• 제목/요약/키워드: Load Power Factor

검색결과 847건 처리시간 0.041초

스마트 마이크로그리드 실시간 상태 추정에 관한 연구 (A Study on Real-time State Estimation for Smart Microgrids)

  • 배준형;이상우;박태준;이동하;강진규
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.419-424
    • /
    • 2012
  • This paper discusses the state-of-the-art techniques in real-time state estimation for the Smart Microgrids. The most popular method used in traditional power system state estimation is a Weighted Least Square(WLS) algorithm which is based on Maximum Likelihood(ML) estimation under the assumption of static system state being a set of deterministic variables. In this paper, we present a survey of dynamic state estimation techniques for Smart Microgrids based on Belief Propagation (BP) when the system state is a set of stochastic variables. The measurements are often too sparse to fulfill the system observability in the distribution network of microgrids. The BP algorithm calculates posterior distributions of the state variables for real-time sparse measurements. Smart Microgrids are modeled as a factor graph suitable for characterizing the linear correlations among the state variables. The state estimator performs the BP algorithm on the factor graph based the stochastic model. The factor graph model can integrate new models for solar and wind correlation. It provides the Smart Microgrids with a way of integrating the distributed renewable energy generation. Our study on Smart Microgrid state estimation can be extended to the estimation of unbalanced three phase distribution systems as well as the optimal placement of smart meters.

  • PDF

2.25Cr1Mo강의 크리프 손상에 대한 초음파 시험평가 (Ultrasonic Evaluation for the Creep Damage of 2.25Cr1Mo Steel)

  • 허광범;이인철;정계조;조용상;이상국;김재훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.31-36
    • /
    • 2000
  • High temperature and pressure materials in power plant are degraded by creep damage, if they are exposed to constant loads for long times, which occurs in the load bearing structures of pressurized components operating at elevated temperatures. Many conventional measurement techniques such as replica method, electric resistance method, and hardness test method for measuring creep damage have been used. So far, the replica method is mainly used for the Inspection of High temperature and pressure components. This technique is, however, restricted to applications at the surface of the testpieces and cannot be used to material inside. In this paper, ultrasonic evaluation for the detection of creep damage in the form of cavaties on grain boundaries or integranular microcracks are carried out. And the absolute measuring method of quantitative ultrasonic velocity technique for Cr-Mo material degradation is analyzed. As a result of ultrasonic tests for crept specimens, we find that the sound velocity is decreased as the increase of creep life fraction$({\Phi}_c)$ and also, confirmed that hardness is decreased as the increase of creep life fraction$({\Phi}_c)$ but the coefficient of ultrasonic attenuation is increased as the increase of creep life fraction$({\Phi}_c)$. Finally based on the result in this paper, it can be recognized that the ultrasonic techniques using velocities and attenuation coefficient factor are very useful non-destructive methods to evaluate the degree of material degradation in fossile power plants.

  • PDF

병원내 온도와 습도조절을 위한 태양광 발전 시스템 설계 (Photovoltaic Generation System Design for Controlling the Temperature and Humidity of Hospital)

  • 조문택;이충식;백종무
    • 한국방사선학회논문지
    • /
    • 제5권3호
    • /
    • pp.127-134
    • /
    • 2011
  • 본 논문에서는 온도와 습도 및 냉 난방을 조절하여 건물 내의 쾌적한 환경을 제공하기 위한 승압쵸퍼와 PWM 전압형 인버터로 구성된 태양광 발전 시스템을 제안하였다. 이 시스템은 안정된 변조를 위해 원칩 마이크로프로세서를 사용하여 동기신호와 제어신호로 처리하였다. PWM 전압형 인버터와 위상의 동기를 위하여 계통전압을 검출하여 계통전압과 인버터 출력을 동상 운전하므로 잉여전력을 연계할 수 있게 하였으며, 건물이나 병원 등 특정 건물의 온도 및 습도센서에 적용하여 양호한 동특성을 얻을 수 있었다. 또한 시스템에 적용한 결과 고역률과 저고조파 출력을 유지함으로써 부하와 계통에 전력이 안정하게 공급될 수 있도록 제어하여 좋은 결과를 얻을 수 있었다.

비접촉 전원장치에 적용한 LCC형 고주파 공진 DC/DC 컨버터에 관한 연구 (A Study on the LCC Type High Frequency DC/DC Converter for Contactless Power Supply System)

  • 김동희;황계호
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.55-64
    • /
    • 2007
  • 본 논문은 부하직렬 고주파 공진 DC/DC 컨버터에 가변 가능한 공진커패시터를 병렬로 삽입한 LCC형 고주파 공진 DC/DC 컨버터의 특성과 설계 예를 나타내고 있으며, 또한 턴-오프시 스위칭 손실을 줄이기 위해 ZVS를 가지는 소프트 스위칭을 사용하였다. 제안 컨버터는 PFM(Pulse Frequency Modulation) 스위칭 패턴을 사용하여 동작되며, PFM 제어에 의해 제안 회로의 출력전압을 제어하였다. 병렬커패시터의 커패시턴스의 변화에 따라, DC/DC 컨버터의 분석은 일반적으로 무차원화 파라미터를 사용하여 나타내었고, 회로 동작 특성은 스위칭 주파수와 파라미터로 행하였다. 또한 본 논문은 특성평가에 의해 제안 DC/DC 컨버터의 동작 특성과 회로 설계 방법을 제시하였다. 더욱이 본 논문은 실험을 통해 이론 분석의 정당성을 입증하였다. 향후 제안한 DC/DC 컨버터는 반도체 및 FPD의 클린룸에 선형이동 시스템의 비접촉 전원장치에 적용 가능하다고 생각된다.

전압 불평형시 콘덴서 전압, 전류, 용량 특성 해석 (Characteristics Analysis for Voltage, Current & Capacity of Condenser at Voltage Unbalance)

  • 김종겸;박영진
    • 조명전기설비학회논문지
    • /
    • 제24권5호
    • /
    • pp.145-151
    • /
    • 2010
  • 전압 불평형은 수용가 설비에서 상당히 중요한 전기 품질의 하나로 간주되고 있다. 전압은 송전선로 계통에서는 평형에 가깝지만, 수용가에서의 전압 레벨은 시스템 임피던스의 불평형과 단상 부하의 고르지 못한 배분 등으로 인해 불평형이 될 수 있다. 콘덴서는 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터와 함께 사용되고 있다. 전압 불평형이 존재할 경우 전류 불평형으로 콘덴서에서는 용량변화가 일어난다. 콘덴서와 리액터를 함께 사용하는 경우 사고 발생이 높은 편이다. 그래서 콘덴서 설비에 전압 불평형이 존재할 경우 전압, 전류 그리고 용량의 변화가 어떻게 진행되는지 확인하는 것이 매우 중요하다. 본 연구에서는 전압 불평형률이 존재할 경우 콘덴서 단독운전과 리액터의 부착시 전압, 전류 및 용량의 크기가 규정에서 제시한 범위 이내인지를 계산하였다.

Optimal Location of FACTS Devices Using Adaptive Particle Swarm Optimization Hybrid with Simulated Annealing

  • Ajami, Ali;Aghajani, Gh.;Pourmahmood, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.179-190
    • /
    • 2010
  • This paper describes a new stochastic heuristic algorithm in engineering problem optimization especially in power system applications. An improved particle swarm optimization (PSO) called adaptive particle swarm optimization (APSO), mixed with simulated annealing (SA), is introduced and referred to as APSO-SA. This algorithm uses a novel PSO algorithm (APSO) to increase the convergence rate and incorporate the ability of SA to avoid being trapped in a local optimum. The APSO-SA algorithm efficiency is verified using some benchmark functions. This paper presents the application of APSO-SA to find the optimal location, type and size of flexible AC transmission system devices. Two types of FACTS devices, the thyristor controlled series capacitor (TCSC) and the static VAR compensator (SVC), are considered. The main objectives of the presented method are increasing the voltage stability index and over load factor, decreasing the cost of investment and total real power losses in the power system. In this regard, two cases are considered: single-type devices (same type of FACTS devices) and multi-type devices (combination of TCSC, SVC). Using the proposed method, the locations, type and sizes of FACTS devices are obtained to reach the optimal objective function. The APSO-SA is used to solve the above non.linear programming optimization problem for better accuracy and fast convergence and its results are compared with results of conventional PSO. The presented method expands the search space, improves performance and accelerates to the speed convergence, in comparison with the conventional PSO algorithm. The optimization results are compared with the standard PSO method. This comparison confirms the efficiency and validity of the proposed method. The proposed approach is examined and tested on IEEE 14 bus systems by MATLAB software. Numerical results demonstrate that the APSO-SA is fast and has a much lower computational cost.

250W MHL용 Buck Type 전자식 안정기 및 Dimming 시스템 개발 (The Development of Buck Type Electronic Ballast for 250W MHL and Dimming System)

  • 박종연;박영길;정동열;김한수
    • 전력전자학회논문지
    • /
    • 제7권1호
    • /
    • pp.30-40
    • /
    • 2002
  • 본 논문은 250w 메탈 할라이드 램프용 전자식 안정기의 개발에 관한 연구로써 안정기의 입력 역율은 PFC IC를 이용하여 개선하였고, 벅 Type의 DC-DC 컨버터를 회로에 삽입하여 인버터회로에서 램프의 정격전압만을 공급할 수 있도록 함으로써 인버터 스위칭소자의 스트레스를 줄이게 되었다. 인버터의 형태는 풀 브릿지로 하였고 램프 점등을 구형 저주파에 고주파 성분을 첨가하는 방식으로 음향공명현상을 제거하였다. 또한 LC 회로를 이용한 간단 한 점화기 회로를 개발하였다. 벅 컨버터의 출력 전압을 조절하여 램프의 전압이 가변되는 원리를 이용하여 조광 제어를 할 수 있으며 계절별 및 시간대별로 점등시간과 조도조절이 가능토록 하였다. 벅 컨버터 출력 전압의 조절과 무부하 보호 및 과전류 보호 기능은 마이크로프로세서의 프로그램을 개발하여 수행하였다.

운전자 작업부하를 고려한 최장 허용 직선길이 결정에 관한 연구 (A Study on Evaluating Length Limit in Tangent Section of Highway Based on Driver's Workload)

  • 정봉조;강정규;김주영;장명순
    • 대한교통학회지
    • /
    • 제20권2호
    • /
    • pp.17-26
    • /
    • 2002
  • 본 연구에서는 직선도로와 일반도로 구간을 운전하는 운전자의 각성변화비교와 적정한 도로의 직선길이를 알아보기 위하여 10명의 피실험자를 대상으로 실제 운전 중에 운전자의 좌우측 전두엽과 후두염의 뇌파를 측정하였다. 수집된 Data를 FFT(Fast Fourier Transform)분석에 대해 상대 파워스펙트럼 값을 구하였으며 $\beta$파의 값을 중심으로 분석하였다. 본 연구에서 얻은 결과를 요약하면 다음과 같다. 첫째 운전자의 각성수준 치를 측정하여 새로운 최대 허용 직선길이 기준정립에 활용가능한 방법론을 제시하였다. 둘째 직선구간을 주행하는 경우 일반구간 주행보다 각성정도가 낮은 것으로 나타났다 특히, 운전 중 운전자의 각성을 가장 잘 설명하는 것으로 알려진 후두염에서는 현저한 각성의 감소가 일어났다. 일반구간은 0.821, 직선구간은 2.219로 직선구간에서 약 3배정도의 각성치가 낮아져서 운전자의 운전능력이 현저하게 떨어지는 것으로 평가되었다. 셋째, 운전자 각성수준은 직선도로 진입 후 4.2km지점에 0.428로 나타나 통계적으로 유의한 수준으로 각성이 크게 감소되었으나 3.6km가지는 운전자의 각성수준이 유의한 수준으로 감소하지 않고 있다. 넷째 따라서 20~30대 남성을 대상으로 한 실험조건에서 직선구간의 최장 허용 길이를 기존의 설계속도의 20배로 규정한 2.0km 값보다는 설계속도의 30배인 3.0km로 완화하여도 운전자의 운전능력에 부정적인 영향이 없을 것으로 판단되었다.

신경회로망을 적용한 직류배전시스템의 AFE 정류기 제어에 관한 연구 (Active Front End Rectifier Control of DC Distribution System Using Neural Network)

  • 김성완;전현민;김종수
    • 해양환경안전학회지
    • /
    • 제27권7호
    • /
    • pp.1124-1128
    • /
    • 2021
  • 선박으로부터 발생하는 배출가스에 대한 규제가 강화되고 이를 해결하기위한 대안으로 전기추진시스템의적용이 대형상선에서부터 중·소형선박에 이르기까지 그 사용이 증가되고있다. 전기추진시스템의 효율 향상을 위한 방법으로 발전원의 개선, 배터리·연료전지·태양광 등의 친환경 발전원의 시스템 연계 및 정류기, 전력변환장치, 추진전동기의 개발과 제어방식의 연구를 들 수 있다. 그 중 정류방식에 있어 상천이변압기과 다이오드를 이용하는 방식이 널리 사용되었으나, 직류배전을 이용한 친환경발전원의 계통 연계, 가변속 발전원의 사용, 중·소형 전기추진시스템의 적용을 통해 전력용 반도체 소자를 이용한 AFE정류기에 대한 수요가 증대되고 있다. 이러한 AFE 정류기를 제어하는 방식에 있어 기존의 비례적분제어기가 아닌 신경회로망을 이용한 방식을 본 연구에서는 제안하였다. 기존의 제어기 데이터를 활용하여 Matlab/Simulink를 통해 학습한 신경회로망제어기를 설계하고 PSIM을 통해 설계된 정류시스템에 신경회로망 제어기를 적용하여 부하변동에 따른 직류출력단의 파형과 역률 개선의 유효성을 확인하였다. 이는 공간이 협소한 중소형 친환경 선박의 정류시스템으로써 적용이 가능하다.

계통 연계형 태양광 발전시스템의 전력변환기 제어에 관한 연구 (A Study on the Power Converter Control of Utility Interactive Photovoltaic Generation System)

  • 나승권;구기준;김계국
    • 한국컴퓨터정보학회논문지
    • /
    • 제14권2호
    • /
    • pp.157-168
    • /
    • 2009
  • 본 논문에서는 태양광 발전시스템을 이용한 승압 초퍼와 전압형 PWM(Pulse Width Modulation) 인버터인 전력변환기로 구성하였고, 안정된 변조를 위해서 동기신호와 제어신호를 원칩 마이크로프로세서에 의해서 처리하였다. 전력비교에 따라 시간 비율을 변화시키지만 태양전지는 전형적인 수하특성을 갖고 있어, 일사량과 온도변화에 관계없이 항상 최대 출력점을 추적하도록 승압초퍼를 제어하였다. 또한 PWM 전압형 인버터는 태양전지가 연속 발전할 수 없는 단점을 보완하기 위해 일반 상용전원과 연계함으로써 약 $10{\sim}20[%]$ 전력절감효과를 얻을 수 있는 에너지절약 전원 복합형 전력변환장치로 구성하였다. 그리고 태양광 발전의 효율을 높이기 위하여 센서와 마이크로프로세서를 이용한 태양광위치추적 장치를 설계하여 고정방식의 태양광 발전에 대하여 비교해 보았다. 그 결과, 태양광 위치추적장치는 고정방식의 태양광 발전에 비해 5% 정도 개선됨을 알 수 있었다. 또한, PWM 전압형 인버터와 위상동기를 위해서 계통전압을 검출하여 계통전압과 인버터 출력을 동상 운전하므로 잉여전력을 계통과 연계할 수 있게 하였다. 그리고 고역율과 저고조파 출력을 유지함으로서 부하와 계통에 전력이 안정하게 공급될 수 있도록 제어하였다.