is given.

  • PDF

불평형 부하에서의 능동필터에 관한 연구 (The Study on the Active Power Filter in Unbalanced Load)

  • 최시영;이우철;이택기;현동석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권3호
    • /
    • pp.130-140
    • /
    • 2001
  • This paper presents the performance of a parallel active power filter(PT) system in unbalanced load condition. The unbalanced load leads to negative sequence of current, and makes 120Hz ripple in the DC-link voltage forcing large capacitance and increases the rating of APF. thus, the separation of negative sequence is performed in synchronous reference frame and controlled to flow into supply network. The validity of the scheme is investigated through simulation and the experimental results for a prototype active power filter system rated at 10kVA.

  • PDF

부하변동에 속응하는 역률개선형 전력절감시스템 (Electric energy saving system with high speed response to load variation using power-factor correction)

  • 김태수;강형식;주경돈;류승헌;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2388-2390
    • /
    • 2002
  • Small type electric energy saving system is proposed in this paper. The system improves power factor fastly according to load variation of each customer. Phases of voltage and current are detected as 1[ms] unit. Phase coincident algorithm is applied for power factor improvement. Capacitance is controlled for optimal power factor correction. Series reactor is controlled for harmonics reduction. Non-contact device is used for fast response and long life. Test result shows the effect of this system. Power factor of 40[W] electric fan is improved from 95[%] to 100[%]. In the case of electric light, power factor is improved from 82[%] to 100[%]. Response time for load variation is less than 1[ms].

  • PDF

계통연계형 인버터의 LCL필터 최적 설계기법 (Optimized LCL filter Design Method of Utility Interactive Inverter)

  • 정상혁;최세완
    • 전력전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.103-109
    • /
    • 2013
  • The conventional LCL filter design method of the utility interactive inverter considers only harmonics attenuation of the current injected to the grid. However, in case of utility-interactive inverter with critical load the voltage quality of the critical load should also be considered for LCL filter design. Also, considering cost and volume of LCL filters. it is important to have minimum values of inductance and capacitance as far as the harmonic standards are satisfied. In this paper a LCL filter design method is proposed to satisfy not only the harmonic standards of the grid current during the grid-connected mode but the voltage quality of the critical load during grid-connected mode and stand-alone mode. With the proposed method optimized values of LCL filters could be obtained by applying weighting factor to voltage ripple across the critical load, inductor volume, amount of reactive current and system bandwidth.