• Title/Summary/Keyword: Liquid-gas 2-phase flame

Search Result 8, Processing Time 0.024 seconds

Application of DFB Diode Laser Sensor to Reacting Flow (II) - Liquid-Gas 2-Phase Reacting Flow -

  • Park, Gyung-Min;Masashi Katsuki;Kim, Duck-Jool
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.139-145
    • /
    • 2003
  • Diode laser sensor is conducted to measure the gas temperature in the liquid-gas 2-phase counter flow flame. C$\_$10/H/ sub 22/ and city gas were used as liquid fuel and gas fuel, respectively. Two vibrational overtones of H$_2$O were selected and measurements were carried out in the spray flame region stabilized the above gaseous premixed flame. The path-averaged temperature measurement using diode laser absorption method succeeded in the liquid fuel combustion environment regardless of droplets of wide range diameter. The path-averaged temperature measured in the post flame of liquid-gas 2-phase counter flow flame showed qualitative reliable results. The successful demonstration of time series temperature measurement in the liquid-gas 2-phase counter flow flame gave us motivation of trying to establish the effective control system in practical combustion system. These results demonstrated the ability of real-time feedback from combustor inside using the non-intrusive measurement as well as the possibility of application to practical combustion system. Failure case due to influence of spray flame was also discussed.

Temperature measurement of the spray flame using micro scale absorption bands and line strength (마이크로 스케일의 흡수선과 흡수강도를 이용한 분무화염의 온도측정)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2002
  • It is necessary to develope a high frequency diode laser sensor system based on the absorption spectroscopy for the measurement of temperature of the spray flame. DFB diode laser operating near $2.0{\mu}m$ was used to scan over selected $H_2O$ transitions near $1.9{\mu}m\;and\;2.2{\mu}m$, respectively. The measurement sensitivity at wide range of sweep frequency was evaluated using multi-pass cell containing $CO_2$ gas. This diode laser absorption sensor with high temporal resolution up to 10kHz was applied to measure the gas temperature in the spray flame region of liquid-gas 2-phase counter flow flame. The successful demonstration of time series temperature measurement in the spray flame gives us motivation of trying to establish non-intrusive temperature measurement method in the practical spray flame.

  • PDF

Fire-Protective Coating for Polymer Construction Materials using Two-dimensional Nanomaterials (2차원 나노소재를 활용한 고분자 건축자재의 난연코팅기술 개발)

  • Kim, Hanim
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.183-190
    • /
    • 2024
  • An environmentally-friendly nanocoating method that effectively adds flame retardant(FR) and gas shielding properties to combustible polymeric construction materials such as flexible polyurethane (PU) foam was studied. Naturally-driven two-dimensional(2D) nanomaterials such as graphene oxide (GO) can exhibit liquid crystalline (LC) properties in aqueous solutions, enabling uniform coatings on the various substrates including 3D-porous foams. LC phase-assisted coating serves as 3D-scaffold, facilitating the introduction of small molecules having antioxidant capabilities such as dopamine which is to form uniformly stacked FR coating. Additionally, the structural characteristics of the 2D-materials can effectively hinder the migration of toxic gases and flammable substances in the gas phase generated during combustion. This LC phase flame retardant coating technology could be a new approach to provide environmentally friendly and effective flame retardant and gas barrier properties to various types of polymeric materials.

Time Lag Analysis Using Phase of Flame Transfer Function (화염전달함수의 위상차를 이용한 시간지연 분석)

  • Pyo, Yeongmin;Kim, Jihwan;Kim, Daesik
    • Journal of ILASS-Korea
    • /
    • v.21 no.2
    • /
    • pp.104-110
    • /
    • 2016
  • Main purpose of the current paper is to show results of time lag analysis using phase information of flame transfer function in order to predict combustion instabilities in a gas turbine combustor. The flame transfer function (FTF) is modeled using a commercial Computational Fluid Dynamics (CFD) code (Fluent). Comparisons of the modeled flame shapes with the measured ones were made using the optimized heat transfer conditions and combustion models. The FTF modeling results show a quite good agreement with the measurement data in predicting the phase delay (i.e. time lag). Time lag analysis results using the phase of FTF shows better combustion instability prediction accuracy than using time lag calculated from the steady state flame length.

Optimization Condition of Trace Analysis of Fuel Oxygenated Compounds Using The Design of Experiment (DOE) in Solid-Phase Microextraction with GC/FID (고체상미량분석법(SPME-GC/FID)에서 실험계획법을 이용한 연료첨가제 미량분석의 최적조건)

  • An, Sang-Woo;Lee, Si-Jin;Chang, Soon-Woong
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • In this study, Solid-phase micro-extraction (SPME) with Gas Chromatograph using Flame Ionization Detector (GC/FID) was studied as a possible alternative to liquid-liquid extraction for the analysis of Methyl tert-butyl ether (MTBE) and Tertiary-butyl ether (TBA) in water and an optimization condition of trace analysis of MTBE and TBA using the design of experiment (DOE) was described. The aim of our research was to apply experimental design methodology in the optimization condition of trace analysis of fuel oxygenated compounds in soil-phase microextraction with GC/FID. The reactions of SPME were mathematically described as a function of parameters of Temp ($X_1$), Volume ($X_2$), Time ($X_3$) and Salt ($X_4$) being modeled by the use of the partial factorial designs, which was used for fitting 2nd order response surface models and was alternative to central composite designs. The model predicted agreed with the experimentally observed result ($Y_1$(MTBE, $R^2$ = 0.96, $Y_2$ (TBA, $R^2$ = 0.98)). The estimated ridge of the expected maximum responses and optimal conditions for MTBE and TBA were 278.13 and (Temp ($X_1$) = $48.40^{\circ}C$, Volume ($X_2$) = 73.04 mL, Time ($X_3$) = 11.51 min and Salt ($X_4$) = 12,50 mg/L), and 127.89 and (Temp ($X_1$) = $52.12^{\circ}C$, Volume ($X_2$) = 88.88mL, Time ($X_3$) = 65.40 min and Salt ($X_4$) = 12,50 mg/L), respectively.

Quantitative Determination of Ascaridole, Carvacrol and p-Cymene in the Biopesticides Products Derived from Chenopodium ambrosioides L. Extracts by Gas Chromatography

  • Yang, Ji-Yeon;Ryu, Song-Hee;Lim, Sung-Jin;Choi, Geun-Hyoung;Park, Byung-Jun
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.3
    • /
    • pp.211-215
    • /
    • 2016
  • BACKGROUND: The commercial biopesticides containing Chenopodium ambrosioides L. extracts which have been registered as one of the ingredients of the commercial biopesticide by the organic agriculture materials, and have been widely used in Republic of Korea. However, the quantitative analysis method of the active substances for the commercial biopesticides containing C. ambrosioides L. extract has not been conducted.METHODS AND RESULTS: To analyze the quantitative analysis of ascaridole, carvacrol, and p-cymene as active substances of C. ambrosioides L. extract, hydrophilic lipophilic balance cartridge was used for solid phase extraction. The active substances were analyzed by the gas chromatography with flame ionization detector. The limit of quantitation values of ascaridole, carvacrol, and p-cymene were 10, 5, and 2 mg/L, and the recovery rates were 96.3, 84.0, and 82.5% in liquid products and 98.3, 99.1, and 97.3% in solid products, respectively. The total content of ascaridole, carvacrol, and p-cymene in the commercial biopesticides was ranged from 0.08 to 12.75%.CONCLUSION: From these results, this method was suitable for the quantitative analysis of the active substances of commercial biopesticides containing C. ambrosioides L. extract.

A Study on the Combustion Characteristic in Hybrid Rocket Motor using PE/$LN_2O$ (PE/$LN_2O$ 하이브리드 로켓 모터의 연소특성에 관한 연구)

  • Kim, Gi-Hun;Lee, Jung-Pyo;Kim, Soo-Jong;Cho, Jung-Tae;Kim, Hak-Chul;Woo, Kyoung-Jin;Sung, Hong-Gye;Moon, Hee-Jang;Kim, Jin-Kon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.233-236
    • /
    • 2009
  • In this study, the characteristic of the hybrid rocket motor with $LN_2O$(Liquid Nitrous oxide) was investigated experimentally. HDPE(High Density PolyEthlene) was used as fuel with different sized single port. When used $LN_2O$, combustion efficiency is lower than using $GN_2O$(Gas Nitrous oxide), because of completeness of vaporization of droplet and mixing. And regression rate was changed by different oxidizer phase. This behavior was considered that flame temperature and combustion of solid fuel front/end surface.

  • PDF

Quantitative Analysis of Cystic Fluid Components in Cysticercus cellulosae (유구낭미충(有鉤囊尾蟲) 낭액(囊液)의 아미노산(酸) 및 유리지방산(遊離脂肪酸)의 정량분석(定量分析))

  • Moon, Joon;Chung, Myung-Sook;Joo, Kyoung-Hwan;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.16 no.2
    • /
    • pp.141-153
    • /
    • 1991
  • Free amino acid(FAA), free fatty acid(FFA), and amino acid obtained by hydrolysis of protein components of cystic fluid(CF) of Cysticercus cellulosae in pig and man were analyzed. FFA was analyzed by gas chromatography using Varian model 2700, and flame ionization detector with 6 feet${\times}$1/4inch glass column. Flow rate of $N_2$ was 30 ml/min, $H_2$ was 30 ml/min, air was 350 ml/min respectively and chart speed was 1 cm/min. Amino acid was analyzed by high performance liquid chromatography using Waters model 441, and fluorescence detector at 338nm/425nm with column of amino acid analyzer. Buffer A of mobile phase was pH 3.05 and pH of buffer B was 9.6 respectively. The results obtained were as follows : Seven FFAs containing 12~18 carbons were detected : Saturated fatty acids were lauric acid ($C_{12}$), myristic acid($C_{14}$), palmitic acid($C_{16}$), Stearic acid($C_{18}$). Unsaturated fatty acids were oleic acid($C_{12}^{=1}$), linoleic acid($C_{12}^{=2}$), and one unidentified fatty acid was detected. Generally much more quantity of FFA was determined in CF obtained from pig than that from man. FFA of the largest quantity was palmitic acid; 0.078 mg/ml. Eighteen FAAs were detected and the largest quantity was alanine. Ouantity of alanine was 386 ug/ml in CF from pig 108 ug/ml in CF from man respectively. while histidine in CF from pig was 273 ug/ml, that from man was only 4.3 ug/ml. Eighteen amino acids were identified by hydrolysis of protein in CF from man. But, histidine was not identified in CF from pig. Amino from pig and ug/ml from man.

  • PDF