Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

  • Obais, Abdulkareem Mokif;Pasupuleti, Jagadeesh
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.742-753
    • /
    • 2014
  • In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is connected to an AC source via a series first harmonic filter. The harmonic-suppressed TCR is designed so that negligible harmonic current components are injected into the AC source. The compensator is equipped with a new adaptive closed loop current controller, which responds linearly to reactive current demands. The no load operating losses of this compensator are negligible when compared to its capacitive reactive current rating. The proposed system is validated on PSpice which is very close in terms of performance to real hardware.

Effect of Load Modeling on Low Frequency Current Ripple in Fuel Cell Generation Systems

  • Kim, Jong-Soo;Choe, Gyu-Yeong;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권2호
    • /
    • pp.307-318
    • /
    • 2010
  • In this work, an accurate analysis of low frequency current ripple in residential fuel cell power generation systems is performed based on the proposed residential load model and its unique operation algorithm. Rather than using a constant dc voltage source, a proton exchange membrane fuel cell (PEMFC) model is implemented in this research so that a system-level analysis considering the fuel cell stack, power conditioning system (PCS), and the actual load is possible. Using the attained results, a comparative study regarding the discrepancies of low frequency current ripple between a simple resistor load and a realistic residential load is performed. The data indicate that the low frequency current ripple of the proposed residential load model is increased by more than a factor of two when compared to the low frequency current ripple of a simple resistor load under identical conditions. Theoretical analysis, simulation data, and experimental results are provided, along with a model of the load usage pattern of low frequency current ripples.

유도전동기 역률 보상 파라미터의 적정성 검토 (Suitability Review for Power Correction Parameter of Induction Motor)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제22권12호
    • /
    • pp.101-109
    • /
    • 2008
  • 유도전동기는 회전에 필요한 자계를 유지하기 위해 무효전력을 필요로 한다. 만일 전원측을 대신하여 부하측에서 무효전력이 제공될 경우 역률은 향상될 것이다. 유도전동기의 역률은 대개 낮으므로 커패시터로 보상이 필요하다. 내선규정에서 유도전동기의 역률 보상 커패시터의 용량은 출력에 따라 추천된 값의 설치를 권고하고 있다. 그러나 유도전동기는 같은 출력에서도 회전수에 따라 특성이 달라지므로 역률이 일정하지 않아 용량에 따라 일정한 커패시터의 적용은 부적합하다. 그래서 본 논문에서는 같은 출력조건에서 속도에 따라 기존에 제시된 값과 비교한 결과 역률 보상 커패시터의 용량이 약간 높게 설정되어야 함을 확인하였다.

두 개의 Quasi Z-소스 AC-AC 컨버터에 의한 6.6[kV]/60[Hz] 배전계통의 동적 전압 보상기(DVR) (Dynamic Voltage Restorer (DVR) for 6.6[kV]/60[Hz] Power Distribution System Using Two Quasi Z-Source AC-AC Converters)

  • 엄준현;정영국;임영철;최준호
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.199-208
    • /
    • 2012
  • This paper proposes a quasi Z-source DVR(Dynamic Voltage Restorer) system with a series connection of the output terminals, to compensate the voltage variations in the 6.6[kV]/60[Hz] power distribution system. The conventional DVR using one quasi Z-source AC-AC converter has the advantage which it can compensate the voltage variations without the need for the additional energy storage device such as a battery, but it is impossible to compensate for the 50[%] under voltage sags. To solve this problem, a DVR system using two quasi Z-source AC-AC converters with the series connection of the output terminals is proposed. By controlling the duty ratio D in the buck-boost mode, the proposed system can control the compensation voltage. For case verification of the proposed system, PSIM simulation is achieved. As a result, in case that the voltage sags-swells occur 10[%], 20[%], 60[%] in power distribution system, and, in case that the 50[%] under voltage sags-swells continuously occur, all case could compensate by the proposed system. Especially, the compensated voltage THD was examined under the condition of the 10[%]~50[%] voltage sags and the 20[${\Omega}$]~100[${\Omega}$] load changes. The compensated voltage THD was worse for the higher load resistances and more severe voltage sags. Finally, In case of the voltage swells compensation, the compensation factor has approached nearly 1 regardless of the load resistance changes, while the compensation factor of voltage sags was related to the load variations.

태양광 발전시스템을 위한 단상 PWM 전압형 인버터 (A Single-phase PWM Voltage Source Inverter for Photovoltaic Generation System)

  • 유택빈;성낙규;강승욱;이승환;이훈구;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.443-445
    • /
    • 1995
  • Since the residential load is an AC load, while the output of solar cell is a DC power, the photovoltaic system needs the DC/AC converter to utilize solar cell and must provide the sinusoidal wave current and voltage with unity power factor in the case of driving to Interact with utility line. It is always necessary for the output of solar cell to operate in the vicinity of maximum power point, since it is greatly fluctuated by insolation. This paper treats that we will constitute a single phase PWM voltage source inverter and trace the modulation index which always maximize the output of solar cell in propotion to insolation variation and prove it by simulation that we can provide current wave, which is nearly sinusoidal wave with unity power factor, for load and utility line.

  • PDF

배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정 (The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System)

  • 장정태;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

Wind Energy Interface to Grid with Load Compensation by Diode Clamped Multilevel Inverters

  • Samuel, Paulson;Naik, M. Kishore;Gupta, Rajesh;Chandra, Dinesh
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.271-281
    • /
    • 2014
  • Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.

Dynamic response of size-dependent porous functionally graded beams under thermal and moving load using a numerical approach

  • Fenjan, Raad M.;Ahmed, Ridha A.;Faleh, Nadhim M.;Hani, Fatima Masood
    • Structural Monitoring and Maintenance
    • /
    • 제7권2호
    • /
    • pp.69-84
    • /
    • 2020
  • Based on differential quadrature method (DQM) and nonlocal strain gradient theory (NSGT), forced vibrations of a porous functionally graded (FG) scale-dependent beam in thermal environments have been investigated in this study. The nanobeam is assumed to be in contact with a moving point load. NSGT contains nonlocal stress field impacts together with the microstructure-dependent strains gradient impacts. The nano-size beam is constructed by functionally graded materials (FGMs) containing even and un-even pore dispersions within the material texture. The gradual material characteristics based upon pore effects have been characterized using refined power-law functions. Dynamical deflections of the nano-size beam have been calculated using DQM and Laplace transform technique. The prominence of temperature rise, nonlocal factor, strain gradient factor, travelling load speed, pore factor/distribution and elastic substrate on forced vibrational behaviors of nano-size beams have been explored.

전력시스템 적정 부하율 산정을 위한 단위당 수요관리비용 추정 방안 연구 (A Study on the Estimations Method of Demand-Side Management Cost Per kW and/or kWh to Find Reasonable Load Factor)

  • 황성욱;김정훈;정영범;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.26-28
    • /
    • 2007
  • To estimate reasonable load factor of power system both supply side and demand side of views should be considered. In the case of this study the demand side is considered and it is supposed that load curves depends on the load factor. The key point of this study is that the cost of demand-side management program per kW and/or kWh should be calculated.

  • PDF

무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계 (Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제7권1호
    • /
    • pp.30-36
    • /
    • 1993
  • 본 연구는 정류기의 입력전류에 포함되어 있는 고조파성분을 제거하고 입력역률을 개선하기 위해 무손실 저항(Loss Free Resistor) 개념에 기본을 둔, PC, 가전기기 및 형광등용 전자안정기등과 같은 저전력 전원설비에 적합한 불연속 도통모드(DCM) 플라이백 방식의 능동역률 보정기의 등가회로모델 및 설계법을 제시하였다. 이 개념에 의하여 능동역률 보정기의 등가입력저항, 출력전력원 특성을 정확하게 나타낼 수 있었으며 또 설계방정식을 유도하여 능동역률 보정기를 설계 시험한 결과, 적은 부품으로 정류기의 입력교류 전류에 포함되어 있는 고주파를 제거하였고 따라서 0.98의 고입력역률의 정류를 할 수 있었다.

  • PDF