• 제목/요약/키워드: Load Transfer

검색결과 1,614건 처리시간 0.024초

Load Balancing Strategy for P2P VoD Systems

  • Huang, Guimin;Li, Chengsen;Liu, Pingshan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권9호
    • /
    • pp.4207-4222
    • /
    • 2016
  • In a P2P (Peer-to-Peer) VoD (video-on-Demand) streaming system, the nodes' load is an important factor which affects the system performance. In the system, some nodes may receive too many requests, which leads to overload. On the other hand, some other nodes may receive too few requests, which leads to low utilization. Therefore, designing a reasonable load balancing strategy is important. However, existing related studies cannot handle this problem effectively, because they don't have an efficient dynamic load information management mechanism, and they don't distinguish the difference of requests when transfer the nodes' load. In this paper, to manage the dynamic load information efficiently, we design a load management table for each node. Based on the load information, we propose a load balancing strategy which uses a request migration algorithm (LBRM). Through simulations, our scheme can handle the load imbalance problem effectively and improve the users' playback fluency.

ETAG 013 규정에 따른 원형 정착구의 하중전달실험 (Load transfer test of circular anchorage system according to ETAG 013)

  • 김범준;김현기
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.167-175
    • /
    • 2018
  • 정착구의 성능 평가를 위한 대부분의 기존연구와 성능실험들이 ETAG 013 규정에 따라 실험체를 제작하고 실험을 수행한 것으로 명시해오고 있다. 하지만 실험체에 사용된 파열력 보강 철근이나 보조보강철근이 ETAG 013에서 규정된 별도의 승인이 불필요한 최소 철근량을 초과 배치하여 실험이 수행되고 있다. 따라서, 본 논문에서는 ETAG 013 규정에 대한 올바른 이해와 실험을 위해 ETAG 013 규정에서 명시하는 하중전달실험 방법과 성능기준에 대해 고찰하고, 상용화된 PT정착구 시스템을 적용하여 고강도 콘크리트, 고장력 강연선을 변수로 한 실험체를 제작하고 하중전달실험을 수행하여 원형 정착구 시스템의 성능과 보조보강철근의 상관성을 평가하였다. 실험 결과, ETAG 013 규정이 적절한 크기 및 강도의 실험체와 파열력 보강철근을 사용하지 않으면 성능을 만족하지 않는 매우 엄격한 규정임이 확인되었으며, 보조보강철근의 양을 증가 시키는 것이 아니라 실험체의 크기를 최소치수로 한정짓지 않고 규정에 따라 15%크게 적용하는 방법으로 실험을 수행하는 것이 바람직한 것으로 평가되었다.

불연속면을 포함한 사질토 지반에서 터널 굴착에 따른 하중전이 (Load transfer mechanism due to tunnel excavation in the jointed sandy ground)

  • 이상덕;김양운
    • 한국터널지하공간학회 논문집
    • /
    • 제5권3호
    • /
    • pp.217-226
    • /
    • 2003
  • 본 연구에서는 활동성 불연속면을 포함하고 있는 모래지반에 터널을 굴착할 때에 터널 주변의 원지반에 발생되는 아칭을 규명하기 위하여 터널 상부의 토피고와 불연속면의 위치 및 각도를 변화시켜가며 모형실험을 수행하였다. 모형실험기의 중앙에 수직으로 이동이 가능한 가동판을 설치하고 모래지반 조성 후에 가동판을 강하시켜서 터널 굴착을 모형화 하였고, 토조의 바닥판에 로드셀을 부착하여, 아칭에 의한 하중전이를 측정하였다. 굴착에 의한 지표면의 침하거동은 변위측정센서를 지표면에 설치하여 측정하였으며, 실험 중에 연속사진촬영을 실시하고 지반조성시 일정한 간격으로 설치한 측점의 움직임을 관측하여 굴착에 의한 지반이완형태를 측정하였다. 본 연구 결과 터널굴착시 불연속면의 각도와 위치, 그리고 터널 상부의 토피고에 따라서 하중전이 형태와 이완영역이 변화하는 것을 확인하였으며 지반의 이완영역이 터널과 인접해 있는 불연속면을 따라 주변지반으로 점차 확대되어 가는 것을 알 수 있었다.

  • PDF

하중전이법의 간편 적용 (Simplified Application of Load Transfer Method)

  • 이승현;이수형
    • 한국산학기술학회논문지
    • /
    • 제13권5호
    • /
    • pp.2403-2407
    • /
    • 2012
  • 압축하중을 받는 말뚝의 하중-침하관계를 구하기 위한 하중전이법에서는 말뚝을 유한개의 요소로 분할하고 각각의 요소들에 대하여 말뚝주면변위와 주면 전이하중 그리고 말뚝선단변위와 선단저항력 사이의 적합조건으로부터 말뚝 요소의 단면력과 변위를 계산하게 된다. 통상적인 하중전이법에 의할 경우 모든 말뚝요소들에 대하여 하중-변위 사이의 적합조건을 만족하도록 반복계산을 수행해야 하므로 계산량이 과다한 단점이 있다. 본 연구에서는 압축하중을 받는 말뚝에 대한 미분방정식을 유한차분식으로 정식화하여 말뚝 바닥요소를 제외한 요소에 대해서는 반복계산 없이 직접 말뚝 단면력과 변위량을 계산할 수 있는 간편 계산법을 도입하였다. 간편 계산법에 의한 계산결과를 기존의 해석자료와 비교하여 보았는데 하중-침하관계와 말뚝 단면력 분포가 일치함을 알 수 있었다.

열.수분 동시이동 모델을 이용한 지하구조물 및 주변지반의 열수분성상 예측에 관한 연구 (Computational Analysis of the Heat/Moisture Characteristics and Heat Load of Underground Structures)

  • 박경순;손원득
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.901-905
    • /
    • 2008
  • This study was conducted to clarify the heat load characteristics and heat and moisture behavior of underground structures. The authors achieved this by carrying out a numerical analysis using simple heat diffusion and simultaneous heat and moisture transfer equations based on measurement data. This paper presents the results of a numerical analysis on the heat load characteristics and heat and moisture behavior of an underground basement and its surrounding ground under a condition of internal heat generation. The authors found it difficult to predict the heat behavior and heat load of the underground basement by simple heat diffusion alone. Accurate prediction of the thermal environment and heat load requires careful consideration of the influences of moisture and precipitation

  • PDF

Numerical study on the walking load based on inverted-pendulum model

  • Cao, Liang;Liu, Jiepeng;Zhang, Xiaolin;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.245-255
    • /
    • 2019
  • In this paper, an inverted-pendulum model consisting of a point supported by spring limbs with roller feet is adopted to simulate human walking load. To establish the kinematic motion of first and second single and double support phases, the Lagrangian variation method was used. Given a set of model parameters, desired walking speed and initial states, the Newmark-${\beta}$ method was used to solve the above kinematic motion for studying the effects of roller radius, stiffness, impact angle, walking speed, and step length on the ground reaction force, energy transfer, and height of center of mass transfer. The numerical simulation results show that the inverted-pendulum model for walking is conservative as there is no change in total energy and the duration time of double support phase is 50-70% of total time. Based on the numerical analysis, a dynamic load factor ${\alpha}_{wi}$ is proposed for the traditional walking load model.

공진 코일의 크기와 부하 저항이 자계 공명 무선 전력 전송 장치의 전달 효율에 주는 영향에 관한 연구 (A Study on the Effect of Resonant Coil Size and Load Resistance on the Transmission Efficiency of Magnetic Resonance Wireless Power Transfer System)

  • 박정흠
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.45-51
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed and the effect of resonant coil radius and load resistance to this system was analyzed by the circuit analysis method. As a result, the calculated transmitted-power is similar to measured one, and the coil size has a small effect to the coupling coefficients in the resonant frequency band. In addition, the fact that the calculated transmitted-power according to the source frequency is similar to measured one confirms that the circuit analysis methode in this paper is valid. The input side transmission efficiency ${\eta}_i$ including only the loss in the power transfer circuit is almost 90[%] with the large coil in the 10[cm] transfer distance, and 65[%] with the small coil in 1[cm]. The source side transmission efficiency ${\eta}_s$ is 30~40[%] at both coil when load resistance below 4.7[${\Omega}$] has been connected. Considering that the maximum ${\eta}_s$ is 50[%], this is valid in the practical applications.

전력 개폐기의 중첩 판 스프링의 충격 피로 해석 (Impact and Fatigue Analysis of Superposed Leaf Spring in Electric Power Switch)

  • 박우진;안길영;정광영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.794-797
    • /
    • 2005
  • The automatic load transfer switch (ALTS), a kind of electric power switch, typically automatically transfers electrical loads from a normal electrical power source to an emergency electrical power source upon reduction or loss of normal power source voltage. It can also automatically re-transfer the load to the normal power source when the normal voltage has been restored within acceptable limits. The transfer operation of ALTS is accomplished by a spring-driven linkage mechanism. In order to control or delay the transfer switching time, the ALTS studied in this paper uses the superposed leaf springs, which are subjected to impact leadings in contacting with electrical contacts. Therefore, to confirm whether the springs has enough mechanical endurance in ALTS, we build a finite element model of the superposed lear springs using LS-DYNA and perform the impact and fatigue analysis.

  • PDF

The Effect of the Types of Learning Material and Epistemological Beliefs in an Ill-structured Problem Solving

  • OH, Suna;KIM, Yeonsoon;KANG, Sungkwan
    • Educational Technology International
    • /
    • 제16권2호
    • /
    • pp.183-200
    • /
    • 2015
  • This study investigated the effect of learning achievements and cognitive load according to different types of presenting learning materials and epistemological beliefs (EB). Learning achievements in this study were composed by retention and transfer of ill-structured problem. A total of 80 college students participated in the study. Prior to the learning, students were guided to fill out a questionnaire regarding epistemological beliefs and a prior knowledge test. The students of each group studied with a different type of reading material: full text (FT), full text including key questions (KeyFT) and full text including a concept map (CmFT). After a session of study was finished, they were asked to complete the posttest: retention and transfer. The results showed that there was a significant difference in transfer achievements. CmFT outperformed higher scores than the other types. There was no significant difference in retention among the groups. It is strongly believed that the types of presenting learning materials may have affected the understanding of ill-structured problem solving skills. Students with sophisticated EB showed higher achievements on retention and transfer than naive-EB and mixed-EB. Even though the data showed decrease of the cognitive load on the type of materials and EB, there were no significant differences on the cognitive load. We should consider a positive effect of types of presenting learning materials and EB enhancing capabilities of solving ill-structured problems in real life.

기성말뚝의 지지력 거동해석과 시공관리방안 (Bearing Capacity and Control Method of Driven Piles)

  • 박영호;김경석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.249-258
    • /
    • 1999
  • Dynamic load and static load tests are performed on steel pipe piles and concrete piles at five construction sites in highway to compare the difference of load bearing mechanisms. At each site, one steel pile is instrumented with electric strain gages and dynamic tests are performed on the pile during installation. Damages of strain gages due to the installation are checked and static test is performed upon the same pile after two or seven days as well. It shows that load transfer from side friction to base resistance behaves somewhat differently according to the results of load-settlement analysis obtained from PDA and static load test. Initial elastic stage of load settlement curves of two load tests is almost similar. But after the yielding point, dynamic resistance of pile behaves more stiffer than static resistance, thus, dynamic load test result might overestimate the real pile capacity compared with static result. Analysis of gage readings shows that unit skin friction increases exponentially with depth. The skin friction is mobilized at the 1∼2m above the pile tip and contributes to the considerable side resistance. Comparison of side and base resistances between the measured value and the calculated value by Meyerhof's bearing capacity equation using SPT N value shows that the calculated base resistance is higher than the measured. Therefore, contribution of side resistance to total capacity shouldn't be ignored or underestimated. Finally, based upon the overall test results, a construction control procedure is suggested.

  • PDF