• 제목/요약/키워드: Load Pressure Feedback Chamber

검색결과 3건 처리시간 0.019초

CO2냉매용 제어밸브의 응답 특성 (Transient Response Analysis of a Control Valve for CO2 Refrigerant)

  • 김보현;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제15권4호
    • /
    • pp.11-16
    • /
    • 2018
  • Pilot operated control valve for $CO_2$ refrigerant is a valve that can perform various functions according to the user's intention by replacing pilot units, widely used for flow rate, pressure, and temperature control of refrigeration and air conditioning systems. In addition, $CO_2$ refrigerant, that requires high pressure and low critical temperature, can be installed and used in all positions of the refrigeration system, regardless of high or low pressure. In this paper, response characteristics are modeled and analyzed based on behavior of the main piston of the pilot-operated control valve. Although various factors influence operation of the main piston, this paper analyzes the effect of equilibrium pressure depending on valve installation position and application, and inlet and outlet orifice size of the load pressure feedback chamber to determine feedback characteristics of the main piston. As a result, it was possible to quantitatively analyze the effect of change in equilibrium and load pressure feedback chamber flow path size on the change in main piston dynamic and static characteristics.

비례압력제어밸브의 부하압력 피드백방법 개선에 관한 연구 (A Study on the Improvement of the Load Pressure Feedback Mechanism of the Proportional Pressure Control Valve)

  • 오인호;장지성;이일영;정대종;조성현
    • 대한기계학회논문집A
    • /
    • 제21권5호
    • /
    • pp.719-726
    • /
    • 1997
  • The proportional pressure control valve having versatile functions and higher performance is an essential conponent in the open loop controlled rear wheel steering gear of the four wheel steering system in a passenger car. In this study, the authors suggest a new type of load pressure feedback mechanism which can make it easy to change the range of controlled pressure without changing the capacity of solenoid. The concept of suggested mechanism, composed of the pressure chamber with throttles in series, was described. The mathematical model was derived from the rear wheel steering gear consisting of a valve and a cylinder for the purpose of analyzing the valve characteristics. And the programme for computing the characteristic of the valve was developed. Experiments were performed to confirm the performance of the valve and computations were carried out to ascertain the usefulness of the developed programme. The results from computations fairly coincide with those from experiments. And the results from experiments and computations show that the performance of new valve was as good as that of the already developed one and the new valve has advantages such as the easiness of changing the range of controlled pressure and the decrease of power loss at neutral position without the decline of performance.

비대칭 이중화 EHA의 동기 제어 (Synchronous Control of an Asymmetrical Dual Redundant EHA)

  • 이성렬;홍예선
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권2호
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper, an elementary force fighting problem was investigated. The problem is encountered when a double-rod type EHA(electro-hydrostatic actuator) is combined with a single-rod type EHA to build a redundant actuator system with synchronized motion. When the rod-side chambers of the two different types of EHAs have the same effective piston areas and are simultaneously pressurized by an external load, the two EHAs behave identically, sharing the external load equally. However, when the piston head-side chamber of the single rod type EHA, having a larger effective area than the rod-side chamber, is pressurized by the external load, an abnormal force fighting between the two EHAs occurs, unless their pump speeds are properly decoupled. In this study, the output drive forces of each EHA were obtained from the cylinder pressure signals and applied to the position control for each EHA to maintain the balance between their pump speeds. Adding minor force difference feedback loops to the position control, the force fighting phenomena could be eliminated and steady state synchronization errors were reduced. The power consumption of the pumps also could be remarkably reduced, avoiding unnecessarily high load pressures to the pumps.