• 제목/요약/키워드: Liquid-phase reduction

검색결과 172건 처리시간 0.027초

NiZn 페라이트의 저온 소결 특성에 관한 연구 (A Study on Properties of Low Temperature Sintering in the NiZn Ferrite System)

  • 고상기;김병호;김경용
    • 한국세라믹학회지
    • /
    • 제34권10호
    • /
    • pp.1074-1082
    • /
    • 1997
  • Microstructure and permeability as a function of sintering temperature and composition were studied on the Ni$\delta$Cu0.4-$\delta$Zn0.6Fe2O4 ($\delta$=0, 0.1, 0.2, 0.3, 0.4) which was prepared by Cu2+ substitution for Ni2+ in Ni.0.4Zn0.6Fe2O4, then followed by 8 wt% CuO and 1wt% Bi2O3 as sintering aids. It was found that NiCuZn ferrite in which Cu2+ is substituted for Ni2+ is more effective in reduction of sintering temperature than Ni.0.4Zn0.6Fe2O4, containing CuO as a sintering aid. The specimen $\delta$=0.2 sintered at 90$0^{\circ}C$ for 2hr exhibited the highest initial permeability value ($\mu$o=280 at 1Mhz), but the real permeability decreased at the frequency under 10 MHz. EPMA analysis showed that Ni$\delta$Cu0.4-$\delta$Zn0.6Fe2O4 ($\delta$=0.4), sintered at 95$0^{\circ}C$ for 2hrs consisted of three phase regions of Ni.0.3Cu0.1Zn0.6Fe2O4 region, Cu and Bi liquid existed at the 3-point boundary, although the stabilization energy of Ni2+ is higher than that of Cu2+ in B site.

  • PDF

실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구 (Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor)

  • 동종인;구우회;임대현
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

보론과 카본 조제를 사용한 AlN-SiC-TiB2계의 고온가압 및 Spark Plasma Sintering (Hot Pressing and Spark Plasma Sintering of AlN-SiC-TiB2 Systems using Boron and Carbon Additives)

  • 이세훈;김해두
    • 한국세라믹학회지
    • /
    • 제46권5호
    • /
    • pp.467-471
    • /
    • 2009
  • Effects of boron and carbon on the densification and thermal decomposition of an AlN-SiC-$TiB_2$ system were investigated. $SiO_2$ was mostly removed by the addition of carbon, while $Al_2O_3$ formed $Al_4O_4C$ and promoted the densification of the systems above $1850^{\circ}C$. Rather porous specimens were obtained without the additives after hot pressing at $2100^{\circ}C$, while densification was mostly completed at $2000^{\circ}C$ by using the additives. The sintering temperature decreased further to $1950^{\circ}C$ by applying spark plasma sintering. The additives promoted the shrinkage of AlN by forming a liquid phase which was originated from the carbo- and boro-thermal reduction of $Al_2O_3$ and AlN.

A Study of the Relation Between Nozzle Geometry, Internal flow and Sprays Characteristics in Diesel Fuel Injection Systems

  • Payri, Raul;Molina, S.;Salvador, F.J.;Gimeno, J.
    • Journal of Mechanical Science and Technology
    • /
    • 제18권7호
    • /
    • pp.1222-1235
    • /
    • 2004
  • This study examines the influence of geometry on the internal flow and macroscopic behavior of the spray in Diesel nozzles. For this investigation, two bi-orifice nozzles were employed: one cylindrical and one conical. The first step is to use a non-destructive characterization method which is based on the production of silicone moulds so that the precise internal geometry of the two nozzles can be measured. At this stage the nozzles have been characterized dimensionally and therefore the internal flow can be studied using CFD calculations. The results gained from this experiment make it possible also to ascertain the critical cavitation conditions. Once the critical cavitation conditions have been identified, the macroscopic parameters of the spray can be studied in both cavitating and non-cavitating conditions using a test rig pressurized with nitrogen and with the help of a image acquisition system and image processing software. Consequently, research can be carried out to determine the influence that cavitation has on macroscopic spray behavior. From the point of view of the spray macroscopic behavior, the main conclusion of the paper is that cavitation leads to an increment of the spray cone angle. On the other hand, from the point of view of the internal flow, the hole outlet velocity increases when cavitation appears. This phenomenon can be explained by the reduction in the cross section of the liquid phase in the outlet section of the hole.

Identification of 1-Furan-2-yl-3-pyridin-2-yl-propenone, an Anti-inflammatory Agent, and Its Metabolites in Rat Liver Subcellular Fractions

  • Lee, Sang-Kyu;Jeon, Tae-Won;Basnet, Arjun;Jeong, Hye-Gwang;Lee, Eung-Seok;Jeong, Tae-Cheon
    • Archives of Pharmacal Research
    • /
    • 제29권11호
    • /
    • pp.984-989
    • /
    • 2006
  • 1-Furan-2-yl-3-pyridin-2-yl-propenone (FPP-3) has been characterized to have an anti-inflammatory activity through the inhibition of the production of nitric oxide and tumor necrosis $factor-{\alpha}$. In the present studies, the phase 1 metabolism of FPP-3 was investigated in rat liver microsomes and cytosols. When FPP-3 was incubated with rat liver microsomes and cytosols in the presence of NADPH. 2 major peaks were detected on a liquid chromatography/electrospray ionization-mass spectrometry. Two metabolites (i.e., M1 and M2) were characterized as reduced forms on propenone: M1 (1-furan-2-yl-3-pyridin-2-yl-propan-1-one) was the initial metabolite and M2 (1-furan-2-yl-3-pyridin-2-yl-propan-1-ol) was a secondary alcohol believed to be formed from M1.

Development of a Fluorescent Sensor Based on Resazurin and Hydrotalcite for the Determination of Ethanol in Alcoholic Beverages

  • Hong Dinh Duong;Juyeon Kim;Jong Il Rhee
    • 센서학회지
    • /
    • 제33권2호
    • /
    • pp.70-77
    • /
    • 2024
  • In this study, a fluorescent ethanol sensor is developed to determine the ethanol concentration in the liquid phase. The sensor is developed using a complex of resazurin (RA)/resorufin (RO) and a hydrotalcite (HT) catalyst in a sol-gel matrix of methyltrimethoxysilane (MTMS) to produce a fluorescent ethanol-sensing membrane (RA/RO*HT membrane). The operation mechanism of the RA/RO*HT membrane is based on (i) the oxidation of ethanol to acetaldehyde and (ii) the reduction of RA to RO, through electron flows followed by EtOH ↔ HT ↔ RA/RO ↔ EtOH interactions. These possible redox reactions can lead to an increased fluorescence intensity of the RA/RO*HT membrane as the ethanol concentration increases. The RA/RO*HT membrane shows a linear detection range of 1-20 vol.% EtOH with limit of detection (LOD) of 0.178%. Additionally, the RA/RO*HT membrane has high sensitivity and accuracy for determining the alcohol content in several Korean alcoholic beverages.

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2006년도 추계학술대회
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

SCR 폐촉매 침출액으로부터 습식제련법에 의한 바나듐, 텅스텐의 회수 (Recovery of the Vanadium and Tungsten from Spent SCR Catalyst Leach Solutions by Hydrometallurgical Methods)

  • 최인혁;문경혜;전종혁;이진영;라제쉬 쿠마 죠티
    • 자원리싸이클링
    • /
    • 제29권2호
    • /
    • pp.62-68
    • /
    • 2020
  • 2000년대에 접어들면서 선택적 촉매 환원(SCR) 촉매에 대한 광범위한 수요가 점차 증가하고 있다. SCR 촉매는 환경보호를 위해 질소산화물(NOx)의 배출 방지에 사용 된다. 일반적으로 SCR 촉매의 주성분은 TiO2(70~80 %), WO3(7~10 %), V2O5(~1 %) 등으로 구성되어있다. SCR 폐촉매는 대개 매립되어 폐기 되는데, 분해도가 극히 낮아 매립지에 영구적으로 남아있게 된다는 문제점을 가지고 있다. 따라서 환경을 보호하고 페촉매에 함유되어 있는 유가금속의 회수를 위하여 새로운 첨단기술의 개발이 필요하다. 이러한 SCR 폐촉매의 처리를 위해 침출 및 액-액 추출과 같은 습식제련법이 설계되고 개발되었다. 첫 번째 단계에서 SCR 폐촉매로부터 바나듐과 텅스텐을 선택적으로 침출한 후, 액-액 추출 공정에 의해 처리되었다. 바나듐과 텅스텐의 선택적 추출을 위해 D2EHPA, PC 88A, TBP, Cyanex 272, Aliquat 336과 같은 다양한 상용 용매추출제를 이용한 실험을 수행하였다. 바나듐과 텅스텐의 추출 및 분리를 위해 세정(scrubbing) 및 탈거(stripping) 연구가 수행되고 최적화 되었다. 3상의 생성을 억제하기 위해 iso-decanol 시약을 사용하여 최적화 하였다.

냉각수 순환 방식 가열원 형상에 따른 요소수 해동 특성에 관한 수치적 연구 (Numerical Investigation of the Urea Melting and Heat Transfer Characteristics with Three Different Types of Coolant Heaters)

  • 이승엽;김만영;이천환;박윤범
    • 한국자동차공학회논문집
    • /
    • 제20권4호
    • /
    • pp.125-132
    • /
    • 2012
  • Urea-SCR system, which converts nitrogen oxides to nitrogen and water in the presence of a reducing agent, usually AdBlue urea solution, is known as one of the powerful NOx reduction systems for mobile as well as stationary applications. For its consistent and reliable operation in mobile applications, such various problems as transient injection, ammonia slip, and freezing in cold weather have to be resolved. In this work, therefore, numerical study on three-dimensional unsteady heating problems were analyzed to understand the melting and heat transfer characteristics such as urea liquid volume fraction, temperature profiles and generated natural convection behavior in urea solution by using the commercial software Fluent 6.3. After validating by comparing numerical and experimental data with pure gallium melting phenomena, numerical experiment for urea melting is conducted with three different coolant heating models named CH1, 2, and 3, respectively. Finally, it can be found that the CH3 model, in which more coolant is concentrated on the lower part of the urea tank, has relatively better melting capability than others in terms of urea quantity of $1{\ell}$ for start-up schedule.

TCE 오염 지하수의 정화를 위한 나노영가철 기반 반응존 공법의 현장 적용성 연구 (Field Study on Application of Reactive Zone Technology Using Zero-Valent Iron Nanoparticles for Remediation of TCE-Contaminated Groundwater)

  • 안준영;김철용;황경엽;전성천;황인성
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권6호
    • /
    • pp.80-90
    • /
    • 2014
  • The laboratory and field studies were conducted to identify an optimal injection concentration of nanoscale zero-valent iron particles (NZVI) and to evaluate the applicability of NZVI-based reactive zone technology to the site contaminated with trichloroethylene (TCE) DNAPL (Dense Non-Aqueous Phase Liquid). The laboratory test found an optimal injection concentration of NZVI of 5 g/L that could remove more than 95% of 0.15 mM TCE within 20 days. Eleven test wells were installed at the aquifer that was mainly composed of alluvial and weathered soils at a strong oxic condition with dissolved oxygen concentration of 3.50 mg/L and oxidation-reduction potential of 301 mV. NZVI of total 30 kg were successfully injected using a centrifugal pump. After 60 days from the NZVI injection, 86.2% of the TCE initially present in the groundwater was removed and the mass of TCE removed was 405 g. Nonchlorinated products such as ethane and ethene were detected in the groundwater samples. Based on the increased chloride ion concentration at the site, the mass of TCE removed was estimated to be 1.52 kg. This implied the presence of DNAPL TCE which contributed to a higher estimate of TCE removal than that based on the TCE concentration change.