• 제목/요약/키워드: Load Frequency Control

Search Result 795, Processing Time 0.021 seconds

Study on the Identification of Ship Maneuverability Required for Navigational Officers based on AHP Analysis (AHP 분석 기반 항해사 필요 선박조종성능 식별 연구)

  • Kang, Suk-Young;Ahn, Young-Joong;Yu, Yong-Ung;Lee, Yun-Sok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.5
    • /
    • pp.800-808
    • /
    • 2022
  • The International Maritime Organization adopted the interim standards for ship maneuverability in November 1993 for preventing collision of ships at sea and for protecting the marine environment, and based on the accumulated data, in December 2002, the established standards for ship maneuverability were adopted. However, the standards adopted are those at full load, even keel, and at least 90 % of the ship speed at 85 % of the ship's maximum power. Moreover, these standards have limitations in providing information on maneuverability under actual navigational conditions. Therefore, in this study, frequency analysis AHP analysis techniques were studied by consulting navigational officers, captains, and experts, who have significant knowledge on ship maneuverability, utilization of the current standards, and the information necessary for the operation of the actual ship. The results of this study confirmed that the necessary information on maneuverability for the navigational officer operating the vessel is information about the turning circle at a small angle of 5°-10° and z-test information at maneuvering speed, not sea speed. Additionally, in relation to speed control, additional information on deceleration inertia and acceleration inertia is needed than the information on the stopping ability at sea speed and full loaded condition. The derived results are considered to be useful as basic data for preparing guidelines for ship maneuverability necessary for navigational of icers who operate ships.

Mechanical Properties of a High-temperature Superconductor Bearing Rotor in a 10 kWh Class Superconductor Flywheel Energy Storage System (10 kWh급 초전도 베어링 회전자의 기계적 특성 평가)

  • Park, B.J.;Jung, S.Y.;Kim, C.H.;Han, S.C.;Park, B.C.;Han, S.J.;Doo, S.G.;Han, Y.H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • Recently, superconductor flywheel energy storage systems (SFESs) have been developed for application to a regenerative power of train, a power quality improvement, the storage of distributed power sources such as solar and wind power, and a load leveling. As the high temperature superconductor (HTS) bearings offer dynamic stability without the use of active control, accurate analysis of the HTS bearing is very important for application to SFESs. Mechanical property of a HTS bearing is the main index for evaluating the capacity of an HTS bearing and is determined by the interaction between the HTS bulks and the permanent magnet (PM) rotor. HTS bearing rotor consists of PM and iron collector and the proper dimension design of them is very important to determine a supporting characteristics. In this study, we have optimized a rotor magnet array, which depends on the limited bulk size and performed various dimension layouts for thickness of the pole pitch and iron collector. HTS bearing rotor was installed into a single axis universal test machine for a stiffness test. A hydraulic pump was used to control the amplitude and frequency of the rotor vibration. As a result, the stiffness result showed a large difference more than 30 % according to the thickness of permanent magnet and iron collector. This is closely related to the bulk stiffness controlled by flux pining area, which is limited by the total bulk dimension. Finally, the optimized HTS bearing rotor was installed into a flywheel system for a dynamic stability test. We discussed the dynamic properties of the superconductor bearing rotor and these results can be used for the optimal design of HTS bearings of the 10kWh SFESs.

Estimation of Soil Cooling Load in the Root Zone of Greenhouses (온실내 근권부의 지중냉각부하 추정)

  • 남상운
    • Journal of Bio-Environment Control
    • /
    • v.11 no.4
    • /
    • pp.151-156
    • /
    • 2002
  • Root zone cooling, such as soil or nutrient solution cooling, is less expensive than air cooling in the whole greenhouse and is effective in promoting root activity, improving water absorption rate, decreasing plant temperature, and reducing high temperature stress. The heat transfer of a soil cooling system in a plastic greenhouse was analyzed to estimate cooling loads. The thermal conductivity of soil, calculated by measured heat fluxes in the soil, showed the positive correlation with the soil water content. It ranged from 0.83 to 0.96 W.m$^{[-10]}$ .$^{\circ}C$$^{[-10]}$ at 19 to 36% of soil water contents. As the indoor solar radiation increased, the temperature difference between soil surface and indoor air linearly increased. At 300 to 800 W.m$^{-2}$ of indoor solar radiations, the soil surface temperature rose from 3.5 to 7.$0^{\circ}C$ in bare ground and 1.0 to 2.5$^{\circ}C$ under the canopy. Cooling loads in the root zone soil were estimated with solar radiation, soil water content, and temperature difference between air and soil. At 300 to 600 W.m$^{-2}$ of indoor solar radiations and 20 to 40% of soil water contents,46 to 59 W.m$^{-2}$ of soil cooling loads are required to maintain the temperature difference of 1$0^{\circ}C$ between indoor air and root zone soil.

Design of the Power-LED Driver for High Speed Dimming Control (고속 디밍제어를 위한 고출력-LED 드라이버 설계)

  • Lee, Keon;Kang, Woo-Seong;Jung, Tae-Jin;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.128-135
    • /
    • 2013
  • This paper presents a high dimming ratio Power-LED driver IC with high power which is capable of controlling LEDs. In order to accomplish a high dimming ratio LED driver, the preloading inductor current methodology is proposed for the power stage of the proposed method to achieve the fast transient response time during the Power-LED load switching. The information containing the current flowing on the LEDs can be utilized to predict the amount of the current on the inductor. The minimum LED current rising time of existing high dimming ratio Power-LED driver is limited by $3{\mu}s$, however that of the proposed high dimming ratio Power-LED driver is reduced about 1/10. The LED driver is implemented with 0.35um 60V BCDMOS 2-poly 4-metal process. The measurement results show that the proposed LED driver system features the minimum rising time as small as 240ns at the dimming frequency of 1KHz with a 12V of input voltage, nine white LEDs and 353mA of LED current. The LED rising time and power conversion efficiency of the chip are measured to be 240ns and 93.72%, respectively.

Development of Robotic System based on RFID Scanning for Efficient Inventory Management of Thick Plates (효율적인 후판 재고관리를 위한 RFID 스캐닝 로봇 시스템 개발)

  • Lee, Kwang-Hyoung;Min, So-Yeon;Lee, Jong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.1-8
    • /
    • 2016
  • Automation of inventory management in a steel plate factory was a difficult problem unresolved for a long time. And now, it is also necessary to work diligently in the steel industry on efficient inventory management of thick plates. So far, the environmental characteristics of stacked thick plates means it is not easy to apply advanced technology for their automatic identification. In this paper, we propose a thick-plate robotic scanning system based on radio-frequency identification (RFID) that can provide quick and accurate inventory management by acquiring plate information after the scanning automatically recognizes the RFID tags under difficult load conditions. This system is equipped with a crane to move the plates in a pulled-up operation. It is equipped with a plate-only linear dipole antenna only for scanning the position of the plate tag. Only the linear dipole antenna, while moving the x-axis and y-axis information, automatically identifies the tag information attached to the plate. The tag information acquired by the system is used for stockpiling and is managed by steel plate inventory control software. The effectiveness of the proposed system is verified through field performance evaluation. As a result, the recognition rate of the plate tags is 99.9% at a maximum distance of 320 cm. The developed thick-plate antenna showed excellent performance compared to an existing commercial antenna.