• Title/Summary/Keyword: Load Tracking

Search Result 435, Processing Time 0.031 seconds

V/f Tracking Control for Energy Saving (Energy Saving을 위한 V/f 추종제어)

  • Shin, Woo-Seok;Choe, Jae-Young;Lee, Don-Si;Choe, Gyu-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.728-730
    • /
    • 1993
  • This paper describes a simple but effective V/F control method for energy saving of a special-purpose Induction motor driven by PWM inverter. The proposed method is based on efficiency control with no speed sensor that the V/F patterns could be changed to load variations. The experimental results shows great improvement of both efficiency and power factor and usefulness of the method.

  • PDF

A Study on the LCD Backlight Drive using Piezoelectric Transformer (압전 변압기를 이용한 LCD Backlight 구동에 관한 연구)

  • 강태구;이동균;유영한;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.273-277
    • /
    • 1999
  • A cold cathode flourescent lamp for the backlight in the notebook computer requires high input voltage about 1300(V) when it turns on. But once a discharge starts, the input voltage can be dropped by about one-third for continued output. The equivalent impedance also varies from open to several dozens of kilo-ohms. The piezoelectric transformer converts electrical energy into mechanical energy and then converts it back to electrical energy at a high voltage. Its high output voltage, high efficiency and small size are suitable for driving the LCD backlight in the notebook computer. The piezoelectric transformer operates near the resonance frequency and the output waveform is close to sine wave with very little noise. This paper suggests an inverter for LCD backlight of notebook computer using piezoelectric transformer that includes voltage to frequency converter for gate signal which is useful for tracking of variable resonance frequency depending on load impedance.

  • PDF

Robust Voltage Controller of Single-Phase Inverter for UPS (무정전전원장치용 단상인버터의 강인한 전압제어기)

  • Ku, Dae-Kwan;Ji, Jun-Keun;Cha, Gueesoo;Moon, Jun-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2010.11a
    • /
    • pp.298-299
    • /
    • 2010
  • In this paper a robust voltage controller of single-phase inverter for UPS is presented. The voltage controller is designed using ${\mu}-based$ robust control scheme to simultaneously guarantee robust stability and robust tracking performance in presence of filter and load parameter variations. Firstly the robust performance of the resulting controller is theoretically confirmed via ${\mu}-analysis$. Then simulation results for single-phase inverter system with linear and nonlinear loads demonstrate feasibility of the proposed control method providing improved performance - good regulation and fast dynamic response.

  • PDF

A Efficient MPPT Control Algorithm for LED Street Lighting System using Photovoltaic Systems (태양광을 이용한 LED가로등 시스템을 위한 효율적인 MPPT 충전제어 알고리즘)

  • Kim, Byun-gon;Jeong, Dong-su
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.675-676
    • /
    • 2014
  • Photovoltaic (PV) systems bosed on solar energy offer an environmentally friendly source of electricity. A key feature of such PV sysem is the efficiency of conversion at which the power converter stage can extract the energy from the PV arrays and deliver to the load. The Maximum power point tracking (MPPT) of the PV output for all sunshine conditions allows reduction of the cost installation and maximizes the power output from the PV panel. The proposed algorithm is to control the width of the pulse for battery charging based on the open voltage of the PV panel. As a lab results, the proposed system was implemented functions to adapt to the changes of the PV open voltage, and improved the charging efficiency.

  • PDF

Crack analysis of reinforced concrete members with and without crack queuing algorithm

  • Ng, P.L.;Ma, F.J.;Kwan, A.K.H.
    • Structural Engineering and Mechanics
    • /
    • v.70 no.1
    • /
    • pp.43-54
    • /
    • 2019
  • Due to various numerical problems, crack analysis of reinforced concrete members using the finite element method is confronting with substantial difficulties, rendering the prediction of crack patterns and crack widths a formidable task. The root cause is that the conventional analysis methods are not capable of tracking the crack sequence and accounting for the stress relief and re-distribution during cracking. To address this deficiency, the crack queuing algorithm has been proposed. Basically, at each load increment, iterations are carried out and within each iteration step, only the most critical concrete element is allowed to crack and the stress re-distribution is captured in subsequent iteration by re-formulating the cracked concrete element and re-analysing the whole concrete structure. To demonstrate the effectiveness of the crack queuing algorithm, crack analysis of concrete members tested in the literature is performed with and without the crack queuing algorithm incorporated.

A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF

A study on simulation and performance improvement of industrial robot manipulator controller using adaptive model following control method (적응모델추종제어기법에 의한 산업용 로봇 매니퓰레이터 제어기의 성능개선 및 시뮬레이션에 관한 연구)

  • 허남수;한성현;이만형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.463-477
    • /
    • 1991
  • This study proposed a new method to design a robot manipulator control system capable of tracking the trajectories of joint angles in a reasonable accuracy to cover with actual situation of varying payload, uncertain parameters, and time delay. The direct adaptive model following control method has been used to improve existing industrial robot manipulator control system design. The proposed robot manipulator controller is operated by adjusting its gains based on the response of the manipulator in such a way that the manipulator closely matches the reference model trajectories predefined by the designer. The manipulator control system studied has two loops: they are an inner loop on adaptive model following controller to compensate nonlinearity in the manipulator dynamic equation and to decouple the coupling terms and an outer loop of state feedback controller with integral action to guarantee the stability of the adaptive scheme. This adaptation algorithm is based on the hyperstability approach with an improved Lyapunov function. The coupling among joints and the nonlinearity in the dynamic equation are explicitly considered. The designed manipulator controller shows good tracking performance in various cases, load variation, parameter uncertainties. and time delay. Since the proposed adaptive control method requires only a small number of parameters to be estimated, the controller has a relatively simple structure compared to the other adaptive manipulator controllers. Therefore, the method used is expected to be well suited for a high performance robot controller under practical operation environments.

Evaluation of TDF ash as a Mineral Filler in Asphalt Concrete (TDF ash를 채움재로 사용한 아스팔트 콘크리트 물성 평가)

  • Choi, MinJu;Lee, JaeJun;Kim, HyeokJung
    • International Journal of Highway Engineering
    • /
    • v.18 no.4
    • /
    • pp.29-35
    • /
    • 2016
  • PURPOSES : The new waste management policy of South Korea encourages the recycling of waste materials. One material being recycled currently is tire-derived fuel (TDF) ash. TDF is composed of shredded scrap tires and is used as fuel in power plants and industrials plants, resulting in TDF ash, which has a chemical composition similar to that of the fly ash produced from coal. The purpose of this study was to evaluate the properties of an asphalt concrete mix that used TDF ash as the mineral filler. METHODS : The properties of the asphalt concrete were evaluated for different mineral filler types and contents using various measurement techniques. The fundamental physical properties of the asphalt concrete specimens such as their gradation and antistripping characteristics were measured in accordance with the KS F 3501 standard. The Marshall stability test was performed to measure the maximum load that could be supported by the specimens. The wheel tracking test was used to evaluate the rutting resistance. To investigate the moisture susceptibility of the specimens, dynamic immersion and tensile strength ratio (TSR) measurements were performed. RESULTS : The test results showed that the asphalt concrete containing TDF ash satisfied all the criteria listed in the Guide for Production and Construction of Asphalt Mixtures (Ministry of Land, Infrastructure and Transport, South Korea). In addition, TDF ash exhibited better performance than that of portland cement. The Marshall stability of the asphalt concrete with TDF ash was higher than 7500 N. Further, its dynamic stability was also higher than that listed in the guide. The results of the dynamic water immersion and the TSR showed that TDF ash shows better moisture resistance than does portland cement. CONCLUSIONS : TDF ash can be effectively recycled by being used as a mineral filler in asphalt, as it exhibits desirable physical properties. The optimal TDF ash content in asphalt concrete based on this study was determined to be 5%. In future works, the research team will compare the characteristics of asphalt concrete as function of the mineral filler types.

An Improved MPPT Converter with Current Compensation Method for Small Scaled PV-Applications (소규모 태양광 발전시스템을 위한 전류보상기법을 갖는 향상된 MPP 추적 컨버터)

  • 이동윤;노형주;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.143-150
    • /
    • 2003
  • An improved MPPT converter with current compensation method for small-scaled PV-applications is presented in this paper. The proposed method implements maximum power point tracking (MPPT) by variable reference current which is continuously changed during one sampling period. Therefore, the Power transferred to the load is increased above 9% by the proposed MPPT converter with current compensation method. As a result, the utilization efficiency of Photovoltaic (PV)-panel can be increased. In addition, as it doesn't use digital signal processor (DSP), this MPPT method has the merits of both a cost efficiency and a simple control circuit design. Therefore, it is considered that the proposed MPPT method is proper to low power, low cost PV-applications. The concept and control principles of the proposed Un moth()d are explained in detail and its validity of the proposed method is verified through several simulated results.

Design and Implementation of Modified Current Source Based Hybrid DC - DC Converters for Electric Vehicle Applications

  • Selvaganapathi, S.;Senthilkumar, A.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.2
    • /
    • pp.57-68
    • /
    • 2016
  • In this study, we present the modern hybrid system based power generation for electric vehicle applications. We describe the hybrid structure of modified current source based DC - DC converters used to extract the maximum power from Photovoltaic (PV) and Fuel Cell system. Due to reduced dc-link capacitor requirement and higher reliability, the current source inverters (CSI) better compared to the voltage source based inverter. The novel control strategy includes Distributed Maximum Power Point Tracking (DMPPT) for photovoltaic (PV) and fuel cell power generation system. The proposed DC - DC converters have been analyzed in both buck and boost mode of operation under duty cycle 0.5>d, 0.5<d<1 and 0.5<d for capable electric vehicle applications. The proposed topology benefits include one common DC-AC inverter that interposes the generated power to supply the charge for the sharing of load in a system of hybrid supply with photovoltaic panels and fuel cell PEM. An improved control of Direct Torque and Flux Control (DTFC) based induction motor fed by current source converters for electric vehicle.In order to achieve better performance in terms of speed, power and miles per gallon for the expert, to accepting high regenerative braking current as well as persistent high dynamics driving performance is required. A simulation model for the hybrid power generation system based electric vehicle has been developed by using MATLAB/Simulink. The Direct Torque and Flux Control (DTFC) is planned using Xilinx ISE software tool in addition to a Modelsim 6.3 software tool that is used for simulation purposes. The FPGA based pulse generation is used to control the induction motor for electric vehicle applications. FPGA has been implemented, in order to verify the minimal error between the simulation results of MATLAB/Simulink and experimental results.