• 제목/요약/키워드: Load Transfer

검색결과 1,614건 처리시간 0.025초

상정사고별 배전측 부하분담 능력 분석과 도체 규격 검토 (Analysis of the Load Transfer Capacity and Study of Conductor Sizes for Contingency Levels in Distribution Systems)

  • 조남훈;전영재;한용희;한병성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.363-370
    • /
    • 2003
  • This paper presents the analysis of the load transfer capacity and study of conductor size for variable contingencies in distribution systems. The operation capacity of feeders was changed to improve operation efficiency in KEPCO, considerations for contingencies are still based on the previous capacity. In order to cope with the changes such as operation capacity, it is necessary to study whether the present "contingency support criteria" is reasonable or not, also to confirm the whether the present criteria should be improved or not. We analyze the load transfer capacity and conductor size on a distribution system for contingency levels such as the substation-level, bank-level, feeder-level, and zone-level.one-level.

순간전압강하 저감을 위한 방사상 배전계통에서의 부하 절환 스위칭 (Load Transfer Switching for Reducing the Voltage Sag's Effect in Radial Power Distribution System)

  • 윤상윤;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.208-210
    • /
    • 2000
  • In this paper, we present a method for mitigating the effect of voltage sag in radial power distribution systems using load transfer switching (LTS). The term of LTS is defined that the weakness load points for voltage sag transfer to the alternative source during the fault clearing practices. The sequences of proposed LTS method is divided into the search of weakness points for voltage sag using the risk assessment model and transfer behavior of weakness points. Through the case studies, we verify the effectiveness of proposed LTS method and present the searching method of effective application points of LTS method using the risk assessment model.

  • PDF

구름거동에 미치는 은 입자 투여의 영향에 대한 실험적 고찰 (Effect of Silver Particle Introduction on Rolling Friction)

  • 양승호;공호성;윤의성;김대은
    • Tribology and Lubricants
    • /
    • 제17권6호
    • /
    • pp.417-426
    • /
    • 2001
  • The effect of silver particle introduction on the rolling friction of AISI 52100 steel pairs has been investigated. Experiments ware performed in dry conditions using a thrust bearing-type rolling test rig at a load range of 12-960 N and a sliding velocity range of 8-785 mm/sec with pure (99.99%) silver particles. Results showed that introduced silver particles formed transfer layers, which protected the virgin bearing surfaces and resulted in the low lolling friction. By changing the quantity of silver particles, transitions in the rolling friction were found. Results also showed that the variations in normal load and rolling speed also affected the rolling friction behavior. Analyses of SEM and EPMA showed that the formation the transfer layer was mainly governed by the silver particle quantity, normal load and rolling speed, and this resulted in the different behavior of rolling friction. In this study, it was found that the low and stable rolling friction was resulted from the, shakedown phenomena occurred at the silver transfer layer.

구름거동에 미치는 은 입자 투여의 영향에 대한 실험적 고찰 (Effect of Silver Particle Introduction on Rolling Friction)

  • 양승호;공호성;윤의성;김대은
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.105-113
    • /
    • 2001
  • The effect of silver particle introduction on the rolling friction of AISI 52100 steel pairs has been investigated. Experiments were performed in dry conditions using a thrust bearing-type rolling test rig at a load range of 12 - 960 N and a sliding velocity range of 8 - 785 mm/sec with pure(99.99%) silver particles. Results showed that the introduced silver particles formed transfer layer, which protected virgin bearing surfaces and resulted in low rolling friction. By changing the quantity of silver particles, transitions in the rolling friction wear found. Results also showed that the variations in normal load and rolling speed also affected the rolling friction behavior. Analyses using SEM and EPMA showed that tile formation of transfer layer was mainly governed by the silver particle quantity, normal load and rolling speed, and this resulted in the different behavior of rolling friction. In this study, it was found that the low and stable rolling friction was resulted from the shakedown phenomena occurred at the silver transfer layer.

  • PDF

등가 전단 스프링 모델을 이용한 플로팅 슬래브궤도 연결부에서의 하중전달 특성 분석 (Investigation of Load Transfer Characteristics at Slab Joints In The Floating Slab Track by Equivalent Shear Spring Model)

  • 장승엽;안미경;최원일;박만호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2838-2843
    • /
    • 2011
  • Recently, the floating slab track that can effectively mitigate the vibration and structure-borne noise is being discussed to be adopted. The floating slab track which is a track system isolated from the sub-structure by vibration isolators. Unsimilarly to conventional track and the slab deflection is large. Therefore, the running safety and ride comfort should be investigated. Especially at slab joint since the load cannot be transferred, the possibility that the dynamic behavior of track and train became unstable is high. Thus, in general dowel bar are often installed at slab joints. To determine the appropriate dowel ratio the load transfer characteristics should be investigated. In this study, dowel bar joint is modeled by equivalent shear spring and this model is verified by comparison with experimental results. Using the proven model, the load transfer efficiency and deflection at slab joint according to dowel ratio, and stiffness and spacing of vibration isolator were examined.

  • PDF

Investigation of load transfer along interfaces of jacketed square columns

  • Achillopoulou, Dimitra V.
    • Structural Engineering and Mechanics
    • /
    • 제63권3호
    • /
    • pp.293-302
    • /
    • 2017
  • This study deals with a numerical investigation of load transfer along interfaces of jacketed columns using finite element models. Appropriate plasticity and constitutive models are used to simulate the response of concrete and steel bars. Experimental data were used to calibrate the simulation of mechanical characteristics. The different compressive strength of core and jacket concrete, the confinement ratio, the dowels' diameter size and the load pattern shapes were considered. The path diagrams along the interfaces elucidate the areas around the dowel bars where due to stress concentration plastic hinges and intense discontinuities are created. The stress flow also depicts the contribution of confinement of the jacketed area to the overall resonant load capacity of the core column. The scope of the research is to identify and quantify the shear transfer along the interfaces of strengthened elements.

마이크로히터에서 반주기 정현곡선의 열부하에 의한 비정상 열전달 연구 (NUMERICAL STUDY OF UNSTEADY HEAT TRANSFER ON MICRO HEATER UNDER HALF-CYCLE SINUSOIDAL HEAT LOAD)

  • 김명준;이희준
    • 한국전산유체공학회지
    • /
    • 제19권4호
    • /
    • pp.1-7
    • /
    • 2014
  • A numerical study of transient conjugate heat transfer on micro heater in a micro-channel substrate under a sinusoidal heat load was conducted. It was found that the time constant is not affected by the maximum heating magnitude of the sinusoidal heat load. However, the time constant increases with low duration of the sinusoidal heating period and low Reynolds number. Moreover, there is a threshold where a heater temperature do not reach to time constant at low thermal diffusivity, low flow rate, and low pulse duration of the sinusoidal heating. The time constant should be considered for transient convective heat transfer under transient sinusoidal heat load in a micro heat sink.

나선형 원형철근으로 보강된 집중배치 텐던 정착구역에 대한 하중전달시험 (Load Transfer Test of Spirally Reinforced Anchorage Zone for Banded Tendon Group)

  • 조아서;강현구
    • 한국공간구조학회논문집
    • /
    • 제17권1호
    • /
    • pp.59-67
    • /
    • 2017
  • In this study, load transfer tests based on KCI-PS101 were conducted to verify the performance of spiral anchorage zone reinforcement for banded post-tensioning (PT) monostrands. With results, the compressive strength of spiral reinforcement was increased by about 20% than that of specimens with two horizontal steel bars and 8% than that of U-shaped bars. Advanced spiral reinforcement for corner increases compressive strength and can resist the spalling forces or fall-out effect at the corner by shear. The ratio of maximum load to amount of steel of the spiral reinforcement is about twice than that of U-shaped reinforcement. With increase of compressive strength capacity and improvement of constructability, the spiral reinforcement is considered to have advantages of promoting the performance of PT anchorage zone compared to conventional methods.

풍화된 암반에 근입된 현장타설말뚝의 하중전이기구 (Load Transfer Mechanism of Drilled Shafts in Weathered Rock)

  • 권오성;조성민;정성준;김명모
    • 한국지반공학회논문집
    • /
    • 제21권5호
    • /
    • pp.187-196
    • /
    • 2005
  • 풍화 및 절리가 발달한 암반에 근입된 말뚝의 허용지지력 결정에는 침하량이 매우 중요한 인자가 되며, 설계단계에서 말뚝두부의 침하량을 예측하기 위해서는 말뚝의 하중전이기구에 대한 이해가 필수적이다. 따라서 본 연구에서는 풍화된 암반에 근입된 현장타설말뚝의 하중전이기구에 대한 연구를 수행하였다. 이를 위해 직경 1m의 총 5본의 현장 타설말뚝을 풍화된 편마암 부지에 시공하구 재하시험 및 하중전이 계측을 수행하여 말뚝의 축방향 지지거동을 분석하였다. 암반상태를 정량적으로 파악하기 위하여 재하시험 부지의 암반에 대한 엄밀한 현장/실내시험을 수행하고, 이를 토대로 암반상태가 말뚝의 하중전이기구에 미치는 영향을 분석하였다. 하중전이 계측을 통해 얻은 주면하중전이 (f-w) 곡선은 풍화상태가 상대적으로 양호한(MW) 연암의 경우, 수 mm의 변위에서 항복에 도달하며, 이후 변위에 따른 지지하중의 증가율이 급격히 둔화되는 경향을 보였다. 반면 풍화암/풍화토에 근입된 말뚝의 f-w 곡선은 뚜렷한 항복점을 보이지 않으며, 상대적으로 큰(>15m) 변위까지 주면하중이 쌍곡선 형태로 증가하였다. 선단하중전이(q-w) 곡선은 암반상태에 관계없이 선단변위 (q-w)까지는 선형적인 거동을 보였다.

지열을 이용한 공조외기부하저감(空調外氣負荷低減) 시스템의 설계 및 도입 효과에 관한 연구 - 증기 확산지배에 의한 열수분 동시 이동 수치모델의 제안 - (Study on Designing and Installation Effect of Fresh Air Load Reduction System by using Underground Double Floor Space - Proposal of Numerical Model coupled Heat and Moisture Simultaneous Transfer in Hygroscopic -)

  • 손원득;최영식
    • 한국산업융합학회 논문집
    • /
    • 제7권4호
    • /
    • pp.331-340
    • /
    • 2004
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we used a model for evaluation of fresh air latent heat load reduction by hygroscopic of air to earth exchange system taking into account coupled heat and moisture transfer of underground double floor space. In conclusion it shows the validity of the proposed method for a design tool and the quantitative effect of the system.

  • PDF