• Title/Summary/Keyword: Load Fluctuation

Search Result 271, Processing Time 0.028 seconds

A study on the Algorithm for the Economic Dispatch of Thermal Units Considering Dynamic Characteristics of Load (부하의 동특성을 고려한 화력발전기의 경제부하배분 앨고리즘에 관한 연구)

  • Song, Kil-Yeong;Park, Kyeng-Soo;Choi, Jae-Suck;Park, Hyun-Sin
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.92-94
    • /
    • 1988
  • One of the recurring problems facing energy control center dispatchers each day is how to operate the system during the periods of high load pick up and fluctuation. This method reduces the problem to a forward - revised by backward - sequence of dispatch problem, with the generator Limits being carefully adjusted between each time interval in the total intervals to be optimized. It is applied to system of 31 units. It is observed that the method presented here achieves that generation fellows the load changes without any mismatch.

  • PDF

A Flyback DC-DC Converter Employing a Synchronous Rectifier Driven by a New Voltage/Current Mixed Method (전압 전류 혼합구동방식을 적용한 동기정류기형 플라이백 DC-DC 컨버터)

  • Lee, Darl-Woo;Ahn, Tae-Young
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.9
    • /
    • pp.472-477
    • /
    • 2006
  • This paper presents a new voltage/current mixed method for driving synchronous rectifiers (SR) adapted to the flyback topology. The synchronous rectifier driven by the proposed voltage/current mixed method can operate at a wide load range with high efficiency. The gate voltage of MOSFET in the synchronous rectifier can be easily controlled by changing the ratio of resistors, irrespective of a line and load fluctuation. A 200W (12V/17A) prototype converter was built and an efficiency of 93% was measured at 10A load current.

C-link Ripple Voltage Compensation Algorithm for Integrated ESS and UPS System with PV Generation (태양광 발전을 갖는 통합 ESS 및 UPS 시스템의 직류 링크 맥동전압 보상 알고리즘)

  • Kim, Min-Gi;Choi, Bong-Yeon;Kang, Jin-Wook;Kim, Jun-Gu;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.443-444
    • /
    • 2014
  • Using the ESS(Energy Storage System) as a UPS(Uninterruptible Power Supply) is being studied recently. When the system is operating at UPS mode in integrated ESS and UPS system, the grid supplying power is disconnected and power from PV generation and battery are supplying to load. Operating in UPS mode, when PV generation power is diminished by partial or total clouded situation, DC-link voltage fluctuates. The fluctuation of DC-link voltage influences the load and system as sensitive loads may malfunction. This paper suggests the DC-link ripple voltage compensation algorithm in bi-directional converter. The algorithm stabilize the DC-link and load voltage.

  • PDF

A high efficiency 200W Adaptor with new voltage-current driven synchronous rectfier (전압전류 혼합 구동방식의 동기정류기를 이용한 200W급 고효율 AC Adaptor에 관한 연구)

  • Won, Ki-Sik;Lee, Darl-Woo;Ahn, Tae-Young;Kim, Sung-Cheol;Jang, Chan-Gyu;Kim, Young-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.182-185
    • /
    • 2005
  • This paper presents a new voltage current driven method for the synchronous rectifier (SR) in a flyback topology. The proposed synchronous rectfier of voltage-current driven can operate at wide load range with high efficiency. The gate voltage of FET in the synchronous rectifier is easily controlled by resistor ratio. regardless of line and load fluctuation. The 200W (l2V/17A) prototype is built and achiveved efficiency as high as 90% at 4A, 93.2% at 7A and full load.

  • PDF

Operational Mode Analysis of Cooler Driver Electronics in Satellite and System Safety Margin

  • Kim, Kyudong
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.79-84
    • /
    • 2020
  • Cooler driver electronics (CDE) for maintaining low temperature of the satellite payload IR sensor consists of a compressor that has a pulsation current load condition when it is operated. This pulsation current produces large voltage fluctuation, which affects both load and regulated bus stability. Thus, CDE power conditioning system consists of a primary bus, infrared power distribution unit for battery charging and protection, reverse current protection diode, and battery, which is used as a buffer. In this study, the operational mode analysis is performed by each part with equivalent impedance modeling verified through system level simulation. From this mode analysis, the safety margin for state of charge and open circuit voltage of the battery is determined for satisfying the minimum operational voltage of the CDE load.

Numerical Investigation of Pressure Fluctuation Reducing in Draft Tube of Francis Turbines

  • Li, WF;Feng, JJ;Wu, H;Lu, JL;Liao, WL;Luo, XQ
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.202-208
    • /
    • 2015
  • For a prototype turbine operating under part load conditions, the turbine output is fluctuating strongly, leading to the power station incapable of connecting to the grid. The field test of the prototype turbine shows that the main reason is the resonance between the draft tube vortex frequency and the generator natural vibration frequency. In order to reduce the fluctuation of power output, different measures including the air admission, water admission and adding flow deflectors in the draft tube are put forward. CFD method is adopted to simulate the three-dimensional unsteady flow in the Francis turbine, to calculate pressure fluctuations in draft tube under three schemes and to compare with the field test result of the prototype turbine. Calculation results show that all the three measures can reduce the pressure pulsation amplitude in the draft tube. The method of water supply and adding flow deflector both can effectively change the frequency and avoid resonance, thus solving the output fluctuation problem. However, the method of air admission could not change the pressure fluctuation frequency.

Highly AC Voltage Fluctuation-Resistant LED Driver with Sinusoid-Like Reference

  • Ning, Ning;Tong, Zhenxiao;Yu, Dejun;Wu, Shuangyi;Chen, Wenbin;Feng, Chunyi
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.257-264
    • /
    • 2014
  • A novel converter-free AC LED driver that is highly resistant to the fluctuation of AC voltage is proposed in this study. By removing large passive components, such as the bulky capacitor and the large-value inductor, the integration of the driver circuit is enhanced while the driving current remains stable. The proposed circuit provides LED lamps with a driving current that can follow the sinusoid waveform to obtain a very high power factor (PF) and low total harmonic distortion (THD). The LED input current produced by this driving current is insensitive to fluctuations in the AC voltage. Users will thus not feel that LED lamps are flashing during the fluctuation. Experiment results indicate that the proposed system can obtain PF of 0.999 and THD as low as 3.3% for a five-string 6 W LED load under 220 V at 50 Hz.

Effect of Nitrogen-Load Condition on Hydrogen Production and Bacterial Community in Continuous Anaerobic Hydrogen Fermentation Process

  • Kawagoshi, Yasunori;Nakao, Masaharu;Hino, Naoe;Iwasa, Tomonori;Furukawa, Kenji
    • Journal of Wetlands Research
    • /
    • v.9 no.1
    • /
    • pp.123-131
    • /
    • 2007
  • Effect of nitrogen-load condition on hydrogen ($H_2$) production and bacterial community in a continuous anaerobic hydrogen fermentation were investigated. The slight $H_2$ production on extremely low nitrogen-load condition (C/N ratio: 180) at the start-up period. The highest $H_2$ production was obtained when the C/N ratio was 36, the $H_2$ production yield ($mol-H_2/mol-glucose$) reached to 1.7, and it was indicated that Clostridium pasteurianum mainly contributed to the $H_2$ production. The $H_2$ production was decreased on both the lower (C/N: 72) and higher (C/N: 18) nitrogen-load conditions. The excess nitrogen-load was not always suitable for the hydrogen production. The fluctuation of $H_2$ production seemed to be caused by a change in the bacterial community according to the nitrogen-load condition, while a recovery of $H_2$ productivity was possible by a control of nitrogen-load condition through the bacterial community change. When the nitrogen-load condition was not suitable for hydrogen production, the lactic acid concentration was increased and also lactic acid bacteria were definitely detected, which suggested that the competition between hydrogen fermentator and lactic acid producer was occurred. These results demonstrated that the nitrogen-load condition affect on the $H_2$ productivity through the change of bacterial community in anaerobic hydrogen fermentation.

  • PDF

Immune Based 2-DOF PID Controller Design for Complex Process Control

  • Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.70.2-70
    • /
    • 2002
  • In the thermal power plant, it is difficult to maintain strict control of the steam temperature in order to avoid thermal stress, because of variation of the heating value according to the fuel source, the time delay of changes in main steam temperature versus changes in fuel flow rate, difficulty of control on the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, fluctuation of inner fluid water and steam flow rates widely during load-following operation. Up to the present time, the PID controller has been used to operate this system...

  • PDF

A New Design Analysis of Flywheel (플라이휠의 새로운 설계 해석)

  • 김재호;신영재
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.1063-1066
    • /
    • 1991
  • 본 연구에서는 기계 기구의 각속도 변동을 줄이는데 사용되는 플라이휠을 운동에너지의 법칙을 이용하여 해석하고, 주어진 허용 각속도 변동률을 정확히 만족하 는 플라이휠의 크기를 결정하는 새로운 방법을 제시하였다. 또한 수치 해석을 통하 여 본 해석방법에 의해 설계된 플라이휠과 종래 방법에 의한 플라이휠의 성능을 비교 하였다.