• Title/Summary/Keyword: Living Room

Search Result 864, Processing Time 0.024 seconds

A Study on the Tile Mural Decoration Design Using Colored Glass Plaster Technique (색유리 플래스터 기법을 이용한 타일 벽장식 방안 연구)

  • Kim, Seung-Man
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.12
    • /
    • pp.460-470
    • /
    • 2020
  • In modern life, interior decoration has been transformed into a psychological synergistic effect of space, greatly affecting human sensibility. The main point of view in this paper is to study the discovery of new decorative effects and the possibility of products that can replace imported tiles, which account for more than 60% of the walls of indoor spaces closely related to daily life. The solution is to create point tiles using color glass plaster techniques developed in 2018 and to explore the possibility of decorating art walls to meet consumers' purchasing needs using simulations. The four patterns applied to the a paintbrush, resist printing, cutting technique, and inlaid patterns, and the traditional color development effect of the medium color suited to our sensibilities was studied. In addition, through simulation, art walls and acrylic using color glass styles were also used in the kitchen, living room and empty space of the bathroom. Based on this research, ceramic point tiles with a new perspective will be explored and the interior using walls will be activated.

A Study on Fire Dynamics Simulation on the Arrangement of Aero System in the Residential (주거공간 에어로 시스템 배치에 관한 화재시뮬레이션 연구)

  • Choi, Doo Chan;Ko, Min Hyeok;Lee, Doo Hee;Park, Kye Won;Choi, Jeong Min;Lee, Yong Kwon;Kim, Gil Nam;Sun, Kyoung Soo
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.890-896
    • /
    • 2021
  • Purpose: The called Aero System is important to find the well detected place in the livingroom or bedroom so, it needs to the confirmation through the Fire Dynamics Simulation Method: A fire simulation of a residential space of 59 m2 was performed, and in order to find the point where the fire environment was exposed quickly, measuring points were installed at 0.6 m and 1.5 m in height for each bedroom and living room, and the point where the fire was quickly detected was confirmed. Result: It was confirmed that the temperature and carbon monoxide sensor set at a point of 1.5 m was quickly detected at the reference value. Conclusion: The Fire detection would be relatively quick if the product in which the fire extinguishing module and the AQI module were separated was installed on the wall.

International Laws for the Prevention of IUU Fishing and Improvement Plans for Related Law Systems in Korea (IUU 어업 방지를 위한 국제적 규범과 우리나라 관련 법제의 개선방안)

  • Yang, Gi-Ju;Kim, In-Guek
    • The Journal of Fisheries Business Administration
    • /
    • v.53 no.3
    • /
    • pp.43-64
    • /
    • 2022
  • Efforts to prevent IUU fishing began in 1996 as the IUU Antarctic Marine Living Resources Conservation Committee reported the multilateral efforts of the international community and related international organizations to prevent IUU fishing. Korea has recently been pointed out by the international community as to many problems regarding its will to eradicate IUU fishing. It is true that Korea has ever been designated as an 'IUU participating country' or a 'non-cooperative third country' by the international community and that there have been considerable difficulties in exporting seafood and using ports along with the deterioration of the national image. In 2020, with the efforts of related organizations and fisheries companies, Korea is now free from being known as a that Korea has recovered some degrees of trust from the international community through strengthening legal sanctions against IUU fishing and thorough implementation of follow-up measures is now free from non-cooperating country it cannot be said that the basic problems have been completely resolved just because it has emerged as a disgraceful country, and the current state of IUU fishing of Korea leaves a room for designation as a 'non-cooperative third country' again at any time in the future. Accordingly, there is an urgent need to examine the problems of the IUU fishing-related legal system in Korea and to come up with an improvement plan. Therefore, this paper reviews international norms for IUU fishing regulation (PSMA etc.) and domestic laws with the Distant Water Fisheries Development Act and Propose the improvement methods for related legal systems in Korea.

Fabrication of Pt/Carbon Nanotube Composite Based Electrochemical Hydrogen Sulfide Gas Sensor using 3D Printing (3D 프린팅을 이용한 Pt/Carbon Nanotube composite 기반 전기화학식 황화수소 가스 센서 제작)

  • Yuntae Ha;JinBeom Kwon;Suji Choi;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.290-294
    • /
    • 2023
  • Among various types of harmful gases, hydrogen sulfide is a strong toxic gas that is mainly generated during spillage and wastewater treatment at industrial sites. Hydrogen sulfide can irritate the conjunctiva even at low concentrations of less than 10 ppm, cause coughing, paralysis of smell and respiratory failure at a concentration of 100 ppm, and coma and permanent brain loss at concentrations above 1000 ppm. Therefore, rapid detection of hydrogen sulfide among harmful gases is extremely important for our safety, health, and comfortable living environment. Most hydrogen sulfide gas sensors that have been reported are electrical resistive metal oxide-based semiconductor gas sensors that are easy to manufacture and mass-produce and have the advantage of high sensitivity; however, they have low gas selectivity. In contrast, the electrochemical sensor measures the concentration of hydrogen sulfide using an electrochemical reaction between hydrogen sulfide, an electrode, and an electrolyte. Electrochemical sensors have various advantages, including sensitivity, selectivity, fast response time, and the ability to measure room temperature. However, most electrochemical hydrogen sulfide gas sensors depend on imports. Although domestic technologies and products exist, more research is required on their long-term stability and reliability. Therefore, this study includes the processes from electrode material synthesis to sensor fabrication and characteristic evaluation, and introduces the sensor structure design and material selection to improve the sensitivity and selectivity of the sensor. A sensor case was fabricated using a 3D printer, and an Ag reference electrode, and a Pt counter electrode were deposited and applied to a Polytetrafluoroethylene (PTFE) filter using PVD. The working electrode was also deposited on a PTFE filter using vacuum filtration, and an electrochemical hydrogen sulfide gas sensor capable of measuring concentrations as low as 0.6 ppm was developed.

Current Situation and Characteristics of Owner Shop Houses in the Historic Area - Focused on Seongan-dong and Jungang-dong, Cheongju, Korea - (역사적 도심 내 자가(自家) 병용주택의 현황 및 유형별 특성 - 청주시 성안동과 중앙동을 대상으로 -)

  • Yoo, Seul Gi;Jung, Jin Ju;Kim, Tai Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.2
    • /
    • pp.35-40
    • /
    • 2024
  • This study examines the classification and typical characteristics of 148 owner shop houses existing in the historical city center of Cheongju. First, they can be classified into single-story, middle-story, and divided types according to the distribution of residential and commercial functions. The single-story(36) has 'ㅡ', 'ㄱ', and 'narrow and deep'-shaped arrangement, with stores on the front and houses on the rear. The middle-story second floor(89) is divided into a first-story store and a second-story house, and the third floor(23) has different functions for each floor, but more than half of them have houses on the second and third floors. Among the total, there are also 16 cases in which the division type is taken with different construction times and structures. Second, in the position of the stairs connected to the upper floor among the middle-floor types(112), the outer stair type(52) to separate from the living space while making the most of the stores on the first floor accounts for 47%, but the biggest feature is that the inner staircase type(34) with privacy reaches 30%. The rear stair room type(26) entering through alleyways or private yards is also 23%. Third, the front pillar spacing varies from 1bay to 4bay in appearance, but the 2bay type on the 2nd floor and the 1bay type on the 3rd floor occupy the largest proportion. This exterior type is a characteristic of a owner shop house that can measure the range of personal ownership. Despite the conflicting functions of stores and houses, 35~40% of the cases are in which the opening positions of the upper and lower floors are unified.

The Research on the Life-safety Implementation using the Natural Light LED Lamp in the Disaster Prevention and Safety Management (방재안전 자연광 LED 조명을 이용한 생활안전 개선에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;So, Yooseb;Choi, Byungshik;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.53-62
    • /
    • 2016
  • This paper is shown the new method using LED Light, which the light environment is upgraded the natural LED light in the area of Disaster Prevention and Safety Management (PDSD), which the events of deaths is reduced on the Suicide, the Infectious diseases, the safety accidents, the Traffic Accident, the crime, the fire, the Nature Disaster, and which the health and the environment and the safety is implemented using the value of the color LED Light. Research findings include,during 3 weeks in the November 2016, in the ten residents (average living 28.7 years, age 67.5 years) with depressive symptoms in the northern part of Seoul, according to the request of the user, the PDSD natural light LED lighting was installed in the home bedroom or the living room, expectations for the ability to restore physical and mental stability were high (88%), in the same way, after 1 week and 3 weeks, the physical and mental changes were compared and the results,84% in the first week and 90% in the third week and thereafter, the effect of relieving depression was high. We conclude that patients with depression have a good sleep, an uneasy feeling, a sense of security, a good night's sleep, and a good feeling. The PDSD LED Light is expected to contribute in the various areas, which reduced the suicides, which give increased immunity from infectious diseases, which give a crash to reduce accidents caused by negligence, which improve the safe operation of heavy vehicles in which a traffics accident incidence installed on the highest point, which improve the safety function on the 'safety way home' for the safety of the community, which due to fire gives alleviate the emotional anxiety of firefighters, which improve the environment for long-term control room working during decision making caused by natural disasters.

Study on the Indoor-Outdoor $NO_2$ Levels and Related Factors in Urban Apartments (도시아파트의 실내외 $NO_2$ 농도와 관련요인에 관한 연구)

  • Suh, Byung-Seong;Kim, Sung-Hwan;Kim, In-Shik;Hur, Yun-Young;Do, Sou-Young;Kim, Jung-Man;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.3 s.58
    • /
    • pp.609-622
    • /
    • 1997
  • Nitrogen dioxide $(NO_2)$ has been regarded as one of the main elements among air pollutants, and we measured $NO_2$ levels of near gas range, kitchen, living room and outdoor on 489 apartments in Pusan area. $NO_2$ were sampled by using Palmes tubes (diffusion tube sampler) during August 16-25, 1995 (summer) and January 15-29, 1996 (winter), respectively. Authors wanted to know comparison of $NO_2$ levels in summer and winter, $NO_2$ levels categorized by variables, and variables affected to $NO_2$ levels. According to this study, we conducted to establish the degree of indoor-outdoor air pollution of urban apartments in Korea and methods to reduce indoor air pollution. The results of this study were summarized as follows: 1) Mean $NO_2$ levels of near gas range, kitchen, living room, and outdoor were $25.9{\pm}10.0ppb,\;23.3{\pm}8.0ppb,\;19.9{\pm}6.1ppb,\;and\;19.0{\pm}6.0ppb$ in summer, and $34.5{\pm}16.8ppb,\;28.2{\pm}13.4ppb,\;25.3{\pm}12.5ppb,\;21.8{\pm}9.8ppb$ in winter, respectively. 2) Mean $NO_2$ levels according to the floor levels were not significantly different in summer, and in winter, $NO_2$ levels were decreased as the floor levels were increasing, but those were increased above 16th floor. 3) Variables showing significant correlation(p<0.05) with $NO_2$ levels were as follows; Summer: floor level, family size, number of family during a meal, number using gas range during rice cooking per day, and natural ventilation. Winter: floor level, family size, number of person who have been respiratory disease in a house, number of family during a meal, total number of meals, and number using gas range during rice or side-dish cooking per day. 4) We suggest that the methods of reducing indoor $NO_2$ levels are ventilation during cooking, complete combustion, decreasing number and time of cooking, and substitution of fuels.

  • PDF

A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.

Combustion of a Female Body Due to an External Ignition Source (외부 점화원에 의한 여성 신체의 연소)

  • Cho, Young Jin;Ji, Hong Keun;Kim, Sun Jae;Lim, Kyu Young;Lee, Dong Kyu;Choi, Gyeong Won;Park, Jong Taek;Moon, Byung Sun;Goh, Jae Mo;Park, Nam Kyu
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.94-96
    • /
    • 2020
  • In November 2013, a case of sustained combustion of a female body was encountered in a Korean farming village. The body was almost completely incinerated from the neck to the knees, and other parts of the body, such as the head, arms, lower legs, and feet, were slightly damaged. The most likely external ignition source was the flame from a matchstick. The elderly woman was found incinerated on the floor of the living room, while other objects in the house were largely undamaged except for having a brown oily or greasy coating. Flammable substances were not detected from the woman's intact pieces of clothing and socks, and her muscular tissues did not contain toxic chemicals. The concentration of carboxyhemoglobin in her peripheral blood was 11% and that of ethyl alcohol in her aqueous humor was below 0.010%. An autopsy failed to determine the exact cause of death because of excessive charring.

Impact of Indoor Pan-frying Cooking Activity on Change of Indoor PMPM2.5 Concentration Level in Asthmatics' Homes (천식 환자 가정 내 굽기조리 활동에 의한 실내 미세먼지(PM2.5) 농도 수준의 변화)

  • Park, Su Jung;Park, Choon sik;Lim, Dae hyun;Lee, Sang woon;Jang, So young;Yu, Sol;Kim, Sung Roul
    • Journal of Environmental Science International
    • /
    • v.29 no.1
    • /
    • pp.109-117
    • /
    • 2020
  • Asthmatics are more susceptible to fine particulate matters (PM2.5), compared to the general population. It has been reported that indoor PM2.5 is mainly generated by combustion of fossil fuels, meat or fish In particular, asthmatics are known to be more susceptible to indoor PM2.5 because 65~95% of child or adult asthmatics stay inside the house. Thus, understanding the association between indoor activity patterns and variations in indoor PM2.5 levels is important. The purpose of this study is to determine the distribution of hourly indoor PM2.5 concentrations in asthmatics' homes, and to evaluate its association with pan-frying cooking activity patterns, the most common PM2.5 emission related activity. From November 2017 to February 2018, real-time PM2.5 concentrations were measured in the living room of each asthmatic's house (n = 35) for three weeks at 1 minute intervals. At the same time, self-reported daily activity patterns, hourly proportion (%) of cooking activities, were also recorded every hour over three weeks for each patient. In this study, we provided quantitative evidence that the distribution patterns of indoor hourly PM2.5 concentrations were associated with indoor cooking activities, especially in the homes of adult asthmatics. In addition, we observed that PM2.5 emitted by pan-frying could maintain even over up to 2 hour lagtime.