• Title/Summary/Keyword: Liver, magnetic resonance imaging

Search Result 154, Processing Time 0.034 seconds

MR Study of Wate Exchange and Cell Membrane Permeability in Rat Liver Cells Using a Tissue-Specific MR Contrast Agent (조직 특성 MR 조영제를 이용한 쥐의 간세포막의 물분자 교환 및 투과율의 MR 측정기법)

  • Yongmin Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.73-82
    • /
    • 1998
  • Purpose : A precise NMR technique for measuring the rate of water exchange and cell membrane permeability across the hepatocyte membrane using liver-specific MR contrast agent is described. Materials and Methods : The rat hepatocytes isolated by perfusion of the livers were used for the NMR measurements. All experiments were performed on an IBM field cycling relaxometer operating from 0.02MHz to 60 MHz proton Larmor frequency. spin-echo pulse sequence was empolyed to measure spin-lattice relaxation time, T1. The continuous distribution analysis of water proton T1 data from rat hepatocytes containing low concentrations of the liver specific contrast agent, Gd-EOB-DTPA, modeled by a general two compartment exchange model. Results : The mean residence time of water molecule inside the hepatocyte was approximately 250 msec. The lower limit for the permeability of the hepatocyte membrane was $(1.3{\pm}0.1){\;}{\times}{\;}10^{-3}cm/sec$. The CONTIN analysis, which seeks the natural distribution of relaxation times, reveals direct evidence of the effect of diffusive exchange. the diffusive water exchange is not small in the intracellular space in the case of hepatocytes. Conclusions : Gd-EOB-DTPA, when combined with continuous distribution analysis, provides a robust method to study water exchange and membrane permeability in hepatocytes. Water exchange in hepatocyte is much slower thatn that in red blood cells. Therefore, tissue-specific contrast agent may be used as a functional agent to give physiological information such as cell membrane permeability.

  • PDF

Total Bilirubin Level as a Predictor of Suboptimal Image Quality of the Hepatobiliary Phase of Gadoxetic Acid-Enhanced MRI in Patients with Extrahepatic Bile Duct Cancer

  • Jeong Ah Hwang;Ji Hye Min;Seong Hyun Kim;Seo-Youn Choi;Ji Eun Lee;Ji Yoon Moon
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.389-401
    • /
    • 2022
  • Objective: This study aimed to determine a factor for predicting suboptimal image quality of the hepatobiliary phase (HBP) of gadoxetic acid-enhanced MRI in patients with extrahepatic bile duct (EHD) cancer before MRI examination. Materials and Methods: We retrospectively evaluated 259 patients (mean age ± standard deviation: 68.0 ± 8.3 years; 162 male and 97 female) with EHD cancer who underwent gadoxetic acid-enhanced MRI between 2011 and 2017. Patients were divided into a primary analysis set (n = 184) and a validation set (n = 75) based on the diagnosis date of January 2014. Two reviewers assigned the functional liver imaging score (FLIS) to reflect the HBP image quality. The FLIS consists of the sum of three HBP features, each scored on a 0-2 scale: liver parenchymal enhancement, biliary excretion, and signal intensity of the portal vein. Patients were classified into low-FLIS (0-3) or high-FLIS (4-6) groups. Multivariable analysis was performed to determine a predictor of low FLIS using serum biochemical and imaging parameters of cholestasis severity. The optimal cutoff value for predicting low FLIS was obtained using receiver operating characteristic analysis, and validation was performed. Results: Of the 259 patients, 140 (54.0%) and 119 (46.0%) were classified into the low-FLIS and high-FLIS groups, respectively. In the primary analysis set, total bilirubin was an independent factor associated with low FLIS (adjusted odds ratio per 1-mg/dL increase, 1.62; 95% confidence interval [CI], 1.32-1.98). The optimal cutoff value of total bilirubin for predicting low FLIS was 2.1 mg/dL with a sensitivity of 95.1% (95% CI: 88.9-98.4) and a specificity of 89.0% (95% CI: 80.2-94.9). In the validation set, the total bilirubin cutoff showed a sensitivity of 92.1% (95% CI: 78.6-98.3) and a specificity of 83.8% (95% CI: 68.0-93.8). Conclusion: Serum total bilirubin before acquisition of gadoxetic acid-enhanced MRI may help predict suboptimal HBP image quality in patients with EHD cancer.

Comparison of Image Quality in Magnetic Resonance Imaging of the Abdominal Organ at 1.5T and 3.0T before the Gadolinium Injection (조영제 주입 전 1.5T 와 3.0T를 이용한 복부장기 자기공명영상에서 영상의 질 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.619-625
    • /
    • 2017
  • The sudy was intended to evaluate the optimal equipment selection by quantitatively assessing the SNR(signal to noise ratio) and CNR(contrast to noise ratio) on the abdominal organ. This study performed on 1.5 T and 3.0 T MRI units focusing on HASTE, HASTE(f/s) and FFE(in of phase), FFE(out of phase) without using the contrast medium(Gadolinium). The data analysis was performed by randomly selecting on 1.5 T and 3.0 T abdominal MRI images. As a results, SNR and CNR values of 3.0 T is higher than 1.5 T at liver, kidney and spleen(p<0.05). Stomach, abdominal fat and pancreas was obtained a higher value at 1.5 T(p<0.05). On conclusion, the organs of outer part in the body showed generally a high value at 3.0 T, and the organs of inner part in the body including the gas showed a high value at 3.0 T because of a large difference on magnetic susceptibility.

Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breath-hold Imaging Sequences (간의 3T 자기공명영상에서 초상자성산화철 조영증강 급속호흡정지영상기법들간의 양적 및 질적 비교평가)

  • Cho, Kyung-Eun;Yu, Jeong-Sik;Chung, Jae-Joon;Kim, Joo-Hee;Kim, Ki-Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.31-40
    • /
    • 2010
  • Purpose : To compare the relative values of various fast breath-hold imaging sequences for superparamagnetic iron-oxide (SPIO)-enhanced hepatic MRI for the assessment of solid focal lesions with a 3T MRI unit. Materials and Methods : 102 consecutive patients with one or more solid malignant hepatic lesions were evaluated by spoiled gradient echo (GRE) sequences with three different echo times (2.4 msec [GRE_2.4], 5.8 msec [GRE_5.8], and 10 msec [GRE_10]) for $T2^*$-weighted imaging in addition to T2-weighted turbo spin echo (TSE) sequence following intravenous SPIO injection. Image qualities of the hepatic contour, vascular landmarks and artifacts were rated by two independent readers using a four-point scale. For quantitative analysis, contrast-to-noise ratio (CNR) was measured in 170 solid focal lesions larger than 1 cm (107 hepatocellular carcinomas, nine cholangiocarcinomas and 54 metastases). Results : GRE_5.8 showed the highest mean points for hepatic contour, vascular anatomy and imaging artifact presence among all of the subjected sequences (p<0.001) and was comparable (p=0.414) with GRE_10 with regard to lesion conspicuity. The mean CNRs were significantly higher (p<0.001) in the following order: GRE_10 ($24.4{\pm}14.5$), GRE_5.8 ($14.8{\pm}9.4$), TSE ($9.7{\pm}6.3$), and GRE_2.4 ($7.9{\pm}6.4$). The mean CNRs of CCCs and metastases were higher than those of HCCs for all imaging sequences (p<0.05). Conclusion : Regarding overall performances, GRE using a moderate echo time of 5.8 msec can provide the most reliable data among the various fast breath-hold SPIO-enhanced hepatic MRI sequences at 3T unit despite the lower CNR of GRE_5.8 compared to that of GRE_10.

Relationship between liver iron concentration determined by R2-MRI, serum ferritin, and liver enzymes in patients with thalassemia intermedia

  • Al-Momen, Hayder;Jasim, Shaymaa Kadhim;Hassan, Qays Ahmed;Ali, Hayder Hussein
    • BLOOD RESEARCH
    • /
    • v.53 no.4
    • /
    • pp.314-319
    • /
    • 2018
  • Background Iron overload is a risk factor affecting all patients with thalassemia intermedia (TI). We aimed to determine whether there is a relationship of serum ferritin (SF) and alanine aminotransferase (ALT) with liver iron concentration (LIC) determined by R2 magnetic resonance imaging (R2-MRI), to estimate the most relevant degree of iron overload and best time to chelate in patients with TI. Methods In this cross-sectional study, 119 patients with TI (mean age years) were randomly selected and compared with 120 patients who had a diagnosis of thalassemia major (TM). Correlations of LIC, as determined by R2-MRI, with SF and ALT levels, were assessed in all participants. A P-value <0.05 was considered statistically significant. Results SF and LIC levels were lower in patients with TI than in those with TM; only ferritin values were significant. We found a statistically significant relationship between SF and LIC, with cut-off estimates of SF in patients with TI who had splenectomy and those who entered puberty spontaneously (916 and 940 ng/mL, respectively) with LIC >5 mg Fe/g dry weight (P<0.0001). A significant relationship was also found for patients with TI who had elevated ALT level (63.5 U/L), of 3.15 times the upper normal laboratory limit, using a cut-off for LIC ${\geq}5mg\;Fe/g\;dry\;weight$. Conclusion We determined the cut-off values for ALT and SF indicating the best time to start iron chelation therapy in patients with TI, and found significant correlations among iron overload, SF, and ALT.

Intraindividual Comparison of Hepatocellular Carcinoma Washout between MRIs with Hepatobiliary and Extracellular Contrast Agents

  • Yeun-Yoon Kim;Young Kon Kim;Ji Hye Min;Dong Ik Cha;Jong Man Kim;Gyu-Seong Choi;Soohyun Ahn
    • Korean Journal of Radiology
    • /
    • v.22 no.5
    • /
    • pp.725-734
    • /
    • 2021
  • Objective: To intraindividually compare hepatocellular carcinoma (HCC) washout between MRIs using hepatobiliary agent (HBA) and extracellular agent (ECA). Materials and Methods: This study included 114 prospectively enrolled patients with chronic liver disease (mean age, 55 ± 9 years; 94 men) who underwent both HBA-MRI and ECA-MRI before surgical resection for HCC between November 2016 and May 2019. For 114 HCCs, the lesion-to-liver visual signal intensity ratio (SIR) using a 5-point scale (-2 to +2) was evaluated in each phase. Washout was defined as negative visual SIR with temporal reduction of visual SIR from the arterial phase. Illusional washout (IW) was defined as a visual SIR of 0 with an enhancing capsule. The frequency of washout and MRI sensitivity for HCC using LR-5 or its modifications were compared between HBA-MRI and ECA-MRI. Subgroup analysis was performed according to lesion size (< 20 mm or ≥ 20 mm). Results: The frequency of portal venous phase (PP) washout with HBA-MRI was comparable to that of delayed phase (DP) washout with ECA-MRI (77.2% [88/114] vs. 68.4% [78/114]; p = 0.134). The frequencies were also comparable when IW was allowed (79.8% [91/114] for HBA-MRI vs. 81.6% [93/114] for ECA-MRI; p = 0.845). The sensitivities for HCC of LR-5 (using PP or DP washout) were comparable between HBA-MRI and ECA-MRI (78.1% [89/114] vs. 73.7% [84/114]; p = 0.458). In HCCs < 20 mm, the sensitivity of LR-5 was higher on HBA-MRI than on ECA-MRI (70.8% [34/48] vs. 50.0% [24/48]; p = 0.034). The sensitivity was similar to each other if IW was added to LR-5 (72.9% [35/48] for HBA-MRI vs. 70.8% [34/48] for ECA-MRI; p > 0.999). Conclusion: Extracellular phase washout for HCC diagnosis was comparable between MRIs with both contrast agents, except for tumors < 20 mm. Adding IW could improve the sensitivity for HCC on ECA-MRI in tumors < 20 mm.

The Effect of Gd-EOB-DPTA on the Stiffness Value of Magnetic Resonance Elastography in Evaluating Hepatic Fibrosis (간 섬유화 평가를 위한 MR elastography의 경직도에 대한 Gd-EOB-DTPA의 영향)

  • Lee, Jeong Eun;Lee, Jeong Min;Lee, Ye Ji;Yoon, Jeong-Hee;Lee, Kyung Bun;Han, Joon Koo;Choi, Byung Ihn
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.215-223
    • /
    • 2013
  • Purpose : To evaluate the effect of gadoxetic acid on the measurement of the stiffness value of MR elastography (MRE) used to evaluate hepatic fibrosis (HF). Materials and Methods: MRE was obtained in 32 patients with clinically suspected chronic liver disease, both before and after injection of gadoxetic acid. Two independent reviewers measured the stiffness values of the liver parenchyma on elastograms. The mean liver stiffness values were compared in the pre- and post-contrast MREs using the paired t-test. Intra-rater and inter-rater correlation was assessed using the intraclass correlation coefficient (ICC). The accuracy, sensitivity, and specificity of both pre- and post-contrast MREs was evaluated for the diagnosis of significant HF (${\geq}F2$) using cut off value of 3.1 kPa. Results: There were no significant differences in the stiffness values of the liver parenchyma on pre- and post-contrast MREs (p = 0.15 and 0.38 for each reader, respectively). Regarding intra-rater correlation, excellent agreement was noted on rater 1(ICC = 0.998) and rater 2 (ICC = 0.996). Excellent correlation regarding the measured stiffness values was noted on both pre- and post-contrast MREs (ICC = 0.988 for pre-contrast, ICC = 0.993 for post-contrast). The accuracy, sensitivity, and specificity of the pre- and post-contrast MREs for differentiating significant HF (${\geq}F2$) from ${\geq}F1$ were same as 71%, 60%, and 100%, respectively. Conclusion: As there was no significant difference in the stiffness measurements seen on MREs before and after administration of gadoxetic acids, it is therefore acceptable to perform MRE after contrast injection in order to evaluate HF.

Overlooked and Challenging Encounters-Inflammatory Pseudotumors in the Abdomen and Pelvis: A Pictorial Essay (놓치기 쉽고 진단이 어려운 복부골반강의 염증성 가성 종양: 임상화보)

  • Min Ha Kwag;Jin Young Park;Hae Woong Jeong;Ji Yeon Han;Jong Heon Lim;Young Seon Kim;Jung Won Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1121-1133
    • /
    • 2020
  • Inflammatory pseudotumors (IPTs) are uncommon, mass-forming lesions, predominantly involving the lung and orbit. Although the incidence of IPTs is rare in the abdomen and pelvis, they can be encountered as enhancing, soft-tissue lesions, mimicking malignancy or fibrosclerosing disease. Generally, they exhibit a wide range of nonspecific imaging features in various organs. Preoperative imaging diagnosis of IPTs in appropriate clinical settings may help determine proper patient management. In this article, we review radiologic findings of IPTs in the abdominopelvic cavity, including the liver, spleen, kidney, gastrointestinal tract, mesentery, pelvis, and retroperitoneum.

Usefulness of Arterial Subtraction in Applying Liver Imaging Reporting and Data System (LI-RADS) Treatment Response Algorithm to Gadoxetic Acid-Enhanced MRI

  • Seo Yeon Youn;Dong Hwan Kim;Joon-Il Choi;Moon Hyung Choi;Bohyun Kim;Yu Ri Shin;Soon Nam Oh;Sung Eun Rha
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1289-1299
    • /
    • 2021
  • Objective: We aimed to evaluate the usefulness of arterial subtraction images for predicting the viability of hepatocellular carcinoma (HCC) after locoregional therapy (LRT) using gadoxetic acid-enhanced MRI and the Liver Imaging Reporting and Data System treatment response (LR-TR) algorithm. Materials and Methods: This study included 90 patients (mean age ± standard deviation, 57 ± 9 years) who underwent liver transplantation or resection after LRT and had 73 viable and 32 nonviable HCCs. All patients underwent gadoxetic acid-enhanced MRI before surgery. Two radiologists assessed the presence of LR-TR features, including arterial phase hyperenhancement (APHE) and LR-TR categories (viable, nonviable, or equivocal), using ordinary arterial-phase and arterial subtraction images. The reference standard for tumor viability was surgical pathology. The sensitivity of APHE for diagnosing viable HCC was compared between ordinary arterial-phase and arterial subtraction images. The sensitivity and specificity of the LR-TR algorithm for diagnosing viable HCC was compared between the use of ordinary arterial-phase and the use of arterial subtraction images. Subgroup analysis was performed on lesions treated with transarterial chemoembolization (TACE) only. Results: The sensitivity of APHE for viable HCCs was higher for arterial subtraction images than ordinary arterial-phase images (71.2% vs. 47.9%; p < 0.001). LR-TR viable category with the use of arterial subtraction images compared with ordinary arterial-phase images showed a significant increase in sensitivity (76.7% [56/73] vs. 63.0% [46/73]; p = 0.002) without significant decrease in specificity (90.6% [29/32] vs. 93.8% [30/32]; p > 0.999). In a subgroup of 63 lesions treated with TACE only, the use of arterial subtraction images showed a significant increase in sensitivity (81.4% [35/43] vs. 67.4% [29/43]; p = 0.031) without significant decrease in specificity (85.0% [17/20] vs. 90.0% [18/20]; p > 0.999). Conclusion: Use of arterial subtraction images compared with ordinary arterial-phase images improved the sensitivity while maintaining specificity for diagnosing viable HCC after LRT using gadoxetic acid-enhanced MRI and the LR-TR algorithm.

Evaluation of Automatic Image Segmentation for 3D Volume Measurement of Liver and Spleen Based on 3D Region-growing Algorithm using Animal Phantom (간과 비장의 체적을 구하기 위한 3차원 영역 확장 기반 자동 영상 분할 알고리즘의 동물팬텀을 이용한 성능검증)

  • Kim, Jin-Sung;Cho, June-Sik;Shin, Kyung-Sook;Kim, Jin-Hwan;Jeon, Ho-Sang;Cho, Gyu-Seong
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.178-185
    • /
    • 2008
  • Living donor liver transplantation is increasingly performed as an alternative to cadaveric transplantation. Preoperative screening of the donor candidates is very important. The quality, size, and vascular and biliary anatomy of the liver are best assessed with magnetic resonance (MR) imaging or computed tomography (CT). In particular, the volume of the potential graft must be measured to ensure sufficient liver function after surgery. Preoperative liver segmentation has proved useful for measuring the graft volume before living donor liver transplantations in previous studies. In these studies, the liver segments were manually delineated on each image section. The delineated areas were multiplied by the section thickness to obtain volumes and summed to obtain the total volume of the liver segments. This process is tedious and time consuming. To compensate for this problem, automatic segmentation techniques have been proposed with multiplanar CT images. These methods involve the use of sequences of thresholding, morphologic operations (ie, mathematic operations, such as image dilation, erosion, opening, and closing, that are based on shape), and 3D region growing methods. These techniques are complex but require a few computation times. We made a phantom for volume measurement with pig and evaluated actual volume of spleen and liver of phantom. The results represent that our semiautomatic volume measurement algorithm shows a good accuracy and repeatability with actual volume of phantom and possibility for clinical use to assist physician as a measuring tool.

  • PDF