Computational and Experimental Analyses of the Wave Propagation Through a Bar Structure Including Liquid-Solid Interface (액체-고체 경계면이 존재하는 구조물에서의 파동 전파 해석 및 실험)

  • Park, Sangjin;Rhee, Huinam;Yoon, Doo Byung;Park, Jin Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.793-799
    • /
    • 2015
  • In this research, we study the propagation of longitudinal and transverse waves through a metal rod including a liquid layer using computational and experimental analyses. The propagation characteristics of longitudinal and transverse waves obtained by the computational and experimental analyses were consistent with the wave propagation theory for both cases, that is, the homogeneous metal rod and the metal rod including a liquid layer. The fluid-structure interaction modeling technique developed for the computational wave propagation analysis in this research can be applied to the more complex structures including solid-liquid interfaces.

Simultaneous Analysis of Pesticide Priority Pollutants in Water Samples (수질 시료 중의 Pesticide Priority Pollutants 동시분석에 관한 연구)

  • Kim Kye-Young;Kim Chong-Hyeak;Lee Sueg-Geun
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.590-598
    • /
    • 1993
  • The simultaneous analysis of samples, 16 organic pesticides in water among 129 priority pollutants listed by EPA, was performed by GC-ECD (electron capture detector) and GC/MS-SIM (selected ion monitoring). Two extraction procedures, liquid-liquid extraction (LLE) and solid-phase extraction (SPE), were studied as an extraction and concentration method. Accuracy and precision of the methods were measured by the calculation of mean recovery and mean relative standard deviation. Finally, the detection limits, the experimental limitations, and prospects were discussed.

  • PDF

Comparison of Liquid-Liquid Extraction and Solid-Phase Extraction Coupled with GC/MS for Determination of Priority Pollutants in Water (액체 추출법과 고체상 추출법에 의한 수질 중 유해물질 농축법 비교)

  • Yook, Keun-Sung;Hong, Sa-Moon;Kim, Jong-Ho
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.441-453
    • /
    • 1994
  • Two extraction methods, liquid-liquid extraction(LLE) and solid-phase extraction(SPE), coupled with GC/MS were compared as preconcentration procedures for priority pollutants in water. Among the semi-volatile priority pollutants, 11 acid and 44 base/neutral compounds were spiked in reagent water. With LLE, which is a modification of EPA Method 625, the overall mean recovery of the 54 compounds was 91% with a mean relative standard deviation(RSD) of 4.6%. With SPE, the overall mean recovery of the 52 compounds was 53% with a mean RSD of 8.9%. The detection limits of both methods were in the range of $1{\sim}5{\mu}g/l$.

  • PDF

Fabrication and Evaluation of Colloidal Silica Containing Powders for Solid Self-emulsifying Drug Delivery System of Poorly Water Soluble Rivaroxaban (난용성 리바록사반 약물의 자가 유화 시스템 분말 제조를 위한 콜로이드 실리카 함유 분말의 제조 및 평가)

  • Sung Giu Jin
    • Journal of Powder Materials
    • /
    • v.30 no.4
    • /
    • pp.305-309
    • /
    • 2023
  • This study aims to prepare a colloidal silica-containing powder to enhance the solubility and dissolution rate of rivaroxaban using a self-nanoemulsifying drug delivery system (SNEDDS). We investigate the impact of colloidal silica on a nanoemulsion system for preparing powdered SNEDDS. The liquid SNEDDS comprises 30/20/50 (w/w/w) Peceol/Cremophor RH40/Tween 80, which results in the formation of the smallest droplets. Three powdered SNEDDS formulations are prepared by suspending the liquid SNEDDS formulation using colloidal silica and spray drying. The powdered SNEDDS prepared with liquid SNEDDS and colloidal silica at a ratio of 1/0.5 (w/w) exhibits the highest water solubility (0.94 ± 0.62 vs. 26.70 ± 1.81 ㎍/mL) and dissolution rate (38.4 ± 3.6 vs. 85.5 ± 3.4%, 45 min) when compared to the drug alone. Morphologically, the liquid SNEDDS is adsorbed onto colloidal silica and forms smaller particles. In conclusion, an SNEDDS containing rivaroxaban, prepared using colloidal silica, facilitates the creation of a nanoemulsion and enhances the water solubility of rivaroxaban. Accordingly, this technology holds significant potential for commercialization.

Evaluation of Patterns and Binding Forces of Tablets in Dissolution Processes

  • Kim, Jung-Woo
    • Journal of Pharmaceutical Investigation
    • /
    • v.15 no.2
    • /
    • pp.45-52
    • /
    • 1985
  • For the model tablets using mannitol and Avicel PH 101 as excipients, the patterns of disintegration and dissolution from the differences of physical properties were investigated. It was found that the patterns in the dissolution and binding forces in the interaction of materials by estimates of solid-solid or liquid surface free energy due to cohesive or adhesive properties of materials, and solid surface free energy in binding forces of tablet should be considered as an important factor in dissolution processes.

  • PDF

Numerical Study of Interfacial Flows With Immersed Solids (잠겨진 물체를 포함하는 계면유동의 수치적인 연구)

  • Kim, Sung-Il;Son, Gi-Hun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.706-711
    • /
    • 2003
  • A numerical method is presented for computing unsteady incompressible two-phase flows with immersed solids. The method is based on a level set technique for capturing the phase interface, which is modified to satisfy a contact angle condition at the solid-fluid interface as well as to achieve mass conservation during the whole calculation procedure. The modified level set method is applied for numerical simulation of bubble deformation in a micro channel with a cylindrical solid block and liquid jet from a micro nozzle.

  • PDF

A Study of Analytical Method for Trace Metal Ions in Whole Blood and Urine by Inductively Coupled Plasma-Mass Spectrometry using Solid-Liquid Extraction Technique (유도결합 플라스마-질량분석법과 고체-액체 추출법을 이용한 혈액 및 소변중 미량금속의 분석에 관한 연구)

  • Lee, Won;Hur, Young-Hoe;Park, Kyung-Su
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.281-291
    • /
    • 1998
  • An analytical method for the simultaneous measurement of trace Cu, Sn, and Bi in blood and urine has been investigated by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Microwave oven was used for the pretreatment of blood samples using nitric acid and hydrogen peroxide in a closedvessel digestion system with 1 mL whole blood for 8 minutes. Amberlite IRC-718 resin was used as a solid phase in solid-liquid extraction technique for the removal of matrix interferences such as Na, S, P, and other polyatomic ion species. Detection limits for Cu, Sn, and Bi by this method were 0.000375 ng/mL, 0.000297 ng/mL, and 0.000174 ng/mL, respectively. Recoveries of 99.1% for Cu, 102.5% for Sn, and 98.4% for Bi were obtained for the standard spiked NIST SRM 955a blood sample. The developed method was applied for whole real blood and urine samples.

  • PDF

Analysis of oligosaccharides from Panax ginseng by using solid-phase permethylation method combined with ultra-high-performance liquid chromatography-Q-Orbitrap/mass spectrometry

  • Li, Lele;Ma, Li;Guo, Yunlong;Liu, Wenlong;Wang, Yang;Liu, Shuying
    • Journal of Ginseng Research
    • /
    • v.44 no.6
    • /
    • pp.775-783
    • /
    • 2020
  • Background: The reports about valuable oligosaccharides in ginseng are quite limited. There is an urgent need to develop a practical procedure to detect and analyze ginseng oligosaccharides. Methods: The oligosaccharide extracts from ginseng were permethylated by solid-phase methylation method and then were analyzed by ultra-high-performance liquid chromatography-Q-Orbitrap/MS. The sequence, linkage, and configuration information of oligosaccharides were determined by using accurate m/z value and tandem mass information. Several standard references were used to further confirm the identification. The oligosaccharide composition in white ginseng and red ginseng was compared using a multivariate statistical analysis method. Results: The nonreducing oligosaccharide erlose among 12 oligosaccharides identified was reported for the first time in ginseng. In the comparison of the oligosaccharide extracts from white ginseng and red ginseng, a clear separation was observed in the partial least squares-discriminate analysis score plot, indicating the sugar differences in these two kinds of ginseng samples. The glycans with variable importance in the projection value large than 1.0 were considered to contribute most to the classification. The contents of oligosaccharides in red ginseng were lower than those in white ginseng, and the contents of maltose, maltotriose, maltotetraose, maltopentaose, maltohexaose, maltoheptaose, maltooctaose, maltononaose, sucrose, and erlose decreased significantly (p < 0.05) in red ginseng. Conclusion: A solid-phase methylation method combined with liquid chromatography-tandem mass spectrometry was successfully applied to analyze the oligosaccharides in ginseng extracts, which provides the possibility for holistic evaluation of ginseng oligosaccharides. The comparison of oligosaccharide composition of white ginseng and red ginseng could help understand the differences in pharmacological activities between these two kinds of ginseng samples from the perspective of glycans.

Application of TAO System and RDF for Treatment of Cattle Manure (우분뇨의 고형연료화와 고온호기산화 공정 적용 가능성에 관한 연구)

  • Kim, Soo-Ryang;Hong, In-Gi;Kim, Ha-Je;Jeon, Sang-Jun;Lee, Jeong-Soo;Lee, Myung-Gyu
    • Journal of Animal Environmental Science
    • /
    • v.19 no.2
    • /
    • pp.177-182
    • /
    • 2013
  • We studied the possibility to produce solid fuel using cattle manure and to apply TAO (Thermophilic Aerobic Oxidation) process of solid-liquid separation fraction. The physiochemical compositions of cattle manure solid fuel chip were analyzed as water 0.12%, low calorific value 3,510 kcal/kg, ashes 11.9%, chlorine 0.82%, sulfur dust 0.5%, mercury non-detection, cadmium 1.0 mg/kg, lead 2 mg/kg, arsenic non-detection. In treating cattle manure with TAO reactor the internal temperature of the reactor was increasing higher and $50^{\circ}C$ and over was maintained after 20 hours on. The physiochemical compositions of liquids increased from pH 7.3 to pH 9.18 and EC decreased from 4.6 to 3.48 mS/cm in treating process of cattle manure with TAO reactor. COD and SCOD decreased from 16,800 to 10,400 mg/L, from 4,600 to 2,040 mg/L respectively, which showed about 38% and 56% of remove efficiency respectively.

Optimizing of Coagulation and Solid-Liquid Separation Conditions Using Aluminum Sulfate and Poly-Aluminum Chloride Coagulants from Brine Wastewater Discharged by the Epoxy-resin Process (에폭시수지 공정에서 발생되는 고염 폐수로부터 황산알루미늄과 PAC 응집제를 이용한 응집/고액분리 조건 최적화)

  • Lee, Chang-Han;Kim, Yu-Jin;Moon, Sung-Hyun;Kwon, Sung-Hun;Ahn, Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In this study, solid-liquid separation conditions for coagulation and sedimentation experiments using inorganic coagulant (aluminum sulfate and Poly-Aluminum Chloride (PAC)) were optimized with brine wastewater discharged by the epoxy-resin process. When the turbidity and suspended solid (SS) concentration in raw wastewater were 74 NTU and 4.1 mg/L, respectively, their values decreased the lowest in a coagulant dosage of 135.0 - 270.0 mg Al3+/L. The epoxy resin was re-dispersed in the upper part of wastewater treated above 405.0 mg Al3+/L. The removal efficiencies of turbidity and SS via dosing with aluminum sulfate and PAC were evaluated at initial turbidity and SS of 74 - 630 NTU and 4.1 - 38.5 mg/L, respectively. They increased most in the range from 135.0 - 270.0 mg Al3+/L. The solid-liquid separation condition was quantitatively compared to the correlation of SS removal efficiency between the coagulant dosage and SS concentration based on the concentration of aluminum ions. The empirical formula, R = beaD, shows the relationship between SS removal efficiency (R) and coagulant dosage (D) at 38.5 mg/L; it produced high correlation coefficients (r2) of 0.9871 for aluminum sulfate and 0.9751 for PAC.