• Title/Summary/Keyword: Load & Outlet Flow Rate

Search Result 33, Processing Time 0.021 seconds

A Flow Visualization of ER Fluids in 3Port Rectangular Tube (3 포트 사각 튜브내에서 ER유체의 유동 가시화)

  • Jang Sung-Cheol;Yum Man-Oh;Jang Mun-Jey
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.30-37
    • /
    • 2006
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. ER fluids are made with silicone oil and 3 weight fraction starch having hydrous particles. The flow visualization of ER fluids flow is obtained by CCD camera with changing the strength of electric field to ER fluids flow. As the strength of the electric field increases, more clusters in flow are made and these clusters are though to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system.

Performance Test of 3 Port ERF Valve for Controlling Flow Rate-Direction (3 포트 ERF 밸브의 유량-방향 제어 성능 실험 -유압시스템 및 자동화 융합연구-)

  • Jang, S.C.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.92-97
    • /
    • 2012
  • In this study, ER fluids were working fluid and yield shear stress of attained dispersive ER fluids made by analyzed to adapt effectively at the practical equipment like three port ER valve. In addition, movement of ER particle was observed by using a microscope the same as the strength of electric field with Bingham characteristic. Basis material was presented to develop 3 port ER-Valve by quantitatively comparing and analyzing entrance, load and outlet flow's differences of 3 port rectangular tubes. This study, after designing and producing the 3port ER-Valve, considered the characteristic of pressure drop, outlet and load flow rate by changing the strength of electric field on ER fluids flowing between electrodes.

A Study on the Control Characteristics of FHA by Using PLC (PLC를 이용한 ER밸브-FHA의 제어특성에 관한 연구)

  • Jang, Sung-Cheol;Hong, Soon-Nam
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.331-336
    • /
    • 2013
  • The purpose of this study is to visualize the characteristics of ER fluids as preceding step of developing 3 port ER valves. As the strength of the electric field increases, more clusters in flow are made and these clusters are thought to be the reasons of the load flow rate being increased and the outlet flow rate being decreased. The ER Valves and load and outlet flow rate check method are considered to be applied to the fluid power control system. Using the manufactured pressure control valve, a one-link manipulator with FHA in robot system is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller(PLC).

Control of Advanced Reactor-coupled Heat Exchanger System: Incorporation of Reactor Dynamics in System Response to Load Disturbances

  • Skavdahl, Isaac;Utgikar, Vivek;Christensen, Richard;Chen, Minghui;Sun, Xiaodong;Sabharwall, Piyush
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1349-1359
    • /
    • 2016
  • Alternative control schemes for an Advanced High Temperature Reactor system consisting of a reactor, an intermediate heat exchanger, and a secondary heat exchanger (SHX) are presented in this paper. One scheme is designed to control the cold outlet temperature of the SHX ($T_{co}$) and the hot outlet temperature of the intermediate heat exchanger ($T_{ho2}$) by manipulating the hot-side flow rates of the heat exchangers ($F_h/F_{h2}$) responding to the flow rate and temperature disturbances. The flow rate disturbances typically require a larger manipulation of the flow rates than temperature disturbances. An alternate strategy examines the control of the cold outlet temperature of the SHX ($T_{co}$) only, since this temperature provides the driving force for energy production in the power conversion unit or the process application. The control can be achieved by three options: (1) flow rate manipulation; (2) reactor power manipulation; or (3) a combination of the two. The first option has a quicker response but requires a large flow rate change. The second option is the slowest but does not involve any change in the flow rates of streams. The third option appears preferable as it has an intermediate response time and requires only a minimal flow rate change.

Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis (이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계)

  • Dong-Soo, Choi;Yong-Hoon, Kim;Jin-SE, Kim;Chun-Wan, Park;Hyun-Mo, Jung;Ghi-Seok, Kim;Jong-Min, Park
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.3
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

Heat Load Characteristics of Sea Water Cooling Apparatus on Inshore Fishing Boat (연근해 어선용 해수냉각장치의 열부하특성)

  • 한인근;문춘근;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1317-1323
    • /
    • 2001
  • The circumstance is giving the blow against fishermen with the incoming-decreasing and the difficulty of crew's supply & demand and management. In addition, the depression of the external situation like the departure of WTO system and the plan of EEZ proclaim is forcing fishery into improving their fishing condition. By this international and domestic circumstance, development of the sea water cooling apparatus for fish hold storage is demanded sincerely. First of all, we Investigated load characteristics which based on development of sea water cooling system and optimum fish hold storage. The experimental results is as follows. In creasing the speed of compressor and mass blew rate of refrigerant, the temperature of NaCl solution is low. And the load characteristics experiment on fish hold storage outlet is as fellows. As time goes by, increasing the mass flow rate of NaCl solution, temperature difference between inlet and outlet is small in a model of fish hold storage. These results provide many useful informations applicable to an actual design of sea water cooling system and optimum fish hold storage.

  • PDF

pollutant Load Characteristics of a Agricultural Watershed in Juam Lake (주암호 농업유액 오염부하 특성)

  • Yoon, Kwang-Sik;Choi, Soo-Myung;Han, Kuk-Heon;Cho, Jae-Young
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.433-436
    • /
    • 2002
  • A subwatershed within Juam Lake was monitored to identify hydrologic and water quality characteristics. Rainfall record was collected and flow rate measurement and water quality sampling were conducted periodically at the watershed outlet. Hydrologic response and pollutant load characteristics were analyzed based on observed data.

  • PDF

A High Power Micropump Using Active Check Valves Driven by Piezoelectric Actuators (압전구동 능동형 체크밸브를 이용한 고출력 마이크로펌프)

  • Kang, Jung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.4
    • /
    • pp.39-47
    • /
    • 2005
  • In this paper, a novel high power micropump using active check valves in place of conventional passive check valves employed at the inlet and outlet ports is presented. It actively controls open/close motion of check valves using piezoelectric actuator for expansion/contraction of pump chamber. A prototype micropump having an effective size of $17mm{\times}8mm{\times}11mm$ is fabricated. Frequency-dependent flow rate characteristics, bi-directional flow characteristics and load characteristics are experimentally investigated using a timing control method for valve closing motion. From the obtained experimental results, it is ascertained that optimal values of the phase shift compared to the voltage to drive pump chamber are $15^{\circ}$ for inlet check valve and $195^{\circ}$ for outlet. Based on the obtained results, a sheet-type active shuttle valve that has a unified valve-body for inlet and outlet check valves is proposed. A micropump with an effective size of $10mm{\times}10mm{\times}10mm$ is fabricated and the basic characteristics are experimentally investigated.

  • PDF

Analysis of Connecting Rod Bearings Using Mass-Conserving Boundary Condition (유량 보존 경계 조건을 적용한 커넥팅 로드 베어링의 성능 해석)

  • 김병직;김경웅
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.39-45
    • /
    • 1998
  • Reynolds equation, which describes behavior of fluid film in journal bearings, basically satisfies mass conservation. But, boundary conditions usually used with this equation, e.g. half Sommerfeld or Reynolds boundary conditions, cannot fulfill this natural law of conservation. In the case of connecting rod bearing, where applied load is dynamic and its magnitude is relatively large, such unrealistic boundary conditions have serious influence on calculation results, especially on lubricant flow rate or power disspation which are important parameters in thermal analysis. In this paper, mass-conserving boundary condition was applied in the finite element analysis of connecting rod bearings. Lubricant flow rate and power dissipation rate were calculated together with journal center locus, minimum film thickness and maxmium film pressure. These computation results were compared with those of the case of Reynolds boundary condition. Balance between inlet and outlet flow rate was well achieved in the case of mass-conserving boundary condition.

Shape Design of the 3-Way Valve used in Marine Diesel Engines (LDCL JWCS) by CFD Analysis (유동해석을 통한 선박용 디젤엔진(LDCL JWCS)의 3-Way Valve 형상 설계)

  • Hwang, Gi Ung;Kwak, Hyo Seo;Kim, Jae Yeol;Eom, Tae Jin;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.11
    • /
    • pp.1077-1084
    • /
    • 2017
  • Camshaft engines designed for constant engine loads have been applied to existing marine diesel engines. However, due to environmental regulations, electro-hydraulic servo mechanisms, which have a loaddependent cylinder liner jacket water cooling system (LDCL-JWCS), have been recently developed to individually control the temperature of the cylinders depending on the engine load. In this system, the 3-way valve, which prevents low temperature corrosion by reducing the temperature difference between the upper and lower parts of the cylinder, has been employed, but the outlet mass flow of the existing valve is low. In this study, the design of the internal shape of the 3-way valve was performed by analyzing the effects of the design parameters of the valve shape on the performance (i.e., the outlet mass flow rate and temperature). The proposed model was verified by comparing its performance to that of existing marine diesel engine valves.