• Title/Summary/Keyword: Lissajous Signal

Search Result 10, Processing Time 0.027 seconds

A Practical Method of Balancing a Rigid Rotor

  • Su, Hua;Chong, Kil-To
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.36-40
    • /
    • 2006
  • Diagnosis and repair tasks of an unbalanced rigid rotor reduce the chances of unexpected failure and the consequent losses in production, time, and money. This paper presents investigation of a balancing system for equilibration of rigid rotor unbalance. A practical vibration signal based method is developed for unbalance diagnosis using wavelet technology and a Lissajous diagram. This paper shows that a mass unbalance can be efficiently estimated through an appropriate narrow-band filter used to extract the required spectra component. The wavelet technology is used to design specified narrow filter bank. A modified Lissajous diagram is also introduced with statistical analysis to compute the phase position. Several experimental tests demonstrate the effectiveness in balancing the mass unbalance of a rigid rotor.

A Real-Time DSP-Based Imbalance Analysis System for Rotating Machine with Vibration Signal

  • Su Hua;Huang Linglong;Chong Kil To
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.1243-1252
    • /
    • 2005
  • This paper describes a new digital signal processor (DSP) imbalance measurement system dedicated to real-time vibration analysis on rotating machine. To accomplish real-time analysis, the vibration signals are on-line acquired and processed to analyze the mass imbalance and phase position. This is achieved through the use of FFT and Lissajous diagram. The method followed to analyze the mass imbalance with the chosen hardware and software solutions are described in detail in this paper. Several experimental tests demonstrate the efficiency and accuracy in imbalance analysis performance of the DSP system.

Quadrature-detection-error Compensation in a Sinusoidally Modulated Optical Interferometer Using Digital Signal Processing

  • Hwang, Jeong-hwan;Park, Chang-Soo
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.204-209
    • /
    • 2019
  • In an optical interferometer that uses sinusoidal modulation and quadrature detection, the amplitude and offset of the interference signal vary with time, even without considering system noise. As a result, the circular Lissajous figure becomes elliptical, with wide lines. We propose and experimentally demonstrate a method for compensating quadrature detection error, based on digital signal processing to deal with scaling and fitting. In scaling, fluctuations in the amplitudes of in-phase and quadrature signals are compensated, and the scaled signals are fitted to a Lissajous unit circle. To do so, we scale the average fluctuation, remove the offset, and fit the ellipse to a unit circle. Our measurements of a target moving with uniform velocity show that we reduce quadrature detection error from 5 to 2 nanometers.

An Efficient Method for the Mass Unbalance Analysis of a Rotor System Using FFT and Lissajous Diagram

  • Su, Hua;Chong, Kil-To
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1612-1617
    • /
    • 2004
  • Unbalance analysis is essential in the rotor system. However, some problems still remain in the aspects of computational efficiency and accuracy. In the present paper a new method is proposed for estimating the mass unbalance of a rotating shaft by using the vibration signals. This is an advanced new method for the detection of a mass unbalance and its phase position. Based on the signal processing with FFT, an estimator is designed to detect the mass of unbalance. And an improved Lissajous diagram is also introduced with statistical analysis, which make it possible to compute the phase position of the mass unbalance efficiently and arranged at a certain location of the shaft. The proposed method is demonstrated and validated through several test examples.

  • PDF

Simulation of Eddy Current Testing Signals Using Simulation Software Dedicated to Nondestructive Testing (비파괴검사 전용 시뮬레이터를 이용한 와전류검사 신호 시뮬레이션)

  • Lee, Tae-Hun;Cho, Chan-Hee;Lee, Hee-Jong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.75-81
    • /
    • 2014
  • A simulation of eddy current testing has been utilized for predicting the signal characteristics to the various defects and developing the probes. Especially, CIVA which is a simulation tool dedicated to nondestructive testing has a good accuracy and speed, and provides a three-dimensional graphical user interface for improved visualization and familiar data displays consistent with NDE technique. Although internal validations have been performed by the CIVA software development specialists, an independent validation study is necessary for the accuracy assessment of the software prior to practical use. For this purpose, in this study, eddy current testing signals of ASME FBH calibration standard tube for bobbin probe were simulated using CIVA and the results were compared to the experimental inspected signals based on the relationship between each flaw signal in terms of amplitude and phase, and the shape of the Lissajous curve. And then we verified the accuracy of the simulated signals and the possible range for simulation. Overall, there is a good qualitative agreement between the CIVA simulated and experimental results in the absolute and differential modes at the two inspection frequencies.

Variation of Eddy Current Signal According to the Defect Shape, Defect Depth and Radial Load in CFRP Tube (CFRP 튜브의 결함형상.결함깊이.레이디얼 하중에 따른 와전류 신호의 변화)

  • 송삼홍;안형근;이정순;오동준;송일;김철웅
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.2004-2011
    • /
    • 2004
  • The applicability of the ultrasonic C-scan inspection is restricted due to the deterioration of mechanical properties of specimen during the test. Therefore, the aim of this research is applied to Eddy Current (EC) test substitute for the C-scan inspection in CFRP tube containing defects. This research is to evaluate the EC signals for the inspection of CFRP tube containing various circular hole defects (20% to 100% depth to the specimen thickness) using the unloading specimen and radial loading specimen. This study was considered the following points; 1) Analysis of EC signals for the inspection of saw-cut defect and circular hole defect, 2) The evaluation of defect depths and EC signals relationship. 3) Variation of EC signal owing to the radial load. In conclusions, the high frequency such as 300∼500 kHz made it possible to the inspection of 40% to 100% defects. Particularly, in case of 20% defect, the EC signal was not detected due to the noise of micro-crack and delamination. While the depth of the hole defects were decreasing, the difference of the phase angle between unloading specimen and radial loading specimen was gradually increasing.

$LP_{11}$ Mode Fiber Optic Resonant Ring Interferometer with a $LP_{11}$ Modal Filter ($LP_{11}$ 결모양 빛살거르게를 사용한 $LP_{11}$ 결모양 빛살 광섬유 공진고리 간섭계)

  • 이현재;이두희;서상준;양진성
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.20-25
    • /
    • 1991
  • Using evanescent field coupling between single ($LP_{01}$) and double ($LP_{01}, LP_{11}$) mode optical fiber, we selected LPII mode beam. With a $LP_{11}$ mode beam from a double mode fiber. we fabricated $LP_{11}$ mode fiber optic resonant ring interferometer, and assured that the guided mode is $LP_{11}$ mode from a radiation beam coming through the prism output coupler. When an external perturbation applied to the signal arm of the $LP_{11}$ fiber optic resonant ring interferometer, we examined the change of radiation mode coming from a prism output coupler and an end of optical fiber. Using two photodiode, LPn mode beam converted to voltage. This two output voltages is applied to X and Y terminal of oscilloscope to display circular motion on oscilloscope.

  • PDF

Development of a Multichannel Eddy Current Testing Instrument(I) (다중채널 와전류탐상검사 장치 개발(I))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoon, Byung-Sik;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.155-161
    • /
    • 2010
  • Recently, the electromagnetic techniques of the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In this study, the synthesizer module and the analog module which are essential to the ECT system were primarily developed. The developed ECT system is basically a multifrequency type which is able to inject the maximum four frequencies based on the frequency and time domain multiplexing method. Conclusively, we confirmed that the EC signal was processed appropriately in each circuit modules, and the Lissajous EC signal was displayed in the impedance plane.

Development of a Multichannel Eddy Current Testing Instrument(II) (다중채널 와전류탐상검사 장치 개발(II))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoo, Hyun-Joo;Kim, In-Chel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.552-559
    • /
    • 2011
  • Recently, the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction phenomenon. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In the previous study, the synthesizer module and the analog module which is essential to the ECT system were primarily developed, and in this study the data acquisition and analysis program were developed. The operation system for this program is based on the Windows 7, and optimized for the Korean users, and the specific feature of this program using setup wizard enables inspector to make a setup easily for acquisition and analysis of ECT data. In this paper, the configuration and functions of eddy current data acquisition and analysis program will be introduced.