• 제목/요약/키워드: Load Power Factor

검색결과 844건 처리시간 0.034초

Design Considerations for a Distributed Generation System Using a Voltage-Controlled Voltage Source Inverter

  • Ko, Sung-Hun;Lee, Su-Won;Lee, Seong-Ryong;Naya, Chemmangot V.;won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.643-653
    • /
    • 2009
  • Voltage-controlled voltage source inverter (VCVSI) based distributed generation systems (DGS) using renewable energy sources (RES) is becoming increasingly popular as grid support systems in both remote isolated grids as well as end of rural distribution lines. In VCVSI based DGS for load voltage stabilization, the power angle between the VCVSI output voltage and the grid is an important design parameter because it affects not only the power flow and the power factor of the grid but also the capacity of the grid, the sizing of the decoupling inductor and the VCVSI. In this paper, the steady state modeling and analysis in terms of power flow and power demand of the each component in the system at the different values of maximum power angle is presented. System design considerations are examined for various load and grid conditions. Experimental results conducted on a I KVA VCVSI based DGS prove the analysis and simulation results.

A Critique of Designing Resource Adequacy Markets to Meet Loss of Load Probability Criterion

  • Yoon, Yong T.;Felder, Frank A.
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.35-41
    • /
    • 2003
  • To ensure resource adequacy in restructured electricity markets, policymakers have adopted installed capacity (ICAP) markets in some regions of the United States. These markets ensure that adequate generation exists to satisfy regional Loss of Load Probability(LOLP) criterion. Since the incentives created through ICAP mechanisms directly impact new generation and transmission investment decisions we examine one important factor that links ICAP markets with LOLP calculations;, determining the amount of ICAP credit assigned to particular generation units. First, we review and critique the literature on electric power systems' market failure resulting from demand exceeding supply. We then summarize the method of computing (the LOLP) as a means of assessing reliability and relate this method to ICAP markets. We find that only the expected value of available generation is used In current ICAP markets while ignoring the second and higher order moments, which tends to mis-state the ICAP value of a specific resource. We then consider a proposal whose purpose is to avoid this ICAP assignment issue by switching from ICAP obligations to options. We find that such a proposal may fail to not provide the benefits claimed and suffers from several practical difficulties. Finally, we conclude with some policy recommendations and areas for future research.

DC전압 충전 및 전원 역률 보상이 가능한 APF에 관한 연구 (A study on Active Power Filter Available for DC-Link Boost and Power Factor Control)

  • 이우철
    • 조명전기설비학회논문지
    • /
    • 제27권1호
    • /
    • pp.53-60
    • /
    • 2013
  • In this paper, a control algorithm for active power filter (APF), which compensates for the harmonics and power factor, boosting the DC-link voltage is proposed. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter. A simple algorithm to detect the load current harmonics is also proposed. The APF and charging circuit are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF system rated at 3kVA.

Analysis and Design of Sliding Mode Control for a Single-Phase AC-DC Converter

  • Sawaengsinkasikit, Winyu;Tipsuwanporn, Vittaya;Tarasantisuk, Chanlit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2291-2294
    • /
    • 2003
  • In this paper, analysis and control design of ac-dc converter, normally nonlinear time-varying system, using sliding mode controller to achieve fast output voltage response, disturbance rejection and robust system in the presence of load variation are demonstrated. The objective of this method is to develop methodology for output voltage to be constant and input current sinusoidal that results in nearly unity power factor, respectively. In addition the converter can be also bidirectional power flow. Simulation results using Matlab/Simulink show the effectiveness of sliding mode control system compared with linear feedback controller to guarantee enhanced PF>0.98, THD<5%, and ripple output voltage is less than 1% at the maximum output power.

  • PDF

단위역률 정류기의 병렬운전 (Parallel operation of rectifier with unit-power factor)

  • 이성희;김태원;박재욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1212-1213
    • /
    • 2011
  • PWM(pulse width modulation) rectifier has unit power factor and low harmonic distortion with high power conversion efficiency in entire loading range. These merits of PWM rectifier help the spread of DC distribution system. In addition, if multiple PWM rectifiers can be operated in parallel connection, maintenance process can be simple and reliability of power source can be advanced because of the hot swapping is available. The other way, the load unbalance among rectifiers can force a converter to stop by over current. The surge current by closed circuit composition between rectifiers can force switching devices damage. In this paper, some problems that can occur in case of parallel operation of PWM rectifiers and problem eliminating methods are considered.

  • PDF

단일 스위치 3상 ZCS 강압형 정류기의 펄스 주파수 제어 (A Pulse Frequency Control of Single-switch Three-phase ZCS Buck Rectifiers)

  • 송중호;김용덕;이동윤;최익;최주엽;유지윤
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.82-90
    • /
    • 1999
  • 본 논문은 단일 스위치 3상 ZCS 강압형 정류기의 펄스주파수 제어기법을 다루고 있다. 제안하는 펄스주파수 제어방법은 거의 정현적인 입력전류를 흐르게 하여 3상 강압형 정류기의 성능을 보여준다. 제안하는 제어구조의 유용성을 검증해 주는 시뮬레이션과 실험 결과는 단일 스위치 3상 ZCS 강압형 정류기의 고역율, 입력전류의 낮은 THD, 부하 변동에 대한 전압의 응답특성들이 뛰어남을 보여준다.

Implementation of Digital Control for Critical Conduction Mode Power Factor Correction Rectifier

  • Shin, Jong-Won;Baek, Jong-Bok;Cho, Bo-Hyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.147-148
    • /
    • 2011
  • In this paper, implementation of digital control for critical conduction mode power factor correction (PFC) rectifier is presented. Critical conduction mode is widely used in medium and low power conversion application due to its minimized MOSFET turn-on loss and diode reverse-recovery problem. However, it needs additional zero current detection circuit and maximum frequency limit to properly turn the MOSFET on and avoid the excessive switching loss in light load operation. This paper explains the digital IC implementation and verifies its operation with 200-W prototype PFC rectifier.

  • PDF

경제성을 고려한 보조전원장치의 컨버터 입력전압 추정을 위한 제어기 설계 (A Controller Design for SIV with Converter Derived Input Voltage for Consideration Economic Efficiency)

  • 김재문;안정준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1131-1136
    • /
    • 2008
  • The single-phase PWM converter employing power semiconductors is currently applied to the power unit of high-speed rail vehicle and increasingly used as the front-end converter with properties of near unity power factor. Power factor and harmonics are increasingly important needs for drive system of high-speed rail vehicle. The proposed approach has many advantages which include fewer semiconductor components, simplified control, high performance features and satisfies IEC 555 harmonic current standards. Simulation results show that the dc-link voltage control obey the reference value during constant load and input current is near sinusoidal.

  • PDF

직류링크 전해커패시터 없는 AC-DC-AC 컨버터 재어에 관한 연구 (New Control Seheme for AC-DC-AC Converters without DC Link Electrolytic Capacitor)

  • 김준석;설승기
    • 대한전기학회논문지
    • /
    • 제43권3호
    • /
    • pp.397-408
    • /
    • 1994
  • In this paper, a novel concept for a static three-phase to three-phase power converter for an AC drive with a unity power factor and reduced harmonics on the utility line is presented. The power circuit consists of two back-to-back connected six-pulse bridges having only a $\mu$F ceramic capacitor in the DC link. By controlling the active kpower balance between two bridges, the DC link voltage can be maintained within 20V deviation from the nominal value with the small ceramic capacitors regardless of the load variation even in the unbalanced source condition.

  • PDF

일반용전력사용고객 용도별 부하특성을 고려한 변압기최대이용률 비교 특성 연구 (A Study on Characteristic for a Maximum Utilization Factor of Transformer with Regard to Load Characteristics in General Customers)

  • 김세동;왕용필;홍현문
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.217-223
    • /
    • 2009
  • 계약전력 산정 방법에서 계약전력 환산율은 전력용변압기의 용량을 산정하는데 매우 중요한 기준이다. 본 연구에서는 AMR(자동검침시스템) 시스템에 의해 일반용전력사용고객(사무실, 상가, 호텔, 병원, 예식장, 기타)을 대상으로 각 수용가의 계약전력과 최근 5년 동안의 최대전력을 조사하였다. 조사된 자료의 전체 특징과 중심적인 경향을 알아 보기 위해서 평균값 등의 특징파라미터를 분석하였고, 회귀분석을 통한 선형적인 방법과 비선형적인 방법으로 그 경향을 분석하였다. 계약전력환산율과는 용도별로 다른 특성을 나타내고 있음을 확인하였으며, 전기사용고객의 특성을 고려한 계약종별 기준에 대한 체계적인 검토가 필요하다.