• Title/Summary/Keyword: Load Carrying Performance

검색결과 310건 처리시간 0.035초

고인성섬유 복합모르타르 PC판넬을 활용한 철근콘크리트 골조의 리모델링을 위한 보강시스템 개발 (Development of Rerofitting System for the Remodeling of Reinforced Concrete Frame Using High Ductile Fiber Composite Mortar PC Panel)

  • 하기주;신종학;김윤용;홍건호;양승혁;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.66-69
    • /
    • 2006
  • Three reinforced concrete rigid frames and infilled rigid frames with new retrofitting system were tested under both vertical and cyclic loadings, Experimental programs were carried out to evaluate and improve the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. All the specimens were modeled in one-third scale size. For specimens(RFHPC, RFAR) designed by the improving of seismic performance of the rigid frame using the high ductile fiber composite PC panel and ALC panel system, load-carrying capacities were increased $1.45{\sim}2.28$ times, and hysteretic behavior was very stable during the final tests in comparison with the standard specimen(SRF).

  • PDF

Repair Performance of Engineered Cementitious Composites(ECC) Treated with Wet-Mix Spraying Process

  • Kim, Yun-Yong
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권3E호
    • /
    • pp.207-211
    • /
    • 2006
  • This paper presents an experimental study on the repair performance of sprayed engineered cementitious composites(ECC) serving as a repair material. Sprayable ECC, which exhibit tensile strain-hardening behavior in the hardened state and maintain sprayable properties in the fresh state, have been developed by using a parallel control of micromechanical design and rheological process design. The effectiveness of sprayable ECC in providing durable repaired structures was assessed by spraying the ECC and testing them for the assessment. The experimental results revealed that, when sprayed ECC were used as a repair material, both load carrying capacity and ductility represented by the deformation capacity at peak load of the repaired flexural beams were obviously increased compared to those of commercial prepackaged mortar(PM) repaired beams. The significant enhancement in the energy absorption capacity and tight crack width control of the ECC repair system treated with wet-mix spraying process suggests that sprayed ECC can be effective in extending the service life of rehabilitated infrastructures.

21T 초전도자석을 위한 전류도입선 예비설계 (Preliminary Design of Current Lead for 21T Superconducting Magnet)

  • 최연석;김동락;양형석;이병섭
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권3호
    • /
    • pp.43-46
    • /
    • 2008
  • Design of current lead for 21T superconducting magnets is presented. The current lead is composed of a normal metal element, conducting the current from room temperature to intermediate temperature, and an HTS element, conducting the current down to liquid helium temperature. The metal element is disengaged from the HTS element without breaking vacuum after excitation. The optimization of the lead is performed to minimize the thermal heat load when carrying operational current with some margin. In order to confirm the feasibility of our new design, the intermediate joint between a normal metal and HTS element is fabricated and the reliability is tested during engage and disengage performance. The effects of vacuum level and performance cycle on the electrical contact resistance are also investigated.

Seismic performance of precast joint in assembled monolithic station: effect of assembled seam shape and position

  • Liu, Hongtao;Du, Xiuli
    • Earthquakes and Structures
    • /
    • 제17권6호
    • /
    • pp.611-621
    • /
    • 2019
  • Precast concrete structure has many advantages, but the assembled seam will affect potentially the overall seismic performance of structure. Based on the sidewall joint located in the bottom of assembled monolithic subway station, the main objectives of this study are, on one hand to present an experimental campaign on the seismic behavior of precast sidewall joint (PWJ) and cast-in-place sidewall joint (CWJ) subjected to low-cycle repeated loading, and on the other hand to explore the effect of shape and position of assembled seam on load carrying capacity and crack width of precast sidewall joint. Two full-scale specimens were designed and tested. The important index of failure pattern, loading carrying capacity, deformation performance and crack width were evaluated and compared. Based on the test results, a series of different height and variably-shape of assembled seam of precast sidewall joint were considered. The test and numerical investigations indicate that, (1) the carrying capacity and deformation capacity of precast sidewall and cast-in-place sidewall were very similar, but the crack failure pattern, bending deformation and shearing deformation in the plastic hinge zone were different obviously; (2) the influence of the assembled seam should be considered when precast underground structures located in the aquifer water-bearing stratum; (3) the optimal assembled seam shape and position can be suggested for the design of precast underground concrete structures according to the analysis results.

이중범프포일 공기베어링의 성능해석 (Performance Analysis of Double-Bumped Air Foil Bearings)

  • 김영철;이동현;김경웅
    • Tribology and Lubricants
    • /
    • 제23권3호
    • /
    • pp.123-129
    • /
    • 2007
  • This paper presents a theoretical model for the analysis of double-bumped AFBs. The stiffness and damping coefficients of the double bump vary depending on the external load and its friction coefficient. In the case of a lightly loaded condition where only the upper bump contributes to deformation, the double bump is in the single active region. In the case of a heavily loaded condition where both the upper and lower bumps contribute to deformation, the double bump is in the double active region. So the double bump can be either in the single or double active region depending on vertical deflection. The equivalent stiffness and damping coefficients of the bump system are derived from the vertical and horizontal deflection of the bump, including the friction effect. A static and dynamic performance analysis is carried out by using the finite difference method and the perturbation technique. The results of the performance analysis for a double-bumped AFB are compared with those obtained for a single-bumped AFB. This paper successfully proves that a double bumped AFB has higher load capacity, stiffness, and damping than a single-bumped AFB in a heavily loaded condition.

Dent 손상을 갖는 원통부재의 최종강도에 관한 연구(제2보) -굽힘 하중을 받는 경우- (Ultimate Strength of Dented Tubular Members(2nd report) -under Bending Loads-)

  • 노인식;전태병;조병삼
    • 대한조선학회논문집
    • /
    • 제41권6호
    • /
    • pp.56-64
    • /
    • 2004
  • Several types of steel structures which are employed in offshore petroleum activities are constructed with tubular members. These structures are usually subjected to various types of loads such as normal functional loads and environmental loads. Furthermore, accidental loads may also act on the leg or bracing members due to supply boat collisions and objects droppings from platform decks. The extent of damage caused by these loads ranges from total collapse of the structure to small damage which may not have serious consequence at the time of accident. To make optimal design decisions regarding structural safety and economical efficiency, it is very important to be able to assess the influence of damages on the performance of damaged structural members. In the End report, a series of calculations is performed to study the effects of different parameters on the load carrying capacity of such damaged members under pure bending. And the results of analysis are compared with experiment results.

유한요소해석을 이용한 디스크 커플링의 토크전달 능력에 대한 연구 (A Study on the Torque Transmitting Capability of a Disk Coupling by Finite Element Analysis)

  • 서원상;김성묵;김종봉
    • 한국정밀공학회지
    • /
    • 제30권11호
    • /
    • pp.1171-1177
    • /
    • 2013
  • In this study, the torque transmitting capability of a flexible disk coupling was investigated. Flexible disc coupling is used to transmit power between two axes, and there exist mis-alignments such as angle of deviation and end play between two shafts. A disk is an important part in the flexible disk coupling because the disk has to transmit power between two mis-aligned shafts. To investigate the effect of mis-alignment on load carrying capacity, finite element analyses were carried out. Analyses were carried out for two types of disk; i.e., circular and square disks. The rotational and bending stiffness of disk plates was predicted to investigate the effect of mis-alignment on stress. As a result, it was shown that the mis-alignment can cause severe decrease in load-carrying capacity. And, the square disk showed better performance than the circular disk.

나노입자를 적용한 냉장고 압축기용 오일의 윤활특성 평가 (Performance Evaluation of Nano-Lubricants at Refrigeration Oil)

  • 이광호;황유진;권래언;이재근;김석로;방선욱
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.184-188
    • /
    • 2008
  • It has been recognized that friction coefficient decreased with decreasing viscosity of oil in lubrication. In general, the more viscosity decreases, the more wear rate increases due to decrease load carrying capacity. It has been proposed that nano particles in oil decrease friction coefficient and wear rate. The purpose of this study is to apply oil of lower viscosity that mix with nano particles at the compressor used in a refrigerator to decrease friction coefficient keeping Load carrying capacity. Mineral oil of 8 cSt were used and mixed with nano particle. Friction coefficient was evaluated by a disk-on-disk tester. As a result, friction coefficient of nano oil decreased by 90% in comparison with raw oil. These results lead us to the conclusion that nano oil is new plan to raise efficiency of the compressor.

  • PDF

Nonlinear analysis of cable-stayed spatial latticed structures

  • Zhou, Dai;Liu, Hongyu;Jin, Bo
    • Structural Engineering and Mechanics
    • /
    • 제15권4호
    • /
    • pp.415-436
    • /
    • 2003
  • The combination of spatial latticed structures (hereafter SLS) and flexible cables, the cable-stayed spatial latticed structures (hereafter CSLS) can cross longer span. According to variation principle, a novel geometric nonlinear formulation for 3-D bar elements considering large displacement and infinitesimal rotation increments with second-order precision is developed. The cable nonlinearity is investigated and it is taken that the secant modulus method can be considered as an exact method for a cable member. The tower column with which the cables link is regarded as a special kind of beam element, and, a new simplified stiffness formulation is presented. The computational strategies for the nonlinear dynamic response of structures are given, and the ultimate load carrying capacities and seismic responses are analyzed numerically. It is noted that, compared with corresponding spatial latticed shells, the cable-stayed spatial latticed shells have more strength and more stiffness, and that the verical seismic responses of both CSLS and CLS are remarkably greater than the horizontal ones. In addition, the computation shows that the stiffness of tower column influences the performance of CSLS to a certain extent and the improvement of structural strength and stiffness of CSLS is relevant not only to cables but also to tower columns.

Experimental study on the hybrid shear connection using headed studs and steel plates

  • Baek, Jang-Woon;Yang, Hyeon-Keun;Park, Hong-Gun;Eom, Tae-Sung;Hwang, Hyeon-Jong
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.649-662
    • /
    • 2020
  • Although several types of rigid shear connectors have been developed particularly to increase load-carrying capacity, application is limited due to the complicated details of such connection. In this study, push-out tests were performed for specimens with hybrid shear connectors using headed studs and shear plates to identify the effects of each parameter on the structural performance of such shear connection. The test parameters included steel ratios of headed stud to shear plate, connection length, and embedded depth of shear plates. The peak strength and residual strength were estimated using various shear transfer mechanisms such as stud shear, concrete bearing, and shear friction. The hybrid shear connectors using shear plates and headed studs showed large load-carrying capacity and deformation capacity. The peak strength was predicted by the concrete bearing strength of the shear plates. The residual strength was sufficiently predicted by the stud shear strength of headed studs or by shear friction strength of dowel reinforcing bars. Further, the finite element analysis was performed to verify the shear transfer mechanism of the connection with hybrid shear connector.