• 제목/요약/키워드: Liquid-vapor interface

검색결과 82건 처리시간 0.025초

인공신경망을 통한 2D 용질성 마랑고니 유동 액적의 용질 농도 분포 역추적 기법 (Reverse tracking method for concentration distribution of solutes around 2D droplet of solutal Marangoni flow with artificial neural network)

  • 김준규;류준일;김형수
    • 한국가시화정보학회지
    • /
    • 제19권2호
    • /
    • pp.32-40
    • /
    • 2021
  • Vapor-driven solutal Marangoni flow is governed by the concentration distribution of solutes on a liquid-gas interface. Typically, the flow structure is investigated by particle image velocimetry (PIV). However, to develop a theoretical model or to explain the working mechanism, the concentration distribution of solutes at the interface should be known. However, it is difficult to achieve the concentration profile theoretically and experimentally. In this paper, to find the concentration distribution of solutes around 2D droplet, the reverse tracking method with an artificial neural network based on PIV data was performed. Using the method, the concentration distribution of solutes around a 2D droplet was estimated for actual flow data from PIV experiment.

Leidenfrost 온도 이상의 가열 벽면과 충돌 시 열전달에 대한 액적 온도의 영향 (Effects of Droplet Temperature on Heat Transfer During Collision on a Heated Wall Above the Leidenfrost Temperature)

  • 박준석;김형대
    • 한국분무공학회지
    • /
    • 제21권2호
    • /
    • pp.78-87
    • /
    • 2016
  • This study experimentally investigated the effects of droplet temperature on the heat transfer characteristics during collision of a single droplet on a heated wall above the Leidenfrost temperature. Experiments were performed by varying temperature from 40 to $100^{\circ}C$ while the collision velocity and wall temperature were maintained constant at 0.7 m/s at $500^{\circ}C$, respectively. Evolution of temperature distribution at the droplet-wall interface as well as collision dynamics of the droplet were simultaneously recorded using synchronized high-speed video and infrared cameras. The local heat flux distribution at the collision surface was deduced using the measured temperature distribution data. Various physical parameters, including residence time, local heat flux distribution, heat transfer rate, heat transfer effectiveness and vapor film thickness, were measured from the visualization data. The results showed that increase in droplet temperature reduces the residence time and increases the vapor film thickness. This ultimately results in reduction in the total heat transfer by conduction through the vapor film during droplet-wall collision.

삼각단면 극소히트파이프의 작동특성에 관한 기초 연구 (Fundamental study on performance characteristics of a micro heat pipe with triangular cross section)

  • 문석환;김종오;김철주
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.176-184
    • /
    • 1999
  • Numerical and experimental studies were performed to examine the characteristics of heat and mass transfer processes for a Micro Heat Pipe(MHP) with a triangular cross-section. Solutions on mass flow rate, pressure variation, and radius of meniscus were obtained using the mathematical model developed by Faghri and Khrustalev. To obtain an increase in capillary limitation, a triangular tube with curved walls was designed and fabricated. The measurement by microscope showed that the radius at corners of the tube was ranging between 0.03-0.05mm. Performance test for MHPs using the triangular tube with curved walls proved a substantial increasement in heat transport limitation, with 4.5W and 2.0W in case of using water and ethanol as a working fluid, respectively. In the previous study by Faghri a limitation of 0.5W was reported for a water MHP with a regular triangular tube.

  • PDF

Heat Transfer Correlation to Predict the Evaporation of a Water Droplet in Superheated Steam during Reflood Phase of a LOCA

  • Kim, Yoo;Ban, Chang-Hwan
    • 에너지공학
    • /
    • 제9권3호
    • /
    • pp.261-268
    • /
    • 2000
  • A heat transfer correlation to predict the vaporization of a water droplet in highly superheated steam during a loss-of-coolant accident(LOCA) of a nuclear power plant is provided. Vaporization of liquid fuel or water droplets in superheated air or steam and subsequent interface heat transfer between a liquid droplet and superheated gas is typically correlated by way of a Nusselt number as a function of Reynolds number, Prantl number, and in some cases including mass transfer number. Presently available correlations and experimental data of the evaporation of liquid droplets in air or steam are analyzed and a new Nusselt number correlation is proposed taking Schmidt number into consideration in order to account for binary diffusion of the vapor as well, Nu$\_$f/(1+B)$\^$0.7/=2+0.53Sc$\_$f/$\^$-1/5/Re$\_$M/$\^$$\sfrac{1}{2}$/Pr$\_$f/$\^$$\sfrac{1}{3}$/ for which properties are evaluated at film condition except the density of Reynolds number evaluated at ambient condition. Diverse correlations for various combinations of liquid and gas species are put into single equation. The blowing correction factor of (1+B)$\^$0.7/ is confirmed appropriate, and a criterion to distinguish so-called high- and low-temperature condition of ambient gas is set forth.

  • PDF

흡수성능에 미치는 수직 액막 파동의 영향에 관한 연구 (Effect of Wavy Flow of Vertical Falling Film on the Absorption Performance)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.194-201
    • /
    • 2004
  • In the present study, the improvement of absorption characteristics on combined heat and mass transfer process in a falling film of a vertical absorber by change of geometric parameters were studied experimentally and analytically. The energy and diffusion equations are solved simultaneously to give the temperature and concentration variations at the liquid solution-refrigerant vapor interface and at the wall. Absorption behaviors of heat and mass transfer were analyzed through falling film of the LiBr aqueous solution contacted by refrigerant vapor in the absorber. Effects of film Reynolds number, geometric parameters by insert device (spring) and flow pattern on heat and mass transfer performances have been also investigated. Especially, effects of the flow pattern by geometric parameters have been considered to observe the total heat and mass transfer rates through falling film along the absorber. As a numerical and experimental result, maximum absorption rate was shown at the wave-flow by insert device (spring). The error ranges between experiment and analysis were from 5.8 to 12% at Re$_{f}$ > 100.0.

다공층의 증발냉각 열전달에 관한 해석적 연구 (Analytical Study of heat Transfer in Evaporative Cooling of a Porous Layer)

  • 김홍제;이진호
    • 대한기계학회논문집
    • /
    • 제16권1호
    • /
    • pp.104-111
    • /
    • 1992
  • 본 연구에서는 외부 열입력(external heat input)의 조건하에서 증발분출냉각 시스템에서 나타나는 3개의 영역, 즉 증기, 증발 및 액체영역을 고려한 이론해석을 행 함으로써 증발분출냉각 시스템의 열전달 특성을 정성적으로 조사하고자 하였다.

과냉 비등유동에 대한 CFD 모의 계산에서의 벽 인접격자 영향 (NEAL-WALL GRID DEPENDENCY OF CFD SIMULATION FOR A SUBCOOLED BOILING FLOW)

  • 인왕기;신창환;전태현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.320-325
    • /
    • 2010
  • A multiphase CFD analysis is performed to investigate the effect of near-wall grid for simulating a subcooled boiling flow in vertical tube. The multiphase flow model used in this CFD analysis is the two-fluid model in which liquid(water) and vapor(steam) are considered as continuous and dispersed fluids, respectively. A wall boiling model is also used to simulate the subcooled boiling heat transfer at the heated wall boundary. The diameter and heated length of tube are 0.0154 m and 2 m, respectively. The system pressure in tube is 4.5 MPa and the inlet subcooling is 60 K. The near-wall grid size in the non-dimensional wall unit ($y_{w}^{+}$) was examined from 64 to 172 at the outlet boundary. The CFD calculations predicted the void distributions as well as the liquid and wall temperatures in tube. The predicted axial variations of the void fraction and the wall temperature are compared with the measured ones. The CFD prediction of the wall temperature is shown to slightly depend on the near-wall grid size but the axial void prediction has somewhat large dependency. The CFD prediction was found to show a better agreement with the measured one for the large near-wall grid, e.g., $y_{w}^{+}$ > 100.

  • PDF

히트 파이프의 작동유체 충전량이 성능에 미치는 영향 (Effect of Quantity of Working Fluid on Performance of a Heat Pipe)

  • 신동렬;노승탁
    • 설비공학논문집
    • /
    • 제1권4호
    • /
    • pp.313-318
    • /
    • 1989
  • Experiments have been performed to find an optimum filling quantity of working fluid in a heat pipe. The optimum operation has been defined to give a minimum temperature difference between evaporator and condenser. The experimental results show that there exists an optimum filling quantity which is slightly smaller than that calculated by the well known formula from the geometry of the wick. When the concaved vapor-liquid interface at the wick is taken into account to calculate the required quantity of working fluid, the computed value agrees with the experimentally determined quantity.

  • PDF

Measurements of the Diamagnetic Susceptibility of NaCl Aqueous Solution

  • Lee, Seung-Hwan
    • 한국항해항만학회지
    • /
    • 제27권6호
    • /
    • pp.669-675
    • /
    • 2003
  • Using a SQUID magnetometer, the diamagnetic susceptibility of NaCl aqueous solution was measured with high accuracy in a magnetic field of up to 6 Tat 25$\pm0.05^{\circ}C$. The NaCl concentrations adopted in this experiment were 0 (water), 7.5, 15, 23, 26.2, 26.6 and 100% (crystal) with the concentration error of $\pm$0.04%. Experimental data was compared with the calculated value of susceptibility derived from dependence of the vapor pressure on NaCl concentration As a result, our measured value was almost in accordance with the calculated value. It was found that the diamagnetic susceptibility shows a decrease of approximately 10% within the saturated concentration (26.2%) and that the susceptibility is one of the effective cause for the concentration dependence in the gas-liquid interface deformation of the NaCl solution.

병렬 미세관 흐름비등의 유동특성 및 열전달 향상에 대한 수치적 연구 (Numerical Study on Flow and Heat Transfer Enhancement during Flow Boiling in Parallel Microchannels)

  • 전진호;이우림;서영호;손기헌
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.472-473
    • /
    • 2008
  • Flow boiling in parallel microchannels has received attention as an effective heat sink mechanism for power-densities encountered in microelectronic equipment. the bubble dynamics coupled with boiling heat transfer in microchannels is still not well understood due to the technological difficulties in obtaining detailed measurements of microscale two-phase flows. In this study, complete numerical simulation is performed to further clarify the dynamics of flow boiling in microchannels. The level set method for tracking the liquid-vapor interface is modified to include the effects of phase change and contact angle. The method is further extended to treat the no-slip and contact angle conditions on the immersed solid. Also, the reverse flow observed during flow boiling in parallel microchannels has been investigated. Based on the numerical results, the effects of channel shape and inlet area restriction on the bubble growth, reverse flow and heat transfer are quantified.

  • PDF